Last Modified: 11-20-2023 |
6.11:8.1.0 |
Doc ID: RM100000001R3ZW |
Model Year Start: 2021 |
Model: Camry |
Prod Date Range: [10/2020 -
] |
Title: HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM (for Manual Air Conditioning System): Cooling System; 2021 - 2024 MY Camry [10/2020 - ] |
DESCRIPTION
If the cooling effect of the air conditioning system is weak, the following suspected areas may be the cause.
Symptom
|
Factor
|
-
Cooling effectiveness is poor
-
Cooling response is slow
|
-
Compressor assembly with pulley (compressor solenoid) malfunction
-
Air conditioning amplifier assembly malfunction
-
Refrigerant volume (high)
-
Refrigerant volume (low)
-
Clogged cooler condenser assembly fins
-
Cooling fan system malfunction
-
Mechanical locking of damper and damper link
-
High inlet air temperature
|
PROCEDURE
1.
|
PERFORM REFRIGERANT SHORTAGE CHECK
|
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Air Conditioner / Utility / Refrigerant Gas Volume Check.
Body Electrical > Air Conditioner > Utility
Tester Display
|
Refrigerant Gas Volume Check
|
(e) Check that the following conditions are met and perform the refrigerant shortage check according to the display on the Techstream.
Measurement Condition:
Item
|
Condition
|
A/C switch
|
On
|
Ambient temperature*
|
0 to 49°C (32 to 120°F)
|
Blower speed
|
HI
|
*: If the ambient temperature is not within the range shown, do not perform this check.
Result
|
Amount of Refrigerant
|
Refrigerant correct
|
Correct
|
Refrigerant shortage
|
Insufficient
|
OK:
"Refrigerant correct" is displayed on Techstream.
OK
|
|
|
2.
|
PERFORM ACTIVE TEST USING TECHSTREAM
|
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Air Conditioner / Active Test.
(e) Perform the Active Test according to the display on the Techstream.
Body Electrical > Air Conditioner > Active Test
Tester Display
|
Measurement Item
|
Control Range
|
Diagnostic Note
|
Blower Motor
|
Blower motor with fan sub-assembly
|
Min.: 0
Max.: 31
|
-
|
Air Mix Servo Targ Pulse(D)
|
No. 1 air conditioning radiator damper servo sub-assembly (air mix) pulse
|
Min.: 128
Max.: 383
|
Operates between 165 to 257 pulses
|
Air Outlet Servo Pulse (D)
|
No. 1 air conditioning radiator damper servo sub-assembly (mode) pulse
|
Min.: 128
Max.: 383
|
Operates between 241 to 348 pulses
|
Air Inlet Damper Targ Pulse
|
No. 1 blower damper servo sub-assembly pulse
|
Min.: 128
Max.: 383
|
Operates between 220 to 256 pulses
|
Body Electrical > Air Conditioner > Active Test
Tester Display
|
Blower Motor
|
Body Electrical > Air Conditioner > Active Test
Tester Display
|
Air Mix Servo Targ Pulse(D)
|
Body Electrical > Air Conditioner > Active Test
Tester Display
|
Air Outlet Servo Pulse (D)
|
Body Electrical > Air Conditioner > Active Test
Tester Display
|
Air Inlet Damper Targ Pulse
|
OK:
The blower motor with fan sub-assembly and each damper servo motor operates.
|