Last Modified: 11-20-2023 |
6.11:8.1.0 |
Doc ID: RM1000000014YGF |
Model Year Start: 2018 |
Model: Camry |
Prod Date Range: [06/2017 -
] |
Title: 2GR-FKS (COOLING): THERMOSTAT: INSPECTION; 2018 - 2024 MY Camry [06/2017 - ] |
INSPECTION
PROCEDURE
1. INSPECT WATER INLET WITH THERMOSTAT SUB-ASSEMBLY
(a) Check the valve opening.
HINT:
The valve opening temperature is inscribed on the water inlet with thermostat sub-assembly.
(1) Add 15 cc (0.9 cu. in.) of water to the water inlet with thermostat sub-assembly from the inlet pipe side.
|
|
*a
|
Inlet Pipe Side
|
*b
|
Valve Side
|
|
|
(2) Confirm that water does not flow out from the valve side of the water inlet with thermostat sub-assembly.
If water flows out from the valve side of the water inlet with thermostat sub-assembly, replace the water inlet with thermostat sub-assembly with a new one.
(3) Immerse the water inlet with thermostat sub-assembly in water that is between 92°C (198°F) and 96°C (205°F) for 5 minutes or more.
NOTICE:
-
Do not allow any water to come into contact with the connector of the water inlet with thermostat sub-assembly.
-
Make sure that the end of the inlet pipe of the water inlet with thermostat sub-assembly is not facing downward.
-
Make sure to immerse the water inlet with thermostat sub-assembly in the water as shown in the illustration.
*a
|
Connector
|
*b
|
Inlet Pipe
|
|
Temperature Sensor
|
(4) Leave the water inlet with thermostat sub-assembly at ambient temperature for 5 minutes so that the valve closes.
NOTICE:
Make sure that the end of the inlet pipe of the water inlet with thermostat sub-assembly is not facing downward.
|
|
(5) Check that the water that was added to the water inlet with thermostat sub-assembly has completely flowed out.
If the water that was added to the water inlet with thermostat sub-assembly has not completely flowed out, replace the water inlet with thermostat sub-assembly with a new one.
(b) Check the resistance of the temperature sensor.
(1) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
1 - 2
|
Always
|
10.6 to 14.2 Ω
|
If the result is not as specified, replace the water inlet with thermostat sub-assembly.
|