Last Modified: 11-20-2023 |
6.11:8.1.0 |
Doc ID: RM1000000015DQN |
Model Year Start: 2018 |
Model: Camry HV |
Prod Date Range: [07/2017 - 09/2018] |
Title: HYBRID / BATTERY CONTROL: HYBRID BATTERY SYSTEM (for LITHIUM-ION BATTERY): P0A8111; Hybrid/EV Battery Cooling Fan 1 Circuit Short to Ground; 2018 MY Camry HV [07/2017 - 09/2018] |
DTC
|
P0A8111
|
Hybrid/EV Battery Cooling Fan 1 Circuit Short to Ground
|
DESCRIPTION
The battery cooling blower assembly speed is controlled by the battery ECU assembly. Power is supplied to the battery cooling blower assembly when the MREL terminal of the hybrid vehicle control ECU assembly turns on the IGCT relay. The battery ECU assembly sends command signals (SI0) to the battery cooling blower assembly to adjust the fan speed to an appropriate speed for the HV battery temperature. The frequency (FP0) of the battery cooling blower assembly is sent to the battery ECU assembly as a monitor signal.
DTC No.
|
Detection Item
|
DTC Detection Condition
|
Trouble Area
|
MIL
|
Warning Indicate
|
P0A8111
|
Hybrid/EV Battery Cooling Fan 1 Circuit Short to Ground
|
Both of the following conditions are met:
-
The speed calculated based on the battery cooling blower assembly output frequency is not within the target control speed range.
-
The battery cooling blower assembly speed is excessively low when a certain level of speed is requested (possibility of an open or short to ground in connected circuits, or motor locking).
(1 trip detection logic)
|
-
Battery cooling blower assembly
-
Battery ECU assembly
-
BATT FAN fuse
-
Wire harness or connector
|
Comes on / Does not come on
|
Master Warning Light:
Comes on
|
Related Data List
DTC No.
|
Data List
|
P0A8111
|
-
Hybrid Battery Cooling Fan 1 Drive Request
-
Hybrid Battery Cooling Fan 1 Drive Status
-
Hybrid Battery Cooling Fan 1 Frequency
|
The following items can be helpful when performing repairs:
Data List
-
Hybrid Battery Temperature 1 to 6
-
BATT Voltage
HINT:
"Hybrid Battery Cooling Fan 1 Frequency" is detected when the battery cooling blower assembly is operating and its value changes in proportion to the battery cooling blower assembly speed.
MONITOR DESCRIPTION
If the battery ECU assembly detects that the speed of the battery cooling blower assembly is lower than the target speed, it will illuminate the MIL and store a DTC.
MONITOR STRATEGY
Related DTCs
|
P0A84 (INF P0A8111): Hybrid/EV Battery Cooling Fan 1 Circuit Short to Ground
|
Required sensors/components
|
Battery cooling blower assembly
|
Frequency of operation
|
Continuous
|
Duration
|
TMC's intellectual property
|
MIL operation
|
1 driving cycle
|
Sequence of operation
|
None
|
TYPICAL ENABLING CONDITIONS
The monitor will run whenever the following DTCs are not stored
|
TMC's intellectual property
|
Other conditions belong to TMC's intellectual property
|
-
|
TYPICAL MALFUNCTION THRESHOLDS
TMC's intellectual property
|
-
|
COMPONENT OPERATING RANGE
Battery ECU assembly
|
DTC P0A84 (INF P0A8111) is not detected
|
CONFIRMATION DRIVING PATTERN
HINT:
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click here
-
Connect the Techstream to the DLC3.
-
Turn the power switch on (IG) and turn the Techstream on.
-
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
-
Turn the power switch off and wait for 2 minutes or more.
-
Turn the power switch on (IG) and turn the Techstream on.
