Last Modified: 11-20-2023 |
6.11:8.1.0 |
Doc ID: RM10000000157CA |
Model Year Start: 2018 |
Model: Camry HV |
Prod Date Range: [07/2017 -
] |
Title: LIGHTING (EXT): LIGHTING SYSTEM (w/ AFS): Taillight Relay Circuit; 2018 - 2024 MY Camry HV [07/2017 - ] |
DESCRIPTION
The main body ECU (multiplex network body ECU) controls the operation of the TAIL relay.
WIRING DIAGRAM
CAUTION / NOTICE / HINT
PROCEDURE
1.
|
PERFORM ACTIVE TEST USING TECHSTREAM
|
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Main Body / Active Test.
(e) Perform the Active Test according to the display on the Techstream.
Body Electrical > Main Body > Active Test
Tester Display
|
Measurement Item
|
Control Range
|
Diagnostic Note
|
Taillight Relay
|
Taillight relay
|
OFF or ON
|
-
|
Body Electrical > Main Body > Active Test
Tester Display
|
Taillight Relay
|
OK:
Taillights illuminate.
NG
|
|
|
2.
|
CHECK HARNESS AND CONNECTOR (POWER SOURCE - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
|
(a) Disconnect the 3F instrument panel junction block assembly connector.
(b) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
|
Condition
|
Specified Condition
|
3F-1 - Body ground
|
Power switch off
|
11 to 14 V
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
OK
|
|
|
3.
|
INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
|
*a
|
Component without harness connected
(Instrument Panel Junction Block Assembly)
|
-
|
-
|
(a) Remove the instrument panel junction block assembly.
Click here
(b) Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.
(c) Connect a positive (+) lead from the auxiliary battery to terminal 3F-1.
(d) Connect a negative (-) lead from the auxiliary battery to terminal MB-14 (TRLY).
(e) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
|
Condition
|
Specified Condition
|
3D-30 - Auxiliary battery negative (-) terminal
|
Always
|
11 to 14 V
|
|