Last Modified: 11-20-2023 |
6.11:8.1.0 |
Doc ID: RM1000000014U4Y |
Model Year Start: 2018 |
Model: Camry HV |
Prod Date Range: [07/2017 - 09/2018] |
Title: NETWORKING: CAN COMMUNICATION SYSTEM: Open in Bus 1 Main Bus Line; 2018 MY Camry HV [07/2017 - 09/2018] |
Open in Bus 1 Main Bus Line
|
DESCRIPTION
There may be an open circuit in one of the CAN main bus lines when the resistance between terminals 23 (CA1H) and 8 (CA1L) of the central gateway ECU (network gateway ECU) is 70 Ω or higher.
Symptom
|
Trouble Area
|
Resistance between terminals 23 (CA1H) and 8 (CA1L) of the central gateway ECU (network gateway ECU) is 70 Ω or higher.
|
-
CAN main bus lines or connector
-
Central gateway ECU (network gateway ECU)
-
No. 1 CAN junction connector
-
No. 5 CAN junction connector
|
This malfunction is not related to the lines of a CAN branch or to ECUs or sensors connected to a CAN branch.
WIRING DIAGRAM
CAUTION / NOTICE / HINT
CAUTION:
When performing the confirmation driving pattern, obey all speed limits and traffic laws.
HINT:
-
Before disconnecting related connectors for inspection, push in on each connector body to check that the connector is not loose or disconnected.
-
When a connector is disconnected, check that the terminals and connector body are not cracked, deformed or corroded.
PROCEDURE
1.
|
CHECK FOR OPEN IN CAN MAIN BUS LINES (NO. 1 CAN JUNCTION CONNECTOR)
|
(a) Disconnect the cable from the negative (-) auxiliary battery terminal.
(b) Disconnect the A66 No. 1 CAN junction connector.
(c) Measure the resistance according to the value(s) in the table below.
*a
|
Front view of wire harness connector
(to No. 1 CAN Junction Connector)
|
*b
|
to Central Gateway ECU (Network Gateway ECU)
|
*c
|
to No. 5 CAN Junction Connector
|
-
|
-
|
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
Connected to
|
A66-3 (CANH) - A66-9 (CANL)
|
Cable disconnected from negative (-) auxiliary battery terminal
|
108 to 132 Ω
|
Central gateway ECU (network gateway ECU)
|
A66-5 (CANH) - A66-11 (CANL)
|
Cable disconnected from negative (-) auxiliary battery terminal
|
108 to 132 Ω
|
No. 5 CAN junction connector
|
Result
|
Proceed to
|
OK
|
A
|
NG (Line to central gateway ECU (network gateway ECU))
|
B
|
NG (Line to No. 5 CAN junction connector)
|
C
|
A |
|
REPLACE NO. 1 CAN JUNCTION CONNECTOR
|
B
|
|
|
2.
|
CHECK FOR OPEN IN CAN MAIN BUS LINES (CENTRAL GATEWAY ECU (NETWORK GATEWAY ECU) - NO. 1 CAN JUNCTION CONNECTOR)
|
(a) Reconnect the A66 No. 1 CAN junction connector.
(b) Disconnect the K76 central gateway ECU (network gateway ECU) connector.
(c) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
K76-23 (CA1H) - K76-9 (CAXH)
|
Cable disconnected from negative (-) auxiliary battery terminal
|
Below 1 Ω
|
K76-8 (CA1L) - K76-24 (CAXL)
|
Cable disconnected from negative (-) auxiliary battery terminal
|
Below 1 Ω
|
|
|
*a
|
Front view of wire harness connector
(to Central Gateway ECU (Network Gateway ECU))
|
|
|
NG |
|
REPAIR OR REPLACE CAN MAIN BUS LINES OR CONNECTOR (CENTRAL GATEWAY ECU (NETWORK GATEWAY ECU) - NO. 1 CAN JUNCTION CONNECTOR)
|
3.
|
CHECK FOR OPEN IN CAN MAIN BUS LINES (NO. 5 CAN JUNCTION CONNECTOR)
|
(a) Reconnect the A66 No. 1 CAN junction connector.
(b) Disconnect the R98 No. 5 CAN junction connector.
(c) Measure the resistance according to the value(s) in the table below.
*a
|
Front view of wire harness connector
(to No. 5 CAN Junction Connector)
|
*b
|
to Central Gateway ECU (Network Gateway ECU)
|
*c
|
to No. 1 CAN Junction Connector
|
-
|
-
|
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
Connected to
|
R98-1 (CANH) - R98-11 (CANL)
|
Cable disconnected from negative (-) auxiliary battery terminal
|
108 to 132 Ω
|
Central gateway ECU (network gateway ECU)
|
R98-5 (CANH) - R98-15 (CANL)
|
Cable disconnected from negative (-) auxiliary battery terminal
|
108 to 132 Ω
|
No. 1 CAN junction connector
|
Result
|
Proceed to
|
OK
|
A
|
NG (Line to No. 1 CAN junction connector)
|
B
|
NG (Line to central gateway ECU (network gateway ECU))
|
C
|
A |
|
REPLACE NO. 5 CAN JUNCTION CONNECTOR
|
B |
|
REPAIR OR REPLACE CAN MAIN BUS LINES OR CONNECTOR (NO. 5 CAN JUNCTION CONNECTOR - NO. 1 CAN JUNCTION CONNECTOR)
|
C
|
|
|
4.
|
CHECK FOR OPEN IN CAN MAIN BUS LINES (CENTRAL GATEWAY ECU (NETWORK GATEWAY ECU) - NO. 5 CAN JUNCTION CONNECTOR)
|
(a) Reconnect the R98 No. 5 CAN junction connector.
(b) Disconnect the K76 central gateway ECU (network gateway ECU) connector.
(c) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
K76-23 (CA1H) - K76-9 (CAXH)
|
Cable disconnected from negative (-) auxiliary battery terminal
|
Below 1 Ω
|
K76-8 (CA1L) - K76-24 (CAXL)
|
Cable disconnected from negative (-) auxiliary battery terminal
|
Below 1 Ω
|
|
|
*a
|
Front view of wire harness connector
(to Central Gateway ECU (Network Gateway ECU))
|
|
|
NG |
|
REPAIR OR REPLACE CAN MAIN BUS LINES OR CONNECTOR (CENTRAL GATEWAY ECU (NETWORK GATEWAY ECU) - NO. 5 CAN JUNCTION CONNECTOR)
|
|