-
Enter the following menus: Powertrain / HV Battery / Active Test / Control the Hybrid Battery Cooling Fan.[*1]
-
Select fan mode 1 and operate the battery cooling blower assembly and wait for 60 seconds or more.[*2]
-
Enter the following menus: Powertrain / HV Battery / Utility / All Readiness.
-
Check the DTC judgment result.
HINT:
-
If the judgment result shows NORMAL, the system is normal.
-
If the judgment result shows ABNORMAL, the system has a malfunction.
-
If the judgment result shows INCOMPLETE or N/A, perform the normal judgment procedure again.
WIRING DIAGRAM
CAUTION / NOTICE / HINT
NOTICE:
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click here
HINT:
As the battery cooling blower assembly speed is excessively low, there is a possibility of an open or short to ground in connected circuits, or motor locking.
PROCEDURE
1.
|
CHECK DTC OUTPUT (HV BATTERY, HYBRID CONTROL)
|
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Enter the following menus: Powertrain / HV Battery and Hybrid Control / Trouble Codes.
(d) Check for DTCs.
Powertrain > HV Battery > Trouble Codes
Powertrain > Hybrid Control > Trouble Codes
Result
|
Proceed to
|
P0A8111 only is output, or DTCs except the ones in the table below are also output.
|
A
|
DTCs of hybrid battery system in the table below are output.
|
B
|
DTCs of hybrid control system in the table below are output.
|
C
|
System
|
Relevant DTC
|
Hybrid battery system
|
P060A47
|
Hybrid/EV Battery Energy Control Module Monitoring Processor Watchdog / Safety MCU Failure
|
P060B49
|
Hybrid/EV Battery Energy Control Module A/D Processing Internal Electronic Failure
|
P060687
|
Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Missing Message
|
Hybrid control system
|
P0A1F94
|
Hybrid/EV Battery Energy Control Module Unexpected Operation
|
(e) Turn the power switch off.
A
|
|
|
2.
|
PERFORM ACTIVE TEST USING TECHSTREAM (CONTROL THE HYBRID BATTERY COOLING FAN)
|
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Enter the following menus: Powertrain / HV Battery / Trouble Codes.
(d) Clear the DTCs and freeze frame data.
Powertrain > HV Battery > Clear DTCs
(e) Enter the following menus: Powertrain / HV Battery / Active Test / Control the Hybrid Battery Cooling Fan.
Powertrain > HV Battery > Active Test
Tester Display
|
Measurement Item
|
Control Range
|
Restrict Condition
|
Control the Hybrid Battery Cooling Fan
|
Change the battery cooling blower assembly operation and blower volume.
|
0, 1, 2, 3, 4, 5, 6
|
Intake air temperature -10°C (14°F) or higher
|
Powertrain > HV Battery > Active Test
Tester Display
|
Control the Hybrid Battery Cooling Fan
|
(f) Select fan mode 6 in the "Control the Hybrid Battery Cooling Fan" Active Test to operate the battery cooling blower assembly.
NOTICE:
If the Active Test cannot be performed, skip it and proceed to the next step to check if the fan operates and air is sucked. In accordance with fail-safe system operation, the battery ECU assembly sends a command to operate the battery cooling blower assembly.
(g) Check that the battery cooling blower assembly operates, air is sucked into the inlet duct and the operation sound is normal.
HINT:
The battery cooling blower assembly may not stop even when turning the cooling fan off in the "Control the Hybrid Battery Cooling Fan" Active Test. This is due to HV system control and is not a malfunction.
OK:
The battery cooling blower assembly operates.
(h) Turn the power switch off.
OK
|
|
|
3.
|
CHECK HARNESS AND CONNECTOR (BATTERY ECU ASSEMBLY - BATTERY COOLING BLOWER ASSEMBLY)
|
CAUTION:
Be sure to wear insulated gloves and protective goggles.
(a) Check that the service plug grip is not installed.
NOTICE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
(b) Remove the No. 1 HV battery hose.
