Title: HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM: B1423; Open in Pressure Sensor Circuit / Abnormal Refrigerant Pressure; 2021 - 2024 MY Camry HV [10/2020 - ] |
DTC
|
B1423
|
Open in Pressure Sensor Circuit / Abnormal Refrigerant Pressure
|
DESCRIPTION
This DTC is stored if refrigerant pressure on the high pressure side is extremely low (196 kPaG (2.0 kgf/cm2, 28 psi) or less) or extremely high (2812 kPaG (28.7 kgf/cm2, 408 psi) or more). The air conditioner pressure sensor, which is installed to the high pressure side pipe to detect refrigerant pressure, sends a refrigerant pressure signal to the air conditioning amplifier assembly. The air conditioning amplifier assembly converts this signal to a pressure value according to the sensor characteristics and uses it to control the compressor.
DTC No.
|
Detection Item
|
DTC Detection Condition
|
Trouble Area
|
Memory
|
B1423
|
Open in Pressure Sensor Circuit / Abnormal Refrigerant Pressure
|
-
Open or short in air conditioner pressure sensor circuit
-
Refrigerant pressure on high pressure side is extremely low (196 kPaG (2.0 kgf/cm2, 28 psi) or less) or extremely high (2812 kPaG (28.7 kgf/cm2, 408 psi) or more)
|
-
Air conditioner pressure sensor
-
Harness or connector
-
Air conditioning amplifier assembly
-
Cooler expansion valve (blocked, stuck)
-
Cooler condenser assembly (blocked, deterioration of cooling capacity due to dirt)
-
Cooler dryer (moisture in the refrigerant cycle cannot be absorbed)
-
Cooling fan system (cooler condenser assembly cannot be cooled down)
-
Air conditioning system (leaks, blocked)
-
Refrigerant volume (excessive, low)
|
-
|
WIRING DIAGRAM
CAUTION / NOTICE / HINT
NOTICE:
-
Be sure to check the refrigerant volume first when this DTC is output because this DTC can also be stored if there is no refrigerant in the cycle.
Click here
-
If DTC B1423 and B14B8 are output at the same time, troubleshoot for DTC B14B8 first.
Click here
HINT:
Make sure that the connector is properly connected. If it is not, securely connect it and check for DTCs again.
PROCEDURE
(a) Check for DTCs.
Body Electrical > Air Conditioner > Trouble Codes
Result
|
Proceed to
|
B14B8 is not output
|
A
|
B14B8 is output
|
B
|
A
|
|
|
2.
|
COMPARE REFRIGERANT GAS PRESSURE VALUES SHOWN ON TECHSTREAM AND MANIFOLD GAUGE SET
|
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Air Conditioner / Data List.
(e) Read the Data List according to the display on the Techstream.
Body Electrical > Air Conditioner > Data List
Tester Display
|
Measurement Item
|
Range
|
Normal Condition
|
Diagnostic Note
|
Regulator Pressure Sensor
|
Air conditioner pressure sensor
|
Min.: -456.68 kPaG
Max.: 3294.37 kPaG
|
Actual refrigerant pressure displayed
|
-
Refrigerant line (gas leak etc.)
-
Air conditioner pressure sensor circuit malfunction
|
Body Electrical > Air Conditioner > Data List
Tester Display
|
Regulator Pressure Sensor
|
(f) Install a manifold gauge set.
Click here
(g) Compare the values displayed in the Data List and on the manifold gauge set.
Result
|
Proceed to
|
Data List value and manifold gauge set value do not match and Data List value: 196 kPaG (2.0 kgf/cm2, 28 psi) or less
|
A
|
Data List value and manifold gauge set value do not match and Data List value: 2812 kPaG (28.7 kgf/cm2, 408 psi) or more
|
B
|
Data List value matches manifold gauge set value
|
C
|
A
|
|
|
3.
|
READ VALUE USING TECHSTREAM (REGULATOR PRESSURE SENSOR)
|
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Air Conditioner / Data List.
(e) Read the Data List according to the display on the Techstream.
