Last Modified: 11-20-2023 |
6.11:8.1.0 |
Doc ID: RM100000001EZN9 |
Model Year Start: 2019 |
Model: Camry HV |
Prod Date Range: [09/2018 - 10/2020] |
Title: HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM: A/C Switch Indicator does not Turn On; 2019 - 2020 MY Camry HV [09/2018 - 10/2020] |
A/C Switch Indicator does not Turn On
|
DESCRIPTION
If none of the switch indicators on the air conditioning control panel (radio and display receiver assembly)*1 or air conditioning control assembly*2 illuminate, the following factors may be the cause.
Symptom
|
Factor
|
A/C switch indicator does not illuminate
|
-
Air conditioning amplifier assembly malfunction
-
Air conditioning control panel (radio and display receiver assembly) malfunction*1
-
Air conditioning control assembly malfunction*2
-
A/C switch malfunction
-
A/C switch indicator malfunction (including when indicator turned off without switch operation)
-
Servo motor initialization (incomplete)
-
Mechanical locking of damper and damper link
-
Refrigerant pressure is extremely low
-
Low detected ambient temperature (including thermistor assembly malfunction)
|
-
*1: for 8 Inch Display
-
*2: for 7 Inch Display
PROCEDURE
Result
|
Proceed to
|
for 8 Inch Display
|
A
|
for 7 Inch Display
|
B
|
A
|
|
|
2.
|
CHECK AIR CONDITIONING CONTROL PANEL (RADIO AND DISPLAY RECEIVER ASSEMBLY)
|
(a) Check that the switch indicators on the air conditioning control panel (radio and display receiver assembly) illuminate immediately after the engine is started.
OK:
All switch indicators illuminate.
3.
|
CHECK AIR CONDITIONING CONTROL ASSEMBLY
|
(a) Check that the switch indicators on the air conditioning control assembly illuminate immediately after the engine is started.
OK:
All switch indicators illuminate.
OK
|
|
|
4.
|
READ VALUE USING TECHSTREAM
|
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Air Conditioner / Data List.
(e) Read the Data List according to the display on the Techstream.
Body Electrical > Air Conditioner > Data List
Tester Display
|
Measurement Item
|
Range
|
Normal Condition
|
Diagnostic Note
|
Ambient Temp Sensor
|
Thermistor assembly
|
Min.: -23.30°C (-9.94°F)
Max.: 65.95°C (150.71°F)
|
Actual ambient temperature displayed
|
Thermistor assembly circuit malfunction
-
When open circuit: -23.30°C (-9.94°F)
-
When short circuit: 65.95°C (150.71°F)
|
Body Electrical > Air Conditioner > Data List
Tester Display
|
Ambient Temp Sensor
|
OK:
The value displayed is 0°C (32°F) or higher.
OK |
|
INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET
for HFC-134a (R134a): Click here
for HFO-1234yf (R1234yf): Click here
|
|