Click here
(c) Disconnect the z16 battery ECU assembly connector.
NOTICE:
Before disconnecting the connector, check that it is not loose or disconnected.
|
|
(d) Disconnect the R24 battery cooling blower assembly connector.
NOTICE:
Before disconnecting the connector, check that it is not loose or disconnected.
|
|
(e) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
R24-1 (FP0) - z16-15 (FP0)
|
Power switch off
|
Below 1 Ω
|
z16-15 (FP0) - Body ground and other terminals
|
Power switch off
|
10 kΩ or higher
|
|
|
*a
|
Front view of wire harness connector
(to Battery ECU Assembly)
|
*b
|
Front view of wire harness connector
(to Battery Cooling Blower Assembly)
|
|
|
(f) Connect the cable to the negative (-) auxiliary battery terminal.
(g) Turn the power switch on (IG).
(h) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
|
Condition
|
Specified Condition
|
z16-15 (FP0) - Body ground
|
Power switch on (IG)
|
Below 1 V
|
NOTICE:
-
Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
-
If the power switch is turned on (IG) with the connectors disconnected, other DTCs will be stored. Be sure to clear the DTCs after the inspection.
HINT:
As there might be an intermittent malfunction, inspect the following items even if the measured voltage is as specified.
Check the condition of each wire harness and each connector between the battery ECU assembly connector and battery cooling blower assembly.
(i) Turn the power switch off.
(j) Disconnect the cable from the negative (-) auxiliary battery terminal.
(k) Reconnect the R24 battery cooling blower assembly connector.
(l) Reconnect the z16 battery ECU assembly connector.
(m) Install the No. 1 HV battery hose.
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
OK
|
|
|
4.
|
READ VALUE USING TECHSTREAM (HYBRID BATTERY COOLING FAN 1 FREQUENCY)
|
CAUTION:
Be sure to wear insulated gloves and protective goggles.
(a) Check that the service plug grip is not installed.
NOTICE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
(b) Remove the No. 4 HV battery protector.
Click here
(c) Connect the cable to the negative (-) auxiliary battery terminal.
(d) Connect the Techstream to the DLC3.
(e) Turn the power switch on (IG).
(f) Enter the following menus: Powertrain / HV Battery / Trouble Codes.
(g) Clear the DTCs and freeze frame data.
Powertrain > HV Battery > Clear DTCs
(h) Enter the following menus: Powertrain / HV Battery / Active Test / Control the Hybrid Battery Cooling Fan.
Powertrain > HV Battery > Active Test
Tester Display
|
Measurement Item
|
Control Range
|
Restrict Condition
|
Control the Hybrid Battery Cooling Fan
|
Change the battery cooling blower assembly operation and blower volume.
|
0, 1, 2, 3, 4, 5, 6
|
Intake air temperature -10°C (14°F) or higher
|
Powertrain > HV Battery > Active Test
Tester Display
|
Control the Hybrid Battery Cooling Fan
|
(i) Enter the following menus: Powertrain / HV Battery / Data List / Hybrid Battery Cooling Fan 1 Frequency.
Powertrain > HV Battery > Data List
Tester Display
|
Hybrid Battery Cooling Fan 1 Frequency
|
(j) Select each fan mode (1 to 6) in the "Control the Hybrid Battery Cooling Fan" Active Test to operate the battery cooling blower assembly.
NOTICE:
If the Active Test cannot turn off the battery cooling blower assembly, skip it and proceed to the next step to check the frequency value. In accordance with fail-safe system operation, the battery ECU assembly sends a command to operate the battery cooling fan assembly.
(k) While the cooling fan is operating, compare the value in the Data List (Hybrid Battery Cooling Fan 1 Frequency) with the frequency value that was actually measured at the battery ECU assembly connector.
Specified Condition:
Tester Connection
|
Condition
|
R20-14 (FP0) - R20-4 (GND)
|
Battery cooling blower assembly operating (Active Test of cooling fan being performed)
|
NOTICE:
Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
HINT:
Compare the values in each fan mode (1 to 6). If the Active Test cannot be performed, compare the values only in the current fan mode.
|
|
*a
|
Component with harness connected
(Battery ECU Assembly)
|
|
|
Result
|
Proceed to
|
Both of the value in the Data List (Hybrid Battery Cooling Fan 1 Frequency) and the actual measured value at the battery ECU assembly connector are 0 Hz.
|
A
|
Other than above
|
B
|
(l) Turn the power switch off.
(m) Disconnect the cable from the negative (-) auxiliary battery terminal.
(n) Install the No. 4 HV battery protector.
A
|
|
|
5.
|
CHECK BATTERY ECU ASSEMBLY
|
CAUTION:
Be sure to wear insulated gloves.
(a) Check that the service plug grip is not installed.
NOTICE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
(b) Remove the rear seat cushion leg sub-assembly.
Click here
(c) Disconnect the R24 battery cooling bower assembly connector.
NOTICE:
Before disconnecting the connector, check that it is not loose or disconnected.
|
|
(d) Connect the cable to the negative (-) auxiliary battery terminal.
(e) Turn the power switch on (IG).
(f) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
|
Condition
|
Specified Condition
|
R24-1 (FP0) - R24-3 (GND0)
|
Power switch on (IG)
|
4.5 to 5.5 V
|
NOTICE:
-
Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
-
If the power switch is turned on (IG) with the connectors disconnected, other DTCs will be stored. Be sure to clear the DTCs after the inspection.
|
|
*a
|
Front view of wire harness connector
(to Battery Cooling Blower Assembly)
|
|
|
(g) Turn the power switch off.
(h) Disconnect the cable from the negative (-) auxiliary battery terminal.
(i) Reconnect the R24 battery cooling blower assembly connector.
(j) Install the rear seat cushion leg sub-assembly.
6.
|
CHECK BATTERY ECU ASSEMBLY (FREQUENCY)
|
CAUTION:
Be sure to wear insulated gloves and protective goggles.
(a) Check that the service plug grip is not installed.
NOTICE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
(b) Remove the No. 4 HV battery protector.
Click here
(c) Connect the cable to the negative (-) auxiliary battery terminal.
(d) Connect the Techstream to the DLC3.
(e) Turn the power switch on (IG).
(f) Enter the following menus: Powertrain / HV Battery / Trouble Codes.
(g) Clear the DTCs and freeze frame data.
Powertrain > HV Battery > Clear DTCs
(h) Enter the following menus: Powertrain / HV Battery / Active Test / Control the Hybrid Battery Cooling Fan.
Powertrain > HV Battery > Active Test
Tester Display
|
Measurement Item
|
Control Range
|
Restrict Condition
|
Control the Hybrid Battery Cooling Fan
|
Change the battery cooling blower assembly operation and blower volume.
|
0, 1, 2, 3, 4, 5, 6
|
Intake air temperature -10°C (14°F) or higher
|
Powertrain > HV Battery > Active Test
Tester Display
|
Control the Hybrid Battery Cooling Fan
|
(i) Enter the following menus: Powertrain / HV Battery / Data List / Hybrid Battery Cooling Fan 1 Frequency.
Powertrain > HV Battery > Data List
Tester Display
|
Hybrid Battery Cooling Fan 1 Frequency
|
(j) Select each fan mode (1 to 6) in the "Control the Hybrid Battery Cooling Fan" Active Test to operate the battery cooling blower assembly.
NOTICE:
If the Active Test cannot turn off the battery cooling blower assembly, skip it and proceed to the next step to check the frequency value. In accordance with fail-safe system operation, the battery ECU assembly sends a command to operate the battery cooling blower assembly.
(k) While the cooling fan is operating, compare the value in the Data List (Hybrid Battery Cooling Fan 1 Frequency) with the frequency value that was actually measured at the battery ECU assembly connector.
Specified Condition:
Tester Connection
|
Condition
|
Specified Condition
|
R20-14 (FP0) - R20-4 (GND)
|
Battery cooling blower assembly operating (Active Test of cooling fan being performed)
|
Difference between the value in the Data List (Hybrid Battery Cooling Fan 1 Frequency) and the actual measured value at the battery ECU assembly connector is 10% or less.
|
NOTICE:
Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
HINT:
Compare the values in each fan mode (1 to 6). If the Active Test cannot be performed, compare the values only in the current fan mode.
|
|
*a
|
Component with harness connected
(Battery ECU Assembly)
|
|
|
(l) Turn the power switch off.
(m) Disconnect the cable from the negative (-) auxiliary battery terminal.
(n) Install the No. 4 HV battery protector.
(a) Remove the BATT FAN fuse from the No. 4 relay block.
|
|
*1
|
No. 4 Relay Block
|
*2
|
BATT FAN Fuse
|
|
|
(b) Measure the resistance of the BATT FAN fuse.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
BATT FAN fuse
|
Power switch off
|
Below 1 Ω
|
(c) Install the BATT FAN fuse to the No. 4 relay block.
OK
|
|
|
8.
|
CHECK HARNESS AND CONNECTOR (IGCT RELAY - BATTERY COOLING BLOWER ASSEMBLY) (VOLTAGE)
|
CAUTION:
Be sure to wear insulated gloves.
(a) Check that the service plug grip is not installed.
NOTICE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
(b) Remove the rear seat cushion leg sub-assembly.
Click here
(c) Disconnect the R24 battery cooling bower assembly connector.
NOTICE:
Before disconnecting the connector, check that it is not loose or disconnected.
|
|
(d) Connect the cable to the negative (-) auxiliary battery terminal.
(e) Connect the Techstream to the DLC3.
(f) Turn the power switch on (IG).
(g) Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
(h) Clear the DTCs and freeze frame data.
Powertrain > Hybrid Control > Clear DTCs
(i) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
|
Condition
|
Specified Condition
|
R24-2 (IG0) - R24-3 (GND0)
|
Power switch on (IG)
|
11 to 14 V
|
NOTICE:
-
Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
-
If the power switch is turned on (IG) with the connectors disconnected, other DTCs will be stored. Be sure to clear the DTCs after the inspection.
HINT:
As there might be an intermittent malfunction, inspect the following items even if the measured voltage is as specified.
-
Installation condition of fuse(s) (before removing fuse(s)) (IG circuit)
-
Fuse condition (before and after removing fuse(s)) (IG circuit)
-
Connection condition of connectors (IG circuit)
-
Wire harness condition (IG circuit)
-
Wire harness condition (GND circuit)
|
|
*a
|
Front view of wire harness connector
(to Battery Cooling Blower Assembly)
|
|
|
(j) Turn the power switch off.
(k) Disconnect the cable from the negative (-) auxiliary battery terminal.
(l) Reconnect the R24 battery cooling blower assembly connector.
(m) Install the rear seat cushion leg sub-assembly.
OK
|
|
|
9.
|
CHECK HARNESS AND CONNECTOR (BATTERY ECU ASSEMBLY - BATTERY COOLING BLOWER ASSEMBLY)
|
CAUTION:
Be sure to wear insulated gloves and protective goggles.
(a) Check that the service plug grip is not installed.
NOTICE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
(b) Remove the No. 1 HV battery hose.
Click here
(c) Disconnect the z16 battery ECU assembly connector.
NOTICE:
-
Before disconnecting the connector, check that it is not loose or disconnected.
-
Check that each connector between the battery ECU assembly and battery cooling blower assembly is not loose or disconnected.
|
|
(d) Disconnect the R24 battery cooling blower assembly connector.
NOTICE:
-
Before disconnecting the connector, check that it is not loose or disconnected.
-
Check the terminals of the connector for deformation and corrosion.
|
|
(e) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
z16-14 (SI0) - R24-4 (SI0)
|
Power switch off
|
Below 1 Ω
|
R24-4 (SI0) - Body ground and other terminals
|
Power switch off
|
10 kΩ or higher
|
NOTICE:
Make sure that each connector between the battery ECU assembly and battery cooling blower assembly is not loose or disconnected and its terminals are not deformed or corroded.
|
|
*a
|
Front view of wire harness connector
(to Battery ECU Assembly)
|
*b
|
Front view of wire harness connector
(to Battery Cooling Blower Assembly)
|
|
|
(f) Connect the cable to the negative (-) auxiliary battery terminal.
(g) Turn the power switch on (IG).
(h) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
|
Condition
|
Specified Condition
|
R24-4 (SI0) - Body ground
|
Power switch on (IG)
|
Below 1 V
|
NOTICE:
-
Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
-
If the power switch is turned on (IG) with the connectors disconnected, other DTCs will be stored. Be sure to clear the DTCs after the inspection.
HINT:
As there might be an intermittent malfunction, inspect the following items even if the measured voltage is as specified.
Check the condition of each wire harness and each connector between the battery ECU assembly connector and battery cooling blower assembly.
(i) Turn the power switch off.
(j) Disconnect the cable from the negative (-) auxiliary battery terminal.
(k) Reconnect the R24 battery cooling blower assembly connector.
(l) Reconnect the z16 battery ECU assembly connector.
(m) Install the No. 1 HV battery protector.
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
OK
|
|
|
10.
|
CHECK BATTERY ECU ASSEMBLY
|
(a) Remove the battery ECU assembly.
Click here
(b) Measure the resistance according to the value(s) in the table below.
*a
|
Component without harness connected
(Battery ECU Assembly)
|
-
|
-
|
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
z16-14 (SI0) -z16-27 (GND)
|
Power switch off
|
10 kΩ or higher
|
(c) Install the battery ECU assembly.
OK
|
|
|
11.
|
CHECK BATTERY ECU ASSEMBLY (SI0 VOLTAGE)
|
CAUTION:
Be sure to wear insulated gloves and protective goggles.
(a) Check that the service plug grip is not installed.
NOTICE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
(b) Remove the No. 4 HV battery protector.
Click here
(c) Connect the cable to the negative (-) auxiliary battery terminal.
(d) Turn the power switch on (IG).
(e) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
|
Condition
|
Specified Condition
|
R20-12 (SI0) -R20-4 (GND)
|
Power switch on (IG)
|
4.5 to 5.5 V
|
NOTICE:
Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
|
|
*a
|
Component with harness connected
(Battery ECU Assembly)
|
|
|
(f) Turn the power switch off.
(g) Disconnect the cable from the negative (-) auxiliary battery terminal.
(h) Install the No. 4 HV battery protector.
OK
|
|
|
12.
|
CHECK BATTERY COOLING BLOWER ASSEMBLY
|
CAUTION:
Be sure to wear insulated gloves and protective goggles.
(a) Check that the service plug grip is not installed.
NOTICE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
(b) Remove the No. 4 HV battery protector.
Click here
(c) Connect the cable to the negative (-) auxiliary battery terminal.
(d) Connect the Techstream to the DLC3.
(e) Turn the power switch on (IG).
(f) Enter the following menus: Powertrain / HV Battery / Trouble Codes.
(g) Clear the DTCs and freeze frame data.
Powertrain > HV Battery > Clear DTCs
(h) Enter the following menus: Powertrain / HV Battery / Active Test / Control the Hybrid Battery Cooling Fan.
