Last Modified: 11-20-2023 6.11:8.1.0 Doc ID: RM1000000015DR8
Model Year Start: 2018 Model: Camry HV Prod Date Range: [07/2017 -           ]
Title: HYBRID / BATTERY CONTROL: HYBRID BATTERY SYSTEM (for LITHIUM-ION BATTERY): TERMINALS OF ECU; 2018 - 2024 MY Camry HV [07/2017 -        ]

TERMINALS OF ECU

*1

Battery ECU assembly

-

-

Terminal No.

(Symbols)

Wiring Color

Input/Output

Terminal Description

Condition

Specified Condition

z16-1 (AM) - z16-27 (GND)

BR - W-G

IN

Constant power source

Always

11 to 14 V

z16-27 (GND) - Body ground

W-G

Ground

Ground

Always

Below 1 Ω

z16-3 (GND1) - Body ground

GR

Ground

Ground

Always

Below 1 Ω

z16-4 (ERTH) - Body ground

LG

Ground

Ground

Always

Below 1 Ω

z16-18 (TB0) - z16-17 (GB0)

P - P

IN

Battery temperature sensor 0

Power switch on (IG)

HV battery temperature: -40 to 90°C (-40 to 194°F)

4.75 (-40°C) to 0.46 V(90°C)

z16-31 (TB1) - z16-30 (GB1)

Y - Y

IN

Battery temperature sensor 1

Power switch on (IG)

HV battery temperature: -40 to 90°C (-40 to 194°F)

4.75 (-40°C) to 0.46 V(90°C)

z16-7 (TB2) - z16-6 (GB2)

L - L

IN

Battery temperature sensor 2

Power switch on (IG)

HV battery temperature: -40 to 90°C (-40 to 194°F)

4.75 (-40°C) to 0.46 V(90°C)

z16-20 (TB3) - z16-19 (GB3)

LG - B

IN

Battery temperature sensor 3

Power switch on (IG)

HV battery temperature: -40 to 90°C (-40 to 194°F)

4.75 (-40°C) to 0.46 V(90°C)

z16-33 (TB4) - z16-32 (GB4)

GR - W-G

IN

Battery temperature sensor 4

Power switch on (IG)

HV battery temperature: -40 to 90°C (-40 to 194°F)

4.75 (-40°C) to 0.46 V(90°C)

z16-9 (TB5) - z16-8 (GB5)

R - W

IN

Battery temperature sensor 5

Power switch on (IG)

HV battery temperature: -40 to 90°C (-40 to 194°F)

4.75 (-40°C) to 0.46 V(90°C)

z16-22 (TC0) - z16-21 (GC0)

P-B - V

IN

Intake air temperature sensor

Power switch on (IG)

HV battery intake air temperature: -40 to 90°C (-40 to 194°F)

4.75 (-40°C) to 0.46 V(90°C)

z16-12 (IB0) - z16-23 (GIB)

BR- B-W

IN

Battery current sensor 0

Power switch on (IG)

Approximately 2.8 V

z16-24 (IB1) - z16-23 (GIB)

L-W - B-W

IN

Battery current sensor 1

Power switch on (IG)

Approximately 2.2 V

z16-36 (VIB) - z16-23 (GIB)

G - B-W

OUT

Power source for battery current sensor

Power switch on (IG)

4.5 to 5.5 V

z16-13 (IGCT) - z16-27 (GND)

L-W - W-G

IN

Power source

Power switch on (IG)

11 to 15.5 V

z16-14 (SI0) - z16-27 (GND)

P-B - W-G

OUT

HV battery cooling blower operation signal

Cooling fans operating

Pulse generation

(Waveform 1)

Cooling fans not operating

4.5 to 5.5 V

z16-15 (FP0) - z16-27 (GND)

V - W-G

IN

HV battery cooling blower monitor signal

Cooling fans operating

Pulse generation

(Waveform 2)

Cooling fans not operating

0 Hz

z16-25 (CA1H) - z16-27 (GND)

B - W-G

IN/OUT

CAN communication line

Power switch on (IG)

Pulse generation

(Waveform 3)

z16-26 (CA1L) - z16-27 (GND)

LG - W-G

IN/OUT

CAN communication line

Power switch on (IG)

Pulse generation

(Waveform 3)

z16-28 (CA2L) - z16-27 (GND)

W - W-G

IN/OUT

CAN communication line

Power switch on (IG)

Pulse generation

(Waveform 4)

z16-29 (CA2H) - z16-27 (GND)

R - W-G

IN/OUT

CAN communication line

Power switch on (IG)

Pulse generation

(Waveform 4)

z15-1 (GA0) - z15-13 (VA1)

V - P

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z15-13 (VA1) - z15-25 (VA2)

P - L

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z15-25 (VA2) - z15-2 (VA3)

L - W

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z15-2 (VA3) - z15-14 (VA4)

W - BR

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z15-14 (VA4) - z15-26 (VA5)

BR - W-G

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z15-26 (VA5) - z15-3 (VA6)

W-G - B

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z15-3 (VA6) - z15-15 (VA7)

B - P-B

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z15-15 (VA7) - z15-27 (VA8)

P-B - L-W

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z15-27 (VA8) - z15-4 (VA9)

L-W - LG

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z15-4 (VA9) - z15-16 (VA10)

LG - B-W

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z15-16 (VA10) - z15-28 (VA11)

B-W - Y

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z15-28 (VA11) - z15-5 (VA12)

Y - G

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z15-5 (VA12) - z15-17 (VA13)

G - GR

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z15-17 (VA13) - z15-29 (VA14)