Body Electrical > Air Conditioner > Data List
Tester Display
|
Measurement Item
|
Range
|
Normal Condition
|
Diagnostic Note
|
Regulator Pressure Sensor
|
Air conditioner pressure sensor
|
Min.: -456.68 kPaG
Max.: 3294.37 kPaG
|
Actual refrigerant pressure displayed
|
-
Refrigerant line (gas leak etc.)
-
Air conditioner pressure sensor circuit malfunction
|
Body Electrical > Air Conditioner > Data List
Tester Display
|
Regulator Pressure Sensor
|
OK:
Disconnecting the A18 connector of the air conditioner pressure sensor causes the Data List value to change.
Result
|
Proceed to
|
Regulator pressure sensor value changes
|
A
|
Regulator pressure sensor value does not change
|
B
|
A
|
|
|
4.
|
CHECK TERMINAL VOLTAGE (AIR CONDITIONER PRESSURE SENSOR)
|
(a) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
|
Condition
|
Specified Condition
|
A18-3 (+) - Body ground
|
Power switch on (IG)
|
4.75 to 5.25 V
|
|
|
*a
|
Front view of wire harness connector
(to Air Conditioner Pressure Sensor)
|
|
|
NG
|
|
|
5.
|
CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
|
(a) Disconnect the K55 air conditioning amplifier assembly connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
A18-3 (+) - K55-6 (S5-3)
|
Always
|
Below 1 Ω
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
6.
|
CHECK TERMINAL VOLTAGE (AIR CONDITIONING AMPLIFIER ASSEMBLY)
|
(a) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
|
Condition
|
Specified Condition
|
A18-2 (PR) - Body ground
|
Power switch on (IG)
|
3.0 to 5.25 V
|
|
|
*a
|
Front view of wire harness connector
(to Air Conditioner Pressure Sensor)
|
|
|
NG
|
|
|
7.
|
CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
|
(a) Disconnect the K55 air conditioning amplifier assembly connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
A18-2 (PR) or K55-24 (PRE) - Other terminals and body ground
|
Always
|
10 kΩ or higher
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
8.
|
CHECK HARNESS AND CONNECTOR
|
(a) Disconnect the A18 air conditioner pressure sensor connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
A18-1 (-) - Body ground
|
Always
|
Below 1 Ω
|
OK
|
|
|
9.
|
CHECK TERMINAL VOLTAGE
|
(a) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
|
Condition
|
Specified Condition
|
A18-2 (PR) - Body ground
|
Power switch on (IG)
|
3.0 to 5.25 V
|
|
|
*a
|
Front view of wire harness connector
(to Air Conditioner Pressure Sensor)
|
|
|
Result
|
Proceed to
|
5.25 V or higher
|
A
|
3.0 to 5.25 V
|
B
|
Below 3.0 V
|
C
|
A
|
|
|
10.
|
CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
|
(a) Disconnect the K55 air conditioning amplifier assembly connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
A18-2 (PR) or K55-24 (PRE) - Other terminals
|
Always
|
10 kΩ or higher
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
11.
|
CHECK INTERNAL CIRCUIT RESISTANCE (AIR CONDITIONING AMPLIFIER ASSEMBLY)
|
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
A18-3 (+) - A18-2 (PR)
|
Power switch off
|
180 to 220 kΩ
|
HINT:
After turning the power switch off, wait at least 30 seconds before performing the measurement.
NG
|
|
|
12.
|
CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
|
(a) Disconnect the K55 air conditioning amplifier assembly connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
A18-2 (PR) or K55-24 (PRE) - A18-3 (+) or K55-6 (S5-3)
|
Always
|
10 kΩ or higher
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
13.
|
CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
|
(a) Disconnect the K55 air conditioning amplifier assembly connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
A18-2 (PR) - K55-24 (PRE)
|
Always
|
Below 1 Ω
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
14.
|
CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
|
(a) Disconnect the K55 air conditioning amplifier assembly connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
A18-1 (-) - K55-3 (SG-4)
|
Always
|
Below 1 Ω
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
|