B1279
|
Lost Communication with Humidity/Rain Sensor LIN
|
Lost communication with air conditioning thermistor assembly
|
|
B1411
|
Room Temperature Sensor Circuit
|
Open or short in room temperature sensor circuit
|
|
B1412
|
Ambient Temperature Sensor Circuit
|
Open or short in ambient temperature sensor circuit
|
|
B1413
|
Evaporator Temperature Circuit or Evaporator Fin Thermistor
|
Open or short in evaporator temperature sensor circuit
|
|
B1423
|
Open in Pressure Sensor Circuit / Abnormal Refrigerant Pressure
|
-
Open or short in air conditioner pressure sensor circuit
-
for HFC-134a(R134a):
Refrigerant pressure on high pressure side is extremely low (176 kPaG (1.8 kgf/cm2, 26 psi) or less) or extremely high (3025 kPaG (30.8 kgf/cm2, 439 psi) or more)
-
for HFO-1234yf(R1234yf):
Refrigerant pressure on high pressure side is extremely low (196 kPaG (2.0 kgf/cm2, 28 psi) or less) or extremely high (2812 kPaG (28.7 kgf/cm2, 408 psi) or more)
|
|
B1441
|
Air Mix Damper Control Servo Motor Circuit (Passenger Side)
|
Air mix damper position sensor value does not change even if air conditioning amplifier assembly operates No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix)
|
|
B1442
|
Air Inlet Damper Control Servo Motor Circuit
|
Air inlet damper position sensor value does not change even if air conditioning amplifier assembly operates No. 1 blower damper servo sub-assembly
|
|
B1443
|
Air Outlet Damper Control Servo Motor Circuit
|
Air outlet damper position sensor value does not change even if air conditioning amplifier assembly operates No. 3 air conditioning radiator damper servo sub-assembly
|
|
B1446
|
Air Mix Damper Control Servo Motor Circuit (Driver Side)
|
Air mix damper position sensor value does not change even if air conditioning amplifier assembly operates No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix)
|
|
B1448
|
Passenger Side FACE Servo Motor Circuit
|
Air outlet damper position sensor value does not change even if air conditioning amplifier assembly operates No. 1 air conditioning radiator damper servo sub-assembly (front passenger side mode)
|
|
B1449
|
Air Outlet Damper Control Servo Motor Circuit (Rear)
|
Air outlet damper position sensor value does not change even if air conditioning amplifier assembly operates No. 2 air conditioning radiator damper servo sub-assembly
|
|
B1471
|
A/C Inverter High Voltage Power Resource System Malfunction
|
-
Open or short in A/C inverter high voltage power resource system
-
Boost inverter malfunctioning
|
|
B1472
|
A/C Inverter High Voltage Output System Malfunction
|
Open or short in A/C inverter high voltage output circuit
|
|
B1473
|
A/C Inverter Start-up Signal System Malfunction
|
Open or short in A/C inverter start-up signal circuit
|
|
B1474
|
A/C Inverter Malfunction
|
A/C inverter malfunction
|
|
B1475
|
A/C Inverter Cooling / Heating System Malfunction
|
A/C inverter temperature outside specified range (temperature too high) or open or short to ground in temperature sensor circuit
|
|
B1476
|
A/C Inverter Load System Malfunction
|
Motor rotation load while compressor is operating is too large or too small
|
|
B1477
|
A/C Inverter Low Voltage Power Resource System Malfunction
|
Open or short to ground in inverter control power voltage circuit
|
|
B1497
|
Communication Malfunction (Bus Ic)
|
Error or open in communication line
|
|
B1498
|
Communication Malfunction (A/C Inverter Local)
|
-
Error or open in communication line between the hybrid vehicle control ECU assembly and compressor with motor assembly
-
High-voltage power source shut off
|
|
B14A8
|
Glass Temperature Sensor Circuit
|
Open or short in glass temperature sensor circuit
|
|
B14A9
|
Glass Surroundings Temperature Sensor Circuit
|
Open or short in glass surroundings temperature sensor circuit
|
|
B14AA
|
Glass Humidity Sensor Circuit
|
Open or short in glass humidity sensor circuit
|
|
B14B2
|
Lost Communication with Front Panel LIN
|
Lost communication with air conditioning control assembly
|
|
B14B8
|
Refrigerant Shortage
|
The following condition is detected in the normal operation refrigerant shortage check:
Amount of refrigerant is insufficient
|
|
P1C7C49
|
Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure
|
High voltage system insulation malfunction
|
|
U0100
|
Lost Communication With ECM/PCM "A"
|
No communication with ECM
|
|
U0131
|
Lost Communication With Power Steering Control Module
|
No communication with power steering ECU (rack and pinion power steering gear assembly)
|
|
U0142
|
Lost Communication With Body Control Module "B"
|
No communication with main body ECU (multiplex network body ECU)
|
|
U0151
|
Lost Communication With Restraints Control Module
|
No communication with airbag sensor assembly
|
|
U0155
|
Lost Communication With Instrument Panel Cluster (IPC) Control Module
|
No communication with combination meter assembly
|
|
U0163
|
Lost Communication With Navigation Control Module
|
No communication with air conditioning control panel (radio and display receiver assembly)
|
|
U0293
|
Lost Communication with HV ECU
|
No communication with hybrid vehicle control ECU assembly
|
|