GR - V

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z15-29 (VA14) - z15-6 (VA15)

V - R

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z15-6 (VA15) - z15-18 (VA16)

R - L

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z15-18 (VA16) - z15-30(VA17)

L - P

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z15-30(VA17) - z15-7 (VA18)

P - BR

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z15-7 (VA18) - z15-19 (VA19)

BR - W

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z15-19 (VA19) - z15-31 (VA20)

W - B

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z15-31 (VA20) - z15-8 (VA21)

B - W-G

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z15-8 (VA21) - z15-20(VA22)

W-G - L-W

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z15-20(VA22) - z15-32 (VA23)

L-W - P-B

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z15-32 (VA23) - z15-9 (VA24)

P-B - B-W

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z15-9 (VA24) - z15-21 (VA25)

B-W - LG

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z15-21 (VA25) - z15-33 (VA26)

LG - G

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z15-33 (VA26) - z15-10(VA27)

G - Y

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z15-10(VA27) - z15-22 (VA28)

Y - V

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z15-22 (VA28) - z15-34 (VA29)

V - GR

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z15-34 (VA29) - z15-11 (VA30)

GR - L

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z15-11 (VA30) - z15-23 (VA31)

L - R

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z15-23 (VA31) - z15-35 (VA32)

R - BR

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z15-35 (VA32) - z15-12 (VA33)

BR - P

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z15-12 (VA33) - z15-24 (VA34)

P - B

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z15-24 (VA34) - z15-36 (VA35)

B - W

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z11-1 (VAD) - z11-13 (VA36)

W - B

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z11-13 (VA36) - z11-25 (VA37)

B - P

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z11-25 (VA37) - z11-2 (VA38)

P - BR

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z11-2 (VA38) - z11-14 (VA39)

BR - R

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z11-14 (VA39) - z11-26 (VA40)

R - L

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z11-26 (VA40) - z11-3 (VA41)

L - GR

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z11-3 (VA41) - z11-15 (VA42)

GR - V

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z11-15 (VA42) - z11-27 (VA43)

V - Y

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z11-27 (VA43) - z11-4 (VA44)

Y - G

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z11-4 (VA44) - z11-16 (VA45)

G - LG

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z11-16 (VA45) - z11-28 (VA46)

LG - B-W

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z11-28 (VA46) - z11-5 (VA47)

B-W - P-B

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z11-5 (VA47) - z11-17 (VA48)

P-B - L-W

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z11-17 (VA48) - z11-29 (VA49)

L-W - W-G

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z11-29 (VA49) - z11-6 (VA50)

W-G - B

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z11-6 (VA50) - z11-18 (VA51)

B - W

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z11-18 (VA51) - z11-30(VA52)

W - BR

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z11-30(VA52) - z11-7 (VA53)

BR - P

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z11-7 (VA53) - z11-19 (VA54)

P - L

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z11-19 (VA54) - z11-31 (VA55)

L - R

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z11-31 (VA55) - z11-8 (VA56)

R - V

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z11-8 (VA56) - z11-20(VA57)

V - GR

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z11-20(VA57) - z11-32 (VA58)

GR - G

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z11-32 (VA58) - z11-9 (VA59)

G - Y

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z11-9 (VA59) - z11-21 (VA60)

Y - B-W

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z11-21 (VA60) - z11-33 (VA61)

B-W - LG

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z11-33 (VA61) - z11-10(VA62)

LG - L-W

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z11-10(VA62) - z11-22 (VA63)

L-W - P-B

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z11-22 (VA63) - z11-34 (VA64)

P-B - B

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z11-34 (VA64) - z11-11 (VA65)

B - W-G

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z11-11 (VA65) - z11-23 (VA66)

W-G - BR

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z11-23 (VA66) - z11-35 (VA67)

BR - W

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z11-35 (VA67) - z11-12 (VA68)

W - L

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z11-12 (VA68) - z11-24 (VA69)

L - P

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

z11-24 (VA69) - z11-36 (VA70)

P - V

IN

Hybrid Battery Cell Voltage

Always

1.9 to 4.1 V

Oscilloscope waveforms

HINT:

Oscilloscope waveform samples are provided here for informational purposes. Noise and fluttering waveforms have been omitted.

(a) Waveform 1 (HV battery cooling blower operation signal)

Item

Content

Terminal

z16-14 (SI0) - z16-27 (GND)

Equipment Setting

10 V/DIV., 1 ms/DIV.

Condition

Cooling fans operating

HINT:

The wavelength will vary with the operating speed of the battery cooling blower assembly.

(b) Waveform 2 (HV battery cooling blower monitor signal)

Item

Content

Terminal

z16-15 (FP0) - z16-27 (GND)

Equipment Setting

2 V/DIV., 2 ms/DIV.

Condition

Battery cooling blower assembly operating (Active Test of cooling fan being performed)

HINT:

The wavelength will vary with the operating speed of the battery cooling blower assembly.

(c) Waveform 3 (CAN communication line)

Item

Content

Terminal

CH1: z16-25 (CA1H) - z16-27 (GND)

CH2: z16-26 (CA1L) - z16-27 (GND)

Equipment Setting

1 V/DIV., 50 μs/DIV.

Condition

Power switch on (IG)

HINT:

The waveform will vary depending on the content of the digital communication (digital signal).

(d) Waveform 4 (CAN communication line)

Item

Content

Terminal

CH1: z16-29 (CA2H) - z16-27 (GND)

CH2: z16-28 (CA2L) - z16-27 (GND)

Equipment Setting

1 V/DIV., 50 μs/DIV.

Condition

Power switch on (IG)

HINT: