Last Modified: 11-20-2023 |
6.11:8.1.0 |
Doc ID: RM1000000014XFI |
Model Year Start: 2018 |
Model: Camry HV |
Prod Date Range: [07/2017 - 09/2018] |
Title: HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM: PTC Heater Circuit; 2018 MY Camry HV [07/2017 - 09/2018] |
DESCRIPTION
The air conditioning amplifier assembly sends operation signals to the PTC heater relays when quick heater assembly operation conditions are met. Based on the signals from the air conditioning amplifier assembly, the PTC heater relays turn on, and power is supplied to the quick heater assembly installed in the air conditioning radiator assembly.
Symptom
|
Factor
|
Heating performance is poor when it is cold.
|
-
Quick heater assembly malfunction
-
Air conditioning amplifier assembly malfunction
-
PTC heater relay malfunction
-
Harness or connector
|
WIRING DIAGRAM
CAUTION / NOTICE / HINT
NOTICE:
Inspect the fuses for circuits related to this system before performing the following procedure.
PROCEDURE
1.
|
INSPECT PTC HEATER RELAY
|
(a) Inspect the PTC heater relays.
Click here
NG |
|
REPLACE PTC HEATER RELAY
|
OK
|
|
|
2.
|
CHECK HARNESS AND CONNECTOR (POWER SOURCE - PTC HEATER RELAY)
|
(a) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
PTC HTR NO. 1
Tester Connection
|
Condition
|
Specified Condition
|
3 (PTC HTR NO. 1 relay) - Body ground
|
Power switch off
|
11 to 14 V
|
2 (PTC HTR NO. 1 relay) - Body ground
|
Power switch off
|
Below 1 V
|
2 (PTC HTR NO. 1 relay) - Body ground
|
Power switch on (IG)
|
11 to 14 V
|
Standard Voltage:
PTC HTR NO. 2
Tester Connection
|
Condition
|
Specified Condition
|
3 (PTC HTR NO. 2 relay) - Body ground
|
Power switch off
|
11 to 14 V
|
2 (PTC HTR NO. 2 relay) - Body ground
|
Power switch off
|
Below 1 V
|
2 (PTC HTR NO. 2 relay) - Body ground
|
Power switch on (IG)
|
11 to 14 V
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
OK
|
|
|
3.
|
CHECK HARNESS AND CONNECTOR (PTC HEATER RELAY - AIR CONDITIONING AMPLIFIER ASSEMBLY)
|
(a) Disconnect the K54 and K55 air conditioning amplifier assembly connectors.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
PTC HTR NO. 1
Tester Connection
|
Condition
|
Specified Condition
|
1 (PTC HTR NO. 1 relay) - K54-18 (PTC1)
|
Always
|
Below 1 Ω
|
1 (PTC HTR NO. 1 relay) or K54-18 (PTC1) - Body ground
|
Always
|
10 kΩ or higher
|
Standard Resistance:
PTC HTR NO. 2
Tester Connection
|
Condition
|
Specified Condition
|
1 (PTC HTR NO. 2 relay) - K55-10 (PTC2)
|
Always
|
Below 1 Ω
|
1 (PTC HTR NO. 2 relay) or K55-10 (PTC2) - Body ground
|
Always
|
10 kΩ or higher
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
OK
|
|
|
4.
|
CHECK HARNESS AND CONNECTOR (PTC HEATER RELAY - QUICK HEATER ASSEMBLY AND BODY GROUND)
|
(a) Disconnect the L1 and L2 quick heater assembly connectors.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
PTC HTR NO. 1
Tester Connection
|
Condition
|
Specified Condition
|
5 (PTC HTR NO. 1 relay) - L1-2 (B)
|
Always
|
Below 1 Ω
|
5 (PTC HTR NO. 1 relay) - L2-1 (B)
|
Always
|
Below 1 Ω
|
5 (PTC HTR NO. 1 relay) or L1-2 (B) - Other terminals and body ground
|
Always
|
10 kΩ or higher
|
5 (PTC HTR NO. 1 relay) or L2-1 (B) - Other terminals and body ground
|
Always
|
10 kΩ or higher
|
Standard Resistance:
PTC HTR NO. 2
Tester Connection
|
Condition
|
Specified Condition
|
5 (PTC HTR NO. 2 relay) - L2-3 (B)
|
Always
|
Below 1 Ω
|
5 (PTC HTR NO. 2 relay) or L2-3 (B) - Other terminals and body ground
|
Always
|
10 kΩ or higher
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
OK
|
|
|
5.
|
INSPECT QUICK HEATER ASSEMBLY
|
(a) Remove the quick heater assembly.
Click here
(b) Inspect the quick heater assembly.
Click here
|