Powertrain > HV Battery > Active Test
Tester Display
|
Measurement Item
|
Control Range
|
Restrict Condition
|
Control the Hybrid Battery Cooling Fan
|
Change the battery cooling blower assembly operation and blower volume.
|
0, 1, 2, 3, 4, 5, 6
|
Intake air temperature -10°C (14°F) or higher
|
Powertrain > HV Battery > Active Test
Tester Display
|
Control the Hybrid Battery Cooling Fan
|
(i) Select each fan mode (1 to 6) in the "Control the Hybrid Battery Cooling Fan" Active Test to operate the battery cooling blower assembly.
NOTICE:
If the Active Test cannot turn off the battery cooling blower assembly, skip it and proceed to the next step to check the waveform. In accordance with fail-safe system operation, the battery ECU assembly sends a command to operate the battery cooling blower assembly.
(j) Connect an oscilloscope to the R20 battery ECU assembly connector and check the waveform.
Item
|
Content
|
Tester Connection
|
R20-12 (SI0) - R20-4 (GND)
|
Equipment Setting
|
10 V/DIV., 1 ms./DIV.
|
Condition
|
Battery cooling blower assembly operating (Active Test of cooling fan being performed)
|
NOTICE:
Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
HINT:
-
Perform this inspection with the battery ECU assembly connector connected.
-
The wave length will vary with the operating speed of the battery cooling blower assembly.
|
|
*a
|
Component with harness connected
(Battery ECU Assembly)
|
|
|
(k) Turn the power switch off.
(l) Disconnect the cable from the negative (-) auxiliary battery terminal.
(m) Install the No. 4 HV battery protector.
|
|
Result
|
Proceed to
|
Normal (The pulse output of waveform 1)
|
A
|
No pulse generation
|
B
|
13.
|
CHECK HARNESS AND CONNECTOR (BATTERY COOLING BLOWER ASSEMBLY - BODY GROUND)
|
CAUTION:
Be sure to wear insulated gloves.
(a) Check that the service plug grip is not installed.
NOTICE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
(b) Remove the rear seat cushion leg sub-assembly.
Click here
(c) Disconnect the R24 battery cooling bower assembly connector.
NOTICE:
Before disconnecting the connector, check that it is not loose or disconnected.
|
|
(d) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
R24-3 (GND0) - Body ground
|
Power switch off
|
Below 1 Ω
|
|
|
*a
|
Front view of wire harness connector
(to Battery Cooling Blower Assembly)
|
|
|
(e) Connect the R24 battery cooling bower assembly connector.
(f) Install the rear seat cushion leg sub-assembly.
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
OK
|
|
|
14.
|
CHECK HARNESS AND CONNECTOR (BATTERY ECU ASSEMBLY - BODY GROUND)
|
CAUTION:
Be sure to wear insulated gloves and protective goggles.
(a) Check that the service plug grip is not installed.
NOTICE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
(b) Remove the No. 1 HV battery hose.
Click here
(c) Disconnect the z16 battery ECU assembly connector.
NOTICE:
Before disconnecting the connector, check that it is not loose or disconnected.
|
|
(d) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
z16-27 (GND) - Body ground
|
Power switch off
|
Below 1 Ω
|
|
|
*a
|
Front view of wire harness connector
(to Battery ECU Assembly)
|
|
|
(e) Reconnect the z16 battery ECU assembly connector.
(f) Install the No. 1 HV battery hose.
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
OK
|
|
|
15.
|
CHECK HARNESS AND CONNECTOR (BATTERY ECU ASSEMBLY - BODY GROUND)
|
CAUTION:
Be sure to wear insulated gloves and protective goggles.
(a) Check that the service plug grip is not installed.
NOTICE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
(b) Remove the No. 1 HV battery hose.
Click here
(c) Disconnect the z16 battery ECU assembly connector.
NOTICE:
Before disconnecting the connector, check that it is not loose or disconnected.
|
|
(d) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
z16-3 (GND1) - Body ground
|
Power switch off
|
Below 1 Ω
|
|
|
*a
|
Front view of wire harness connector
(to Battery ECU Assembly)
|
|
|
(e) Reconnect the z16 battery ECU assembly connector.
