Last Modified: 11-20-2023 |
6.11:8.1.0 |
Doc ID: RM100000001579G |
Model Year Start: 2018 |
Model: Camry HV |
Prod Date Range: [07/2017 -
] |
Title: THEFT DETERRENT / KEYLESS ENTRY: SMART KEY SYSTEM (for Start Function): Power Source Mode does not Change to ON (ACC); 2018 - 2024 MY Camry HV [07/2017 - ] |
Power Source Mode does not Change to ON (ACC)
|
DESCRIPTION
If the power switch is pressed with the electrical key transmitter sub-assembly in the cabin, the certification ECU (smart key ECU assembly) receives a signal and changes the power source mode.
Related Data List and Active Test Items
Problem Symptom
|
Data List and Active Test
|
Power source mode does not change to on (ACC) but does change to on (IG)
|
Power Source Control
-
Power Supply Condition
-
ACC Relay Monitor
|
WIRING DIAGRAM
CAUTION / NOTICE / HINT
PROCEDURE
(a) Using the Techstream, check for certification ECU (smart key ECU assembly) DTCs.
Body Electrical > Power Source Control > Trouble Codes
Body Electrical > Smart Key > Trouble Codes
Result
|
Proceed to
|
DTCs are not output
|
A
|
Smart key system (for Start Function) DTCs are output
|
B
|
A
|
|
|
2.
|
CHECK CERTIFICATION ECU (SMART KEY ECU ASSEMBLY)
|
(a) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
|
Condition
|
Specified Condition
|
K62-16 (ACCD) - Body ground
|
Power switch on (ACC) → Power switch on (IG)
|
1 V or less → 9 V or higher
|
|
|
*a
|
Component with harness connected
(Certification ECU (Smart Key ECU Assembly))
|
|
|
OK
|
|
|
3.
|
CHECK HARNESS AND CONNECTOR (CERTIFICATION ECU (SMART KEY ECU ASSEMBLY) - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY AND BODY GROUND)
|
(a) Disconnect the K62 certification ECU (smart key ECU assembly) connector.
(b) Disconnect the 3A, 3B and 3F instrument panel junction block assembly connectors.
(c) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
K62-16 (ACCD) - 3A-30
|
Always
|
Below 1 Ω
|
3B-3 - Body ground
|
Always
|
Below 1 Ω
|
K62-16 (ACCD) or 3A-30 - Other terminals and body ground
|
Always
|
10 kΩ or higher
|
(d) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
|
Condition
|
Specified Condition
|
3F-1 - Body ground
|
Power switch off
|
11 to 14 V
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
OK
|
|
|
4.
|
CHECK INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY (ACC RELAY)
|
(a) Remove the instrument panel junction block assembly.
Click here
(b) Connect all of the instrument panel junction block assembly connectors.
(c) Measure the voltage according to the value(s) in the table below.
*a
|
Component without harness connected
(Instrument Panel Junction Block Assembly)
|
-
|
-
|
Standard Voltage:
Tester Connection
|
Condition
|
Specified Condition
|
3D-26 - Body ground
|
Power switch on (IG)
|
11 to 14 V
|
|