| A33-1 (+BM) - Body ground | B - Body ground | ABS motor relay power supply | Always | 11 to 14 V | 
                        
                           | A33-3 (STPO) - Body ground*2 | L - Body ground | Stop light control relay (stop light switch assembly) output | Always | 11 to 14 V | 
                        
                           | A33-9 (CSW) - Body ground | P - Body ground | VSC OFF switch input | VSC OFF switch on → off (Pressed → not pressed) | Below 1 Ω → 10 kΩ or higher | 
                        
                           | A33-13 (GND2) - Body ground | W-B - Body ground | Pump motor ground | Always | Below 1 Ω | 
                        
                           | A33-22 (STP2) - Body ground*2 | R - Body ground | Stop light control relay (stop light switch assembly) input | Stop light switch assembly on → off (Brake pedal depressed → released) | (+BS x 0.85) to 14 V*1 → Below 1.5 V | 
                        
                           | A33-25 (+BS) - Body ground | L - Body ground | ABS solenoid relay power supply | Always | 11 to 14 V | 
                        
                           | A33-28 (IG1) - Body ground | B - Body ground | IG1 power source input | Ignition switch ON | 11 to 14 V | 
                        
                           | A33-30 (STP) - Body ground | GR - Body ground | Stop light switch assembly input | Stop light switch assembly on → off (Brake pedal depressed → released) | (+BS x 0.85) to 14 V*1 → Below 1.5 V | 
                        
                           | A33-38 (GND1) - Body ground | W-B - Body ground | Skid control ECU (brake actuator assembly) ground | Always | Below 1 Ω |