Last Modified: 11-20-2023 6.11:8.1.0 Doc ID: RM1000000014UNT
Model Year Start: 2018 Model: Camry HV Prod Date Range: [07/2017 -           ]
Title: HYBRID / BATTERY CONTROL: MOTOR GENERATOR CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY): UTILITY; 2018 - 2024 MY Camry HV [07/2017 -        ]

UTILITY

ALL READINESS

HINT:

  • With "All Readiness", you can check whether or not the DTC judgment has been completed by using the Techstream.
  • Check "All Readiness" after simulating malfunction symptoms or for validation after finishing repairs.

(a) Connect the Techstream to the DLC3.

(b) Turn the power switch on (IG).

(c) Turn the Techstream on.

(d) Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

Powertrain > Motor Generator > Clear DTCs

(e) Turn the power switch off and wait for at least 2 minutes.

(f) Turn the power switch on (IG).

(g) Turn the Techstream on.

(h) Perform the DTC confirmation driving pattern to run the DTC judgment.

(i) Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.

Powertrain > Motor Generator > Utility

Tester Display

All Readiness

(j) Input the DTCs to be confirmed.

(k) Check the DTC judgment result.

Techstream Display

Description

NORMAL

  • DTC judgment completed
  • System normal

ABNORMAL

  • DTC judgment completed
  • System abnormal

INCOMPLETE

  • DTC judgment not completed
  • Perform the driving pattern

N/A

  • Unable to perform DTC judgment
  • Number of DTCs which do not fulfill DTC preconditions has reached ECU memory limit

If the judgment result shows INCOMPLETE or N/A, perform the DTC confirmation driving pattern again.

(l) Turn the power switch off.

CHECK FOR DIAGNOSIS RELATED INFORMATION

(a) Connect the Techstream to the DLC3.

(b) Turn the power switch on (IG).

(c) Turn the Techstream on.

(d) Enter the following menus: Powertrain / Motor Generator / Utility / Diagnosis Related Information.

Powertrain > Motor Generator > Utility

Tester Display

Diagnosis Related Information

(e) Check the diagnosis related information and freeze frame data, and then write them down.

CLEAR DIAGNOSIS RELATED INFORMATION

(a) Connect the Techstream to the DLC3.

(b) Turn the power switch on (IG).

(c) Turn the Techstream on.

(d) Enter the following menus: Powertrain / Motor Generator / Trouble Codes.

(e) Clear the diagnosis related information and freeze frame data.

Powertrain > Motor Generator > Clear DTCs

RESOLVER INITIALIZATION

NOTICE:

  • The resolver learned values cannot be initialized by disconnecting the cable from the negative (-) auxiliary battery terminal or removing a fuse.
  • If resolver learning is not performed after the inverter with converter assembly or a part related to the hybrid transaxle assembly has been replaced, the following DTCs may be stored and the symptoms may occur:
    • DTC output
      • P0BFF1D (Drive Motor "A" Circuit Current Out of Range)
      • P0C1900 (Drive Motor "A" Execution Torque Performance)
      • P0C7917 (Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold)
      • P0D3319 (DC/DC Converter Circuit Current Above Threshold)
      • P0E7100 (Generator Execution Torque Performance)
      • P1C5D19 (Drive Motor "A" Inverter Circuit Current Above Threshold)
      • P1C5F19 (Generator Inverter Circuit Current Above Threshold)
      • P1CA51D (Hybrid Generator Circuit Current Out of Range)
    • Slight vibration at a vehicle speed of 5 km/h (3 mph) or less
    • Shock or vibration during acceleration

Perform resolver initialization and/or learning according to the following table:

Part Replaced or Procedure Performed

Learning

Initialization

Inverter with converter assembly

-

Hybrid vehicle transaxle assembly

○*1

  • ○: Necessary
  • -: Not necessary

*1: If it is necessary to replace the hybrid vehicle transaxle assembly, make sure to perform resolver initialization before starting work.

