Last Modified: 11-20-2023 |
6.11:8.1.0 |
Doc ID: RM100000001KY87 |
Model Year Start: 2020 |
Model: Camry HV |
Prod Date Range: [09/2019 -
] |
Title: LIGHTING (EXT): LIGHTING SYSTEM (w/ AFS): B242F; Open in B Power Line; 2020 - 2024 MY Camry HV [09/2019 - ] |
DTC
|
B242F
|
Open in B Power Line
|
DESCRIPTION
The headlight ECU sub-assembly operates using the power source voltage input from the IG terminal and ECUB terminal.
The power source voltage of the ECUB terminal is supplied when the main body ECU (multiplex network body ECU) turns the ECUB power supply relay (H-LP LH relay and H-LP RH relay) to ON.
The headlight ECU sub-assembly compares the power source voltage supply condition of the IG terminal and ECUB terminal and monitors the result.
AFS
DTC No.
|
Detection Item
|
DTC Detection Condition
|
Trouble Area
|
DTC Output from
|
B242F
|
Open in B Power Line
|
Detection condition:
-
The power switch is on (IG).
Malfunction status:
-
No power source voltage supplied to ECUB terminal while power source voltage being supplied to IG terminal
|
-
Headlight ECU sub-assembly LH
-
Harness or connector
-
H-LP LH relay
-
Instrument panel junction block assembly
-
Main body ECU (multiplex network body ECU)
|
AFS
|
AFS (Sub)
DTC No.
|
Detection Item
|
DTC Detection Condition
|
Trouble Area
|
DTC Output from
|
B242F
|
Open in B Power Line
|
Detection condition:
-
The power switch is on (IG).
Malfunction status:
-
No power source voltage supplied to ECUB terminal while power source voltage being supplied to IG terminal
|
-
Headlight ECU sub-assembly RH
-
Harness or connector
-
H-LP RH relay
-
Main body ECU (multiplex network body ECU)
|
AFS (Sub)
|
WIRING DIAGRAM
CAUTION / NOTICE / HINT
PROCEDURE
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / AFS or AFS (Sub) / Trouble Codes.
(e) Clear the DTCs.
Body Electrical > AFS > Clear DTCs
Body Electrical > AFS (Sub) > Clear DTCs
NEXT
|
|
|
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Wait 10 seconds or more.
(d) Turn the Techstream on.
(e) Enter the following menus: Body Electrical / AFS or AFS (Sub) / Trouble Codes.
(f) Check for DTCs.
Body Electrical > AFS > Trouble Codes
Body Electrical > AFS (Sub) > Trouble Codes
OK:
DTC B242F is not output.
Result
|
Proceed to
|
OK
|
A
|
NG (DTC output from headlight ECU sub-assembly LH)
|
B
|
NG (DTC output from headlight ECU sub-assembly RH)
|
C
|
B
|
|
|
3.
|
INSPECT HEADLIGHT ECU SUB-ASSEMBLY LH (ECUB TERMINAL VOLTAGE)
|
*a
|
Front view of wire harness connector
(to Headlight ECU Sub-assembly LH)
|
(a) Disconnect the A79 headlight ECU sub-assembly LH connector.
(b) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
|
Condition
|
Specified Condition
|
A79-13 (ECUB) - Body ground
|
Power switch on (IG)
|
9.5 to 14 V
|
OK
|
|
|
4.
|
CHECK HARNESS AND CONNECTOR (HEADLIGHT ECU SUB-ASSEMBLY LH - BODY GROUND)
|
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
A79-12 (GND) - Body ground
|
Always
|
Below 1 Ω
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
(a) Inspect the H-LP LH relay.
Click here
NG |
|
REPLACE H-LP LH RELAY
|
OK
|
|
|
6.
|
CHECK HARNESS AND CONNECTOR (H-LP LH RELAY - HEADLIGHT ECU SUB-ASSEMBLY LH)
|
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
3 (H-LP LH relay) - A79-13 (ECUB)
|
Always
|
Below 1 Ω
|
3 (H-LP LH relay) or A79-13 (ECUB) - Body ground
|
Always
|
10 kΩ or higher
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
OK
|
|
|
7.
|
CHECK HARNESS AND CONNECTOR (POWER SOURCE - H-LP LH RELAY)
|
(a) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
|
Condition
|
Specified Condition
|
2 (H-LP LH relay) - Body ground
|
Power switch off
|
11 to 14 V
|
5 (H-LP LH relay) - Body ground
|
Power switch off
|
11 to 14 V
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
OK
|
|
|
8.
|
CHECK HARNESS AND CONNECTOR (H-LP LH RELAY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
|
(a) Disconnect the 3C instrument panel junction block assembly connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
1 (H-LP LH relay) - 3C-31
|
Always
|
Below 1 Ω
|
1 (H-LP LH relay) or 3C-31 - Body ground
|
Always
|
10 kΩ or higher
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
OK
|
|
|
9.
|
INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
|
*a
|
Component without harness connected
(Instrument Panel Junction Block Assembly)
|
-
|
-
|
(a) Remove the instrument panel junction block assembly.
Click here
(b) Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.
(c) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
3C-31 - MB-15 (HRLY)
|
Always
|
Below 1 Ω
|
10.
|
INSPECT HEADLIGHT ECU SUB-ASSEMBLY RH (ECUB TERMINAL VOLTAGE)
|
*a
|
Front view of wire harness connector
(to Headlight ECU Sub-assembly RH)
|
(a) Disconnect the A80 headlight ECU sub-assembly RH connector.
(b) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
|
Condition
|
Specified Condition
|
A80-13 (ECUB) - Body ground
|
Power switch on (IG)
|
9.5 to 14 V
|
OK
|
|
|
11.
|
CHECK HARNESS AND CONNECTOR (HEADLIGHT ECU SUB-ASSEMBLY RH - BODY GROUND)
|
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
A80-12 (GND) - Body ground
|
Always
|
Below 1 Ω
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
12.
|
INSPECT H-LP RH RELAY
|
(a) Inspect the H-LP RH relay.
Click here
NG |
|
REPLACE H-LP RH RELAY
|
OK
|
|
|
13.
|
CHECK HARNESS AND CONNECTOR (H-LP RH RELAY - HEADLIGHT ECU SUB-ASSEMBLY RH)
|
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
3 (H-LP RH relay) - A80-13 (ECUB)
|
Always
|
Below 1 Ω
|
3 (H-LP RH relay) or A80-13 (ECUB) - Body ground
|
Always
|
10 kΩ or higher
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
OK
|
|
|
14.
|
CHECK HARNESS AND CONNECTOR (POWER SOURCE - H-LP RH RELAY)
|
(a) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
|
Condition
|
Specified Condition
|
2 (H-LP RH relay) - Body ground
|
Power switch off
|
11 to 14 V
|
5 (H-LP RH relay) - Body ground
|
Power switch off
|
11 to 14 V
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
OK
|
|
|
15.
|
CHECK HARNESS AND CONNECTOR (H-LP RH RELAY - MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU))
|
(a) Disconnect the K52 main body ECU (multiplex network body ECU) connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
1 (H-LP RH relay) - K52-12 (HRY2)
|
Always
|
Below 1 Ω
|
1 (H-LP RH relay) or K52-12 (HRY2) - Body ground
|
Always
|
10 kΩ or higher
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
|