                        | Last Modified: 02-14-2025 | 6.11:8.1.0 | Doc ID: RM1000000014XM1 |  
                        | Model Year Start: 2018 | Model: Camry HV | Prod Date Range: [07/2017 -                    
                                       ] |  
                        | Title: HYBRID / BATTERY CONTROL: HV BATTERY (for LITHIUM-ION BATTERY): RECOVERY INSPECTION; 2018 - 2024 MY Camry HV [07/2017 -        ] |  CAUTION / NOTICE / HINTHINT: In order to return the HV battery in a safe manner, it may be necessary to discharge it. The following pre-return inspection procedure can be used to determine whether or not it is necessary to discharge the HV battery the method that may be required. PROCEDURE
                     
                        
                           | 1.  | INSPECT FOR ELECTROLYTE LEAK |  CAUTION: Be sure to wear insulated gloves and protective goggles. 
                     
                        
                           | (a) Position the HV battery as shown in the illustration and leave it for 5 minutes. | 
                                 
                                    |   |  
                                    | 
                                          
                                             
                                             
                                          
                                          
                                             
                                                | *a | 155 mm (6.10 in.) or more |  |  |  (b) Check that no electrolyte is leaking from the HV battery. OK:  There is no electrolyte leaking from the HV battery. 
                     CAUTION: 
                        
Perform this procedure in an area where the battery will not be exposed to fire.
Do not touch the HV battery, unless absolutely necessary, as electrolyte may be leaking.
 NOTICE: If there is an electrolyte leak, make sure to wear insulated gloves and goggles and clean it using a piece of cloth. Do not leave electrolyte-contaminated cloths unattended. Dispose of them according to law or local regulations. 
                     
                        
                           | NG |   | DISCHARGING (WHEN USING THE SALT WATER SOLUTION) |  
                     
                        | 
                              
                                 | OK |  
                                 |   |  |  (a) Check the previously recorded DTCs which resulted in replacement of the HV battery. 
                     
                        
                           | Result | Proceed to |  
                           | DTC record not available. | A |  
                           | The HV battery was replaced due to a reason other than the DTCs listed in the following table. | B |  
                           | The HV battery was replaced due to one of the DTCs listed in the following table. | C |  
                     
                        
                     
                     
                        
                           | DTC No. |  
                           | P1A6017 |  
                           | P31AA17 |  
                           | P0C3000 |  
                           | P31B300 |  
                           | P1C7D49 |  
                     
                        | 
                              
                                 | A |  
                                 |   |  |  
                     
                        
                           | 3.  | CHECK HV BATTERY VOLTAGE |  CAUTION: Be sure to wear insulated gloves. (a) Measure the voltage according to the value(s) in the table below.   
                     
                        
                        
                        
                        
                     
                     
                        
                           | *A | Type A | *B | Type B |  
                           | *a | No. 1 HV Battery Main Cable (A) | *b | No. 2 HV Battery Main Cable (B) |  Standard Voltage:  
                     
                        
                        
                        
                     
                     
                        
                           | Tester Connection | Condition | Specified Condition |  
                           | A - B | Always | Below 292.3 V |  CAUTION: Make sure not to cross the probes of the electrical tester. 
                     
                        | 
                              
                                 | OK |  
                                 |   |  |  
                     
                        
                           | 4.  | INSULATION INSPECTION OF HV BATTERY |  CAUTION: Be sure to wear insulated gloves. (a) Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below. NOTICE: Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.   
                     
                        
                        
                        
                        
                     
                     
                        
                           | *A | Type A | *B | Type B |  
                           | *a | No. 1 HV Battery Main Cable (A) | *b | No. 2 HV Battery Main Cable (B) |  
                           | *c | Battery Outer Case | - | - |  Standard Resistance:  
                     
                        
                        
                        
                     
                     
                        
                           | Tester Connection | Condition | Specified Condition |  
                           | A - Battery Outer Case | Always | 1 MΩ or higher |  
                           | B - Battery Outer Case | Always | 1 MΩ or higher |  
                     
                        | 
                              
                                 | OK |  
                                 |   |  |  
                     
                        
                           | 5.  | HV BATTERY VISUAL CHECK |  CAUTION: Be sure to wear insulated gloves. (a) Check that the HV battery is not deformed or damaged. OK:  The HV battery is not deformed or damaged. 
                     
                        
                           | OK |   | RETURN HV BATTERY |  
                     
                        
                           | 6.  | HV BATTERY CONNECTORS VISUAL CHECK |  CAUTION: Be sure to wear insulated gloves and protective goggles. (a) Check that the orange connectors connected to the battery ECU assembly are not deformed or damaged. OK:  The connectors are not deformed or damaged. HINT: If any of the connectors are damaged, a Li-ion battery discharger will not be able to be connected to the HV battery. Soak the HV battery in a saltwater solution to discharge it. 
                     
                        
                           | OK |   | DISCHARGING (WHEN USING THE LI-ION BATTERY DISCHARGER) |  
                     
                        
                           | NG |   | DISCHARGING (WHEN USING THE SALT WATER SOLUTION) |  |