Last Modified: 11-20-2023 6.11:8.1.0 Doc ID: RM10000000156C8
Model Year Start: 2018 Model: Camry HV Prod Date Range: [07/2017 - 10/2020]
Title: A25A-FXS (COOLING): FLOW SHUTTING VALVE: REMOVAL; 2018 - 2020 MY Camry HV [07/2017 - 10/2020]

REMOVAL

CAUTION / NOTICE / HINT

The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed and installed, or replaced during flow shutting valve (water by-pass hose assembly) removal/installation are shown below.

Necessary Procedures After Parts Removed/Installed/Replaced

Replaced Part or Performed Procedure

Necessary Procedures

Effect/Inoperative Function when Necessary Procedure not Performed

Link

*1: When performing learning using the Techstream.

Click here 2018 - 2020 MY Camry HV [07/2017 - 10/2020]; PARK ASSIST / MONITORING: INTELLIGENT CLEARANCE SONAR SYSTEM: CALIBRATION

Auxiliary battery terminal is disconnected/reconnected

Perform steering sensor zero point calibration

Lane departure alert system (w/ Steering Control)

2018 - 2020 MY Camry HV [07/2017 - 10/2020]; PRE-COLLISION: PRE-COLLISION SYSTEM: INITIALIZATION

Pre-collision system

Intelligent clearance sonar system*

Lighting system (w/ AFS)(EXT)

Memorize steering angle neutral point

Parking assist monitor system

2018 - 2024 MY Camry HV [07/2017 -        ]; PARK ASSIST / MONITORING: PARKING ASSIST MONITOR SYSTEM: INITIALIZATION

Panoramic view monitor system

2018 - 2020 MY Camry HV [07/2017 - 10/2020]; PARK ASSIST / MONITORING: PANORAMIC VIEW MONITOR SYSTEM: INITIALIZATION

Replacement of inverter with converter assembly

Resolver learning

  • DTCs are stored
  • Slight vibration at a vehicle speed of 5 km/h (3 mph) or less
  • Shock or vibration during acceleration

2018 - 2024 MY Camry HV [07/2017 -        ]; HYBRID / BATTERY CONTROL: MOTOR GENERATOR CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY): UTILITY for Nickel Metal Hydride Battery

2018 - 2024 MY Camry HV [07/2017 -        ]; HYBRID / BATTERY CONTROL: MOTOR GENERATOR CONTROL SYSTEM (for LITHIUM-ION BATTERY): UTILITY for Lithium-ion Battery

Replacement of ECM

Perform Vehicle Identification Number (VIN) registration

MIL comes on

2018 - 2024 MY Camry HV [07/2017 -        ]; A25A-FXS (ENGINE CONTROL): SFI SYSTEM: REGISTRATION

NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click here 2018 - 2019 MY Camry HV [07/2017 - 09/2019]; INTRODUCTION: REPAIR INSTRUCTION: PRECAUTION 2020 - 2024 MY Camry HV [09/2019 -        ]; INTRODUCTION: REPAIR INSTRUCTION: PRECAUTION

PROCEDURE

1. REMOVE INVERTER WITH CONVERTER ASSEMBLY

Click here 2018 - 2020 MY Camry HV [07/2017 - 10/2020]; HYBRID / BATTERY CONTROL: INVERTER WITH CONVERTER: REMOVAL

2. DRAIN ENGINE COOLANT (for Engine)

Click here 2018 - 2024 MY Camry HV [07/2017 -        ]; MAINTENANCE: COOLANT (for Engine): REPLACEMENT+

3. REMOVE FLOW SHUTTING VALVE (WATER BY-PASS HOSE ASSEMBLY)

(a) Disconnect the flow shutting valve (water by-pass hose assembly) connector.

(b) Disconnect the outlet heater hose connector from the No. 2 water by-pass pipe sub-assembly.

NOTICE:

Remove any foreign matter on the No. 2 water by-pass pipe sub-assembly and outlet heater hose connector before performing this work.

(1) Pull out the retainer to disengage the lock claws and pull off the outlet heater hose connector.

*a

Retainer

Pull out

Pull off

(2) Check that there is no foreign matter on the sealing surfaces of the disconnected water lines. Clean them if necessary.

(3) Cover the disconnected No. 2 water by-pass pipe sub-assembly and outlet heater hose connector with plastic bags to prevent damage and contamination.

(c) Disconnect the inlet heater hose connector from the flow shutting valve (water by-pass hose assembly).

NOTICE:

Remove any foreign matter on the flow shutting valve (water by-pass hose assembly) and inlet heater hose connector before performing this work.

(1) Pull out the retainer to disengage the lock claws and pull off the inlet heater hose connector.

*a

Retainer

Pull out

Pull off

(2) Check that there is no foreign matter on the sealing surfaces of the disconnected water lines. Clean them if necessary.

(3) Cover the disconnected inlet heater hose connector with plastic bag to prevent damage and contamination.

(d) Remove the bolt to disconnect the No. 2 water by-pass pipe sub-assembly.

(e) Remove the bolt to disconnect the flow shutting valve (water by-pass hose assembly).

(f) Slide the clip and disconnect the flow shutting valve (water by-pass hose assembly) from the water by-pass outlet sub-assembly.

HINT:

Use a container to catch any engine coolant which flows out of the flow shutting valve (water by-pass hose assembly) and water by-pass outlet sub-assembly.