Last Modified: 11-20-2023 |
6.11:8.1.0 |
Doc ID: RM100000001JY7L |
Model Year Start: 2020 |
Model: Camry |
Prod Date Range: [09/2019 -
] |
Title: NETWORKING: CAN COMMUNICATION SYSTEM: Restraints Occupant Classification System Module Communication Stop Mode; 2020 - 2024 MY Camry [09/2019 - ] |
Restraints Occupant Classification System Module Communication Stop Mode
|
DESCRIPTION
Detection Item
|
Symptom
|
Trouble Area
|
Restraints Occupant Classification System Module Communication Stop Mode
|
Any of the following conditions are met:
|
-
Occupant detection ECU branch line or connector
-
Power source circuit of occupant detection ECU
-
Occupant detection ECU ground circuit
-
Occupant detection ECU
|
WIRING DIAGRAM
CAUTION / NOTICE / HINT
CAUTION:
When performing the confirmation driving pattern, obey all speed limits and traffic laws.
HINT:
-
Before disconnecting related connectors for inspection, push in on each connector body to check that the connector is not loose or disconnected.
-
When a connector is disconnected, check that the terminals and connector body are not cracked, deformed or corroded.
PROCEDURE
1.
|
CHECK FOR OPEN IN CAN BUS LINES (OCCUPANT DETECTION ECU BRANCH LINE)
|
(a) Disconnect the cable from the negative (-) battery terminal.
(b) Disconnect the a6 occupant detection ECU connector.
(c) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
a6-5 (CANP) - a6-4 (CANN)
|
Cable disconnected from negative (-) battery terminal
|
54 to 69 Ω
|
|
|
*a
|
Front view of wire harness connector
(to Occupant Detection ECU)
|
|
|
NG |
|
REPAIR OR REPLACE CAN BRANCH LINES OR CONNECTOR (OCCUPANT DETECTION ECU)
|
OK
|
|
|
2.
|
CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
|
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
a6-10 (GND) - Body ground
|
Cable disconnected from negative (-) battery terminal
|
Below 1 Ω
|
|
|
*a
|
Front view of wire harness connector
(to Occupant Detection ECU)
|
|
|
(b) Reconnect the cable to the negative (-) battery terminal.
(c) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
|
Condition
|
Specified Condition
|
a6-6 (IG2) - Body ground
|
Ignition switch ON
|
11 to 14 V
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR (POWER SOURCE CIRCUIT)
|
|