Last Modified: 11-20-2023 6.11:8.1.0 Doc ID: RM1000000014XM9
Model Year Start: 2018 Model: Camry HV Prod Date Range: [07/2017 -           ]
Title: HYBRID / BATTERY CONTROL: WATER PUMP WITH MOTOR: REMOVAL; 2018 - 2024 MY Camry HV [07/2017 -        ]

REMOVAL

PROCEDURE

1. REMOVE FRONT WHEEL OPENING EXTENSION PAD LH

Click here 2018 MY Camry HV [07/2017 - 09/2018]; A25A-FXS (ENGINE MECHANICAL): ENGINE ASSEMBLY: REMOVAL+ 2019 - 2020 MY Camry HV [09/2018 - 10/2020]; A25A-FXS (ENGINE MECHANICAL): ENGINE ASSEMBLY: REMOVAL+ 2021 - 2024 MY Camry HV [10/2020 -        ]; A25A-FXS (ENGINE MECHANICAL): ENGINE ASSEMBLY: REMOVAL+

2. REMOVE FRONT WHEEL OPENING EXTENSION PAD RH

Click here 2018 MY Camry HV [07/2017 - 09/2018]; A25A-FXS (ENGINE MECHANICAL): ENGINE ASSEMBLY: REMOVAL+ 2019 - 2020 MY Camry HV [09/2018 - 10/2020]; A25A-FXS (ENGINE MECHANICAL): ENGINE ASSEMBLY: REMOVAL+ 2021 - 2024 MY Camry HV [10/2020 -        ]; A25A-FXS (ENGINE MECHANICAL): ENGINE ASSEMBLY: REMOVAL+

3. REMOVE NO. 1 ENGINE UNDER COVER

Click here 2018 MY Camry HV [07/2017 - 09/2018]; A25A-FXS (ENGINE MECHANICAL): ENGINE ASSEMBLY: REMOVAL+ 2019 - 2020 MY Camry HV [09/2018 - 10/2020]; A25A-FXS (ENGINE MECHANICAL): ENGINE ASSEMBLY: REMOVAL+ 2021 - 2024 MY Camry HV [10/2020 -        ]; A25A-FXS (ENGINE MECHANICAL): ENGINE ASSEMBLY: REMOVAL+

4. DRAIN COOLANT (for Inverter)

Click here 2018 - 2024 MY Camry HV [07/2017 -        ]; HYBRID / BATTERY CONTROL: COOLANT(for Inverter): REPLACEMENT+

5. REMOVE INVERTER WATER PUMP ASSEMBLY

(a) Disconnect the inverter water pump assembly connector.

To prevent coolant from entering the inverter water pump assembly connector, perform the following procedure.

NOTICE:

Apply insulating tape to the connectors of the wire harness and inverter water pump assembly.

(b) Remove the 2 bolts to remove the inverter water pump assembly from the fan shroud assembly.

(c) Slide the 2 clips and disconnect the No. 2 inverter cooling hose and No. 3 inverter cooling hose to remove the inverter water pump assembly.

NOTICE:

  • Put pieces of cloth into the pipes and disconnected hoses or cover the pipes and hoses with plastic bags to prevent foreign matter from entering the inverter water pump assembly and inverter cooling system.
  • Do not apply excessive force to the hoses.

*1

No. 2 Inverter Cooling Hose

*2

No. 3 Inverter Cooling Hose