Last Modified: 11-20-2023 |
6.11:8.1.0 |
Doc ID: RM1000000014UN2 |
Model Year Start: 2018 |
Model: Camry HV |
Prod Date Range: [07/2017 - 09/2018] |
Title: HYBRID / BATTERY CONTROL: MOTOR GENERATOR CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY): P0C381C; DC/DC Converter Temperature Sensor "A" Circuit Voltage Out of Range; 2018 MY Camry HV [07/2017 - 09/2018] |
DTC
|
P0C381C
|
DC/DC Converter Temperature Sensor "A" Circuit Voltage Out of Range
|
DTC SUMMARY
MALFUNCTION DESCRIPTION
These DTCs indicate that the boost converter temperature sensor (upper) value is abnormal. The cause of this malfunction may be one of the following:
Internal inverter malfunction
-
Inverter with converter assembly internal circuit malfunction
Hybrid cooling system malfunction
-
Coolant circulation abnormal (frozen or leaking, etc.)
Inverter low-voltage circuit malfunction
-
The connectors are not connected properly
DESCRIPTION
The motor generator control ECU, which is built into in the inverter with converter assembly, detects the temperature of the boost converter using the temperature sensor built into the boost converter. If necessary, the motor generator control ECU will limit inverter output to help prevent boost converter overheating. The motor generator control ECU also detects malfunctions in the sensor based on the temperature sensor values.
DTC No.
|
Detection Item
|
DTC Detection Condition
|
Trouble Area
|
MIL
|
Warning Indicate
|
P0C381C
|
DC/DC Converter Temperature Sensor "A" Circuit Voltage Out of Range
|
The actual boost converter temperature (upper) high and the difference between the estimated boost converter temperature (upper) and the actual temperature exceeds a threshold for 10 seconds, or after a long soak, the boost converter temperature (upper) sensor value differs from the values of other sensors.
(1 trip detection logic)
|
-
Inverter cooling system
-
Cooling fan system
-
Grille shutter system
-
Inverter with converter assembly
-
Wire harness or connector
|
Comes on
|
Master Warning Light:
Comes on
|
Related Data List
DTC No.
|
Data List
|
P0C381C
|
-
Boosting Converter Temperature (Upper)
-
Inverter Coolant Temperature
|
MONITOR DESCRIPTION
If the motor generator control ECU detects a malfunction of the DC/DC Converter Temperature sensor "A", it will illuminate the MIL and store a DTC.
MONITOR STRATEGY
Related DTCs
|
P0C39 (INF P0C381C): DC/DC Converter Temperature Sensor "A" Range / Performance
|
Required sensors/components
|
Inverter, boost converter
|
Frequency of operation
|
Continuous
|
Duration
|
TMC's intellectual property
|
MIL operation
|
1 driving cycle
|
Sequence of operation
|
None
|
TYPICAL ENABLING CONDITIONS
The monitor will run whenever the following DTCs are not stored
|
TMC's intellectual property
|
Other conditions belong to TMC's intellectual property
|
-
|
TYPICAL MALFUNCTION THRESHOLDS
TMC's intellectual property
|
-
|
COMPONENT OPERATING RANGE
Motor generator control ECU
|
DTC P0C39 (INF P0C381C) is not detected
|
CONFIRMATION DRIVING PATTERN
HINT:
-
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click here
-
When clearing the permanent DTCs, refer to the "CLEAR PERMANENT DTC" procedure.
Click here
-
Connect the Techstream to the DLC3.
-
Turn the power switch on (IG) and turn the Techstream on.
-
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
-
Turn the power switch off and wait for 2 minutes or more.
-
Turn the power switch on (IG) and turn the Techstream on.
-
Turn the power switch on (READY) and wait for 90 seconds or more with the vehicle in EV drive mode. [*1]
HINT:
Check that there are no abnormalities (abnormal sounds, coolant leaks, DTC output, etc.).
-
Drive the vehicle for approximately 10 minutes with the value of Data List item "Inverter Coolant Temperature" 25°C (77°F) or more. [*2]
HINT:
[*1] to [*2]: Normal judgment procedure.
The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.
-
Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
-
Check the DTC judgment result.
HINT:
-
If the judgment result shows NORMAL, the system is normal.
-
If the judgment result shows ABNORMAL, the system has a malfunction.
-
If the judgment result shows INCOMPLETE or N/A, perform the normal judgment procedure again.
WIRING DIAGRAM
Refer to the wiring diagram for the Cooling System.
Click here
CAUTION / NOTICE / HINT
CAUTION:
NOTICE:
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click here
PROCEDURE
1.
|
CHECK DTC OUTPUT (HYBRID CONTROL)
|
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
(d) Check for DTCs.
Powertrain > Hybrid Control > Trouble Codes
Result
|
Proceed to
|
P0C381C only is output, or DTCs except the ones in the table below are also output.
|
A
|
Any of the following DTCs are also output.
|
B
|
Table 1
Malfunction Content
|
Relevant DTC
|
Insulation Malfunction
|
P1C7C49
|
Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure
|
P1C7D49
|
Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure
|
P1C7E49
|
Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure
|
P1C7F49
|
Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure
|
Table 2
Malfunction Content
|
Relevant DTC
|
Sensor and actuator circuit malfunction
|
P0C7396
|
Motor Electronics Coolant Pump "A" Component Internal Failure
|
P314A31
|
Motor Electronics Coolant Pump "A" No Signal
|
System malfunction
|
P0A9300
|
Inverter "A" Cooling System
|
HINT:
-
P0C381C may be output as a result of the malfunction indicated by the DTCs above.
-
The chart above is listed in inspection order of priority.
-
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
(e) Turn the power switch off.
A
|
|
|
2.
|
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
|
Click here
Result
|
Proceed to
|
OK
|
A
|
NG (The connector is not connected securely.)
|
B
|
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.)
|
C
|
B |
|
CONNECT SECURELY
|
C |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
A
|
|
|
Click here
HINT:
If the "Cooling System" inspection results are normal, perform the next step.
|