HINT:

After performing resolver initialization, "Learning not completed" will be displayed on the multi-information display when the power switch is turned on (READY).

Related Data List

Data List

Detail

Generator Resolver Offset Value

Displays the resolver learning value.

Displays 0 after the inverter with converter assembly has been replaced (and learning has not been performed) or resolver initialization has been performed.

Displays the resolver installation offset amount after resolver learning is performed.

Generator Resolver Offset Complete Status

Displays the completion status of the resolver learning.

Displays ON when resolver learning is complete.

Motor Resolver Offset Value

Displays the resolver learning value.

Displays 0 after the inverter with converter assembly has been replaced (and learning has not been performed) or resolver initialization has been performed.

Displays the resolver installation offset amount after resolver learning is performed.

Motor Resolver Offset Complete Status

Displays the completion status of the resolver learning.

Displays ON when resolver learning is complete.

  • Related Data List Item:
    • Ready ON Status
    • Vehicle Speed
    • Shift Position
    • Accelerator Position
    • Motor Revolution
    • Generator Revolution
    • Motor Temperature
    • Generator Temperature
    • Inverter Coolant Temperature
    • Ambient Temperature
    • Atmospheric Pressure

(a) Initialize the learned value.

(1) Turn the power switch off and wait for 2 minute or more.

(2) Connect the Techstream to the DLC3.

(3) Turn the power switch on (IG).

(4) Turn the Techstream on.

(5) Enter the following menus: Powertrain / Motor Generator / Utility / Resolver Learning/Initialization.

Powertrain > Motor Generator > Utility

Tester Display

Resolver Learning/Initialization

(6) According to the display on the Techstream, select "Initialization" to perform resolver initialization.

NOTICE:

Do not turn the power switch on (READY) while performing resolver initialization. If the power switch is turned on (READY) and the engine starts, generator resolver learning will be performed and resolver initialization will be canceled.

(7) Check that the generator resolver learning incomplete message is displayed on the multi-information display.

(8) Turn the power switch off and wait for 1 minute or more.

(9) Turn the power switch on (IG).

RESOLVER LEARNING

NOTICE:

  • The resolver learned values cannot be initialized by disconnecting the cable from the negative (-) auxiliary battery terminal or removing a fuse.
  • If resolver learning is not performed after the inverter with converter assembly or a part related to the hybrid transaxle assembly has been replaced, the following DTCs may be stored and the symptoms may occur:
    • DTC output
      • P0BFF1D (Drive Motor "A" Circuit Current Out of Range)
      • P0C1900 (Drive Motor "A" Execution Torque Performance)
      • P0C7917 (Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold)
      • P0D3319 (DC/DC Converter Circuit Current Above Threshold)
      • P0E7100 (Generator Execution Torque Performance)
      • P1C5D19 (Drive Motor "A" Inverter Circuit Current Above Threshold)
      • P1C5F19 (Generator Inverter Circuit Current Above Threshold)
      • P1CA51D (Hybrid Generator Circuit Current Out of Range)
    • Slight vibration at a vehicle speed of 5 km/h (3 mph) or less
    • Shock or vibration during acceleration

Perform resolver initialization and/or learning according to the following table:

Part Replaced or Procedure Performed

Learning

Initialization

Inverter with converter assembly

-

Hybrid vehicle transaxle assembly

○*1

  • ○: Necessary
  • -: Not necessary

*1: If it is necessary to replace the hybrid vehicle transaxle assembly, make sure to perform resolver initialization before starting work.

HINT:

After performing resolver initialization, "Learning not completed" will be displayed on the multi-information display when the power switch is turned on (READY).

Related Data List

Data List

Detail

Generator Resolver Offset Value

Displays the resolver learning value.

Displays 0 after the inverter with converter assembly has been replaced (and learning has not been performed) or resolver initialization has been performed.

Displays the resolver installation offset amount after resolver learning is performed.

Generator Resolver Offset Complete Status

Displays the completion status of the resolver learning.

Displays ON when resolver learning is complete.

