Last Modified: 11-20-2023 |
6.11:8.1.0 |
Doc ID: RM1000000015P6L |
Model Year Start: 2018 |
Model: Camry |
Prod Date Range: [06/2017 - 10/2020] |
Title: SUPPLEMENTAL RESTRAINT SYSTEMS: FRONT PASSENGER AIRBAG ASSEMBLY: REMOVAL; 2018 - 2020 MY Camry [06/2017 - 10/2020] |
REMOVAL
CAUTION / NOTICE / HINT
The necessary procedures (adjustment, calibration, initialization or registration) that must be performed after parts are removed and installed, or replaced during instrument panel passenger airbag assembly removal/installation are shown below.
Necessary Procedures After Parts Removed/Installed/Replaced
Replaced Part or Performed Procedure
|
Necessary Procedure
|
Effect/Inoperative Function when Necessary Procedure not Performed
|
Link
|
Disconnect cable from negative battery terminal
|
Perform steering sensor zero point calibration
|
Lane departure alert system (w/ Steering Control)
|
|
Pre-collision system
|
Intelligent clearance sonar system*
|
Memorize steering angle neutral point
|
Parking assist monitor system
|
|
Panoramic view monitor system
|
|
PROCEDURE
1. PRECAUTION
CAUTION:
Be sure to read Precaution thoroughly before servicing.
Click here
NOTICE:
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notices before proceeding with work.
Click here
2. REMOVE NO. 1 INSTRUMENT PANEL REGISTER ASSEMBLY
Click here
3. DISCONNECT NO. 5 INSTRUMENT PANEL WIRE
(a) Check that the ignition switch is off.
(b) Check that the cable is disconnected from the negative (-) battery terminal.
CAUTION:
Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to disable the SRS system.
(c) Slide the slider to release the lock, and then disconnect the connector.
*a
|
Slider
|
|
Release in this Direction
|
NOTICE:
When disconnecting any airbag connector, take care not to damage the airbag wire harness.
4. REMOVE INSTRUMENT PANEL SAFETY PAD SUB-ASSEMBLY
Click here
5. REMOVE INSTRUMENT PANEL PASSENGER AIRBAG ASSEMBLY
CAUTION:
When storing the instrument panel passenger airbag assembly, keep the airbag deployment side facing upward.
|
Deployment Side
|
(a) Remove the 2 screws and disengage the clamp.
|
|
(b) Using a screwdriver, pry back the passenger airbag door retainer to disengage the 3 hooks as shown in the illustration.
*a
|
Passenger Airbag Door Retainer
|
|
Move the screwdriver in this Direction
|
NOTICE:
Do not damage the deployment surface of the instrument panel passenger airbag assembly.
(c) Disengage the 3 hooks to remove the instrument panel passenger airbag assembly from the instrument panel safety pad sub-assembly.
|
|
6. REMOVE NO. 5 INSTRUMENT PANEL WIRE
(a) Using a screwdriver with its tip wrapped with protective tape, release the 2 airbag connector locking buttons.
*a
|
Protective Tape
|
*b
|
Airbag Connector
|
*c
|
Airbag Connector Locking Button
|
|
Release in this Direction
|
(b) Disconnect the 2 airbag connectors to remove the No. 5 instrument panel wire from the instrument panel passenger airbag assembly.
NOTICE:
When disconnecting any airbag connector, take care not to damage the airbag wire harness.
|