(f) Install the No. 1 HV battery hose.
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
OK
|
|
|
16.
|
CHECK HARNESS AND CONNECTOR (IGCT RELAY - BATTERY COOLING BLOWER ASSEMBLY)
|
CAUTION:
Be sure to wear insulated gloves.
(a) Check that the service plug grip is not installed.
NOTICE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
(b) Remove the IGCT relay from the No. 6 relay block.
NOTICE:
Check the terminals of the relay for deformation and corrosion.
(c) Remove the rear seat cushion leg sub-assembly.
Click here
(d) Disconnect the R24 battery cooling blower assembly connector.
NOTICE:
-
Check that each connector between the IGCT relay and battery cooling blower assembly is not loose or disconnected.
-
Before disconnecting the connector, check that it is not loose or disconnected.
|
|
(e) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
IGCT relay holder 5 - R24-2 (IG0)
|
Power switch off
|
Below 1 Ω
|
NOTICE:
-
When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.
-
Check that each connector between the IGCT relay and battery cooling blower assembly is not loose or disconnected.
|
|
*1
|
No. 6 Relay Block
|
*a
|
Front view of wire harness connector
(to Battery Cooling Blower Assembly)
|
*b
|
IGCT Relay Holder
|
|
|
(f) Reconnect the R24 battery cooling blower assembly connector.
(g) Install the rear seat cushion leg sub-assembly.
(h) Install the IGCT relay to the No. 6 relay block.
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
17.
|
CHECK HARNESS AND CONNECTOR (BATT FAN FUSE - BATTERY COOLING BLOWER ASSEMBLY)
|
CAUTION:
Be sure to wear insulated gloves.
(a) Check that the service plug grip is not installed.
NOTICE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
(b) Remove the BATT FAN fuse from the No. 4 relay block.
(c) Remove the rear seat cushion leg sub-assembly.
Click here
(d) Disconnect the R24 battery cooling blower assembly connector.
NOTICE:
Before disconnecting the connector, check that it is not loose or disconnected.
|
|
(e) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
R24-2 (IG0) - Terminals other than 2 (BATT FAN fuse) and body ground
|
Power switch off
|
10 kΩ or higher
|
NOTICE:
When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.
|
|
*1
|
No. 4 Relay Block
|
*a
|
Front view of wire harness connector
(to Battery Cooling Blower Assembly)
|
*b
|
BATT FAN Fuse Holder
|
|
|
(f) Reconnect the R24 battery cooling blower assembly connector.
(g) Install the rear seat cushion leg sub-assembly.
(h) Install the BATT FAN fuse to the No. 4 relay block.
OK
|
|
|
18.
|
CHECK BATTERY COOLING BLOWER ASSEMBLY
|
CAUTION:
Be sure to wear insulated gloves.
(a) Check that the service plug grip is not installed.
NOTICE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
(b) Remove the rear seat cushion leg sub-assembly.
Click here
(c) Disconnect the R24 battery cooling blower assembly connector.
NOTICE:
Before disconnecting the connector, check that it is not loose or disconnected.
|
|
(d) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
R24-2 (IG0) - R24-3 (GND0) and Body ground
|
Power switch off
|
10 kΩ or higher
|
NOTICE:
When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.
|
|
*a
|
Component without harness connected
(Battery Cooling Blower Assembly)
|
|
|
(e) Reconnect the R24 battery cooling blower assembly connector.
(f) Install the rear seat cushion leg sub-assembly.
OK |
|
REPLACE FUSE (BATT FAN)
|
NG
|
|
|
19.
|
REPLACE BATTERY COOLING BLOWER ASSEMBLY
|
Click here
NEXT |
|
REPLACE FUSE (BATT FAN)
|
20.
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
NEXT |
|
REPLACE FUSE (BATT FAN)
|
|