Motor Resolver Offset Value

Displays the resolver learning value.

Displays 0 after the inverter with converter assembly has been replaced (and learning has not been performed) or resolver initialization has been performed.

Displays the resolver installation offset amount after resolver learning is performed.

Motor Resolver Offset Complete Status

Displays the completion status of the resolver learning.

Displays ON when resolver learning is complete.

  • Related Data List Item:
    • Ready ON Status
    • Vehicle Speed
    • Shift Position
    • Accelerator Position
    • Motor Revolution
    • Generator Revolution
    • Motor Temperature
    • Generator Temperature
    • Inverter Coolant Temperature
    • Ambient Temperature
    • Atmospheric Pressure

(a) Resolver Learning

HINT:

If either of the following conditions is met, resolver learning may not be possible:

  • The inverter coolant temperature is -40 °C (-40 °F) or less.
  • The atmospheric pressure is low and the motor (MG2) temperature is high. (Wait for the motor (MG2) to cool sufficiently before performing learning.)

HINT:

After beginning resolver learning, make sure to perform the procedure until resolver learning for both the generator (MG1) and motor (MG2) are completed. (Resolver learning is complete when the resolver learning incomplete message on the multi-information is cleared.)

(1) Turn the power switch off and wait for 2 minute or more.

(2) Connect the Techstream to the DLC3.

(3) Turn the power switch on (IG).

(4) Check that the air conditioning system and power outlet socket are turned off.

(5) Check that the generator resolver learning incomplete message is displayed on the multi-information display.

(6) Turn the Techstream on.

(7) Check for DTCs make sure no DTCs are output.

(If any DTCs which may affect learning are output, resolver learning cannot be performed.)

(8) Enter the following menus: Powertrain / Motor Generator / Utility / Resolver Learning/Initialization.

Powertrain > Motor Generator > Utility

Tester Display

Resolver Learning/Initialization

(9) According to the display on the Techstream, select "Learning" to start resolver learning.

(10) Turn the power switch on (READY) and wait until the READY indicator changes from blinking to illuminated.

NOTICE:

Do not operate the accelerator pedal, shift lever or any switches until the READY indicator is illuminated.

HINT:

When the power switch is turned on (READY) during resolver learning, the engine will start.

It takes approximately 10 seconds for the READY indicator to illuminate after the power switch is turned on (READY).

(11) Check that the motor resolver learning incomplete message is displayed on the multi-information display.

(12) Move the shift lever to D.

(13) Accelerate the vehicle to between 30 km/h (19 mph) and 40 km/h (25 mph), fully release the accelerator pedal and allow the vehicle to coast for 3 seconds. (*1)

NOTICE:

Do not operate the accelerator pedal, brake pedal, shift lever or any switches while the vehicle is coasting.

HINT:

If any of the following conditions are met, resolver learning may not be possible:

  • A shift state other than D position.
  • The vehicle speed is excessively low or high.
  • The vehicle is being driven on a rough road or steep hill causing the vehicle speed to fluctuate while the vehicle is coasting.
  • The hybrid vehicle transaxle assembly temperature is excessively low.

    (If the hybrid vehicle transaxle assembly temperature is excessively low, such as (0°C (32°F) or less), the vehicle speed will decrease excessively while the vehicle is coasting. )

  • The POWER drive mode is selected.
  • The driving support system is turned on.

(14) Check that the motor resolver learning incomplete message is not displayed on the multi-information display.

HINT:

If the motor resolver learning incomplete message continues to be displayed on the multi-information display, perform step (*1) again.

(15) Stop the vehicle, turn the power switch off and wait for 1 minute or more.

(16) Turn the power switch on (READY).

(17) Check that the generator resolver learning incomplete and motor resolver learning incomplete messages are not displayed on the multi-information display.

HINT:

If the power switch is turned on (IG) after less than 1 minute has elapsed since the power switch was turned off, the learned value may not be stored correctly and the generator resolver learning incomplete or motor resolver learning incomplete message may be displayed on the multi-information display.