                        | Last Modified: 11-20-2023 | 6.11:8.1.0 | Doc ID: RM1000000014VIZ |  
                        | Model Year Start: 2018 | Model: Camry | Prod Date Range: [06/2017 - 08/2018] |  
                        | Title: 2GR-FKS (ENGINE CONTROL): SFI SYSTEM: P03652A,P036531,P039031; Camshaft Position Sensor "B" Bank 1 Signal Stuck in Range; 2018 MY Camry [06/2017 - 08/2018] |  
                     
                        
                           | DTC | P03652A | Camshaft Position Sensor "B" Bank 1 Signal Stuck in Range |  
                     
                        
                           | DTC | P036531 | Camshaft Position Sensor "B" Bank 1 No Signal |  
                     
                        
                           | DTC | P039031 | Camshaft Position Sensor "B" Bank 2 No Signal |  DESCRIPTIONRefer to DTC P036511. Click here
                        
                           
                              ![2018 MY Camry [06/2017 - 08/2018]; 2GR-FKS (ENGINE CONTROL): SFI SYSTEM: P036511,P036515,P039011,P039015; Camshaft Position Sensor "B" Bank 1 Circuit Short to Ground](/t3Portal/stylegraphics/info.gif)  
                     
                        
                        
                        
                        
                        
                        
                        
                     
                     
                        
                           | DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory | Note |  
                           | P03652A | Camshaft Position Sensor "B" Bank 1 Signal Stuck in Range | No VVT sensor (for exhaust camshaft of bank 1) signal to ECM while engine cranking (1 trip detection logic). | 
                                 
                                    
Open or short in VVT sensor (for exhaust camshaft of bank 1) circuit
VVT sensor (for exhaust camshaft of bank 1)
Exhaust camshaft
Valve timing
ECM
 | Comes on | DTC stored | SAE Code: P0365 DTC for Mexico Models: Applies |  
                           | P036531 | Camshaft Position Sensor "B" Bank 1 No Signal | No VVT sensor (for exhaust camshaft of bank 1) signal for 5 seconds at an engine speed of 600 rpm or higher (1 trip detection logic). | 
                                 
                                    
Open or short in VVT sensor (for exhaust camshaft of bank 1) circuit
VVT sensor (for exhaust camshaft of bank 1)
Exhaust camshaft
Valve timing
ECM
 | Comes on | DTC stored | SAE Code: P0365 DTC for Mexico Models: Applies |  
                           | P039031 | Camshaft Position Sensor "B" Bank 2 No Signal | No VVT sensor (for exhaust camshaft of bank 2) signal for 5 seconds at an engine speed of 600 rpm or higher (1 trip detection logic). | 
                                 
                                    
Open or short in VVT sensor (for exhaust camshaft of bank 2) circuit
VVT sensor (for exhaust camshaft of bank 2)
Exhaust camshaft
Valve timing
ECM
 | Comes on | DTC stored | SAE Code: P0390 DTC for Mexico Models: Applies |  Reference: Inspection using an oscilloscope. Click here
                        
                           
                              ![2018 MY Camry [06/2017 - 08/2018]; 2GR-FKS (ENGINE CONTROL): SFI SYSTEM: P034011,P034015,P034511,P034515; Camshaft Position Sensor "A" Bank 1 or Single Sensor Circuit Short to Ground](/t3Portal/stylegraphics/info.gif)  MONITOR DESCRIPTIONIf no pulse signal is transmitted by the VVT sensor (for exhaust camshaft) despite the camshaft rotating, or the rotation of the camshaft and the crankshaft is not synchronized, the ECM interprets this as a malfunction of the sensor. MONITOR STRATEGY
                     
                        
                        
                     
                     
                        
                           | Related DTCs | P0365: Exhaust VVT sensor (bank 1) verify pulse input P0390: Exhaust VVT sensor (bank 2) verify pulse input |  
                           | Required Sensors/Components (Main) | VVT sensor (for exhaust camshaft) |  
                           | Required Sensors/Components (Related) | Crankshaft position sensor |  
                           | Frequency of Operation | Continuous |  
                           | Duration | 2 times: P0365 (case 1) 5 seconds: P0365 (case 2), P0390 |  
                           | MIL Operation | Immediate |  
                           | Sequence of Operation | None |  TYPICAL ENABLING CONDITIONSP0365: Exhaust VVT Sensor (Bank 1) Verify Pulse Input (Case 1)
                     
                        
                        
                     
                     
                        
                           | Monitor runs whenever the following DTCs are not stored | None |  
                           | Both of the following conditions are met | - |  
                           | Starter | After off to on timing |  
                           | Minimum battery voltage while starter on | Less than 11 V |  P0365: Exhaust VVT Sensor (Bank 1) Verify Pulse Input (Case 2)
                     
                        
                        
                     
                     
                        
                           | All of the following conditions are met | - |  
                           | Engine speed | 600 rpm or higher |  
                           | Exhaust VVT sensor range check fail (P0367, P0368) | Not detected |  
                           | Engine switch | On (IG) |  
                           | Starter | Off |  
                           | Battery voltage | 8 V or higher |  
                           | Exhaust VVT sensor voltage | 0.3 to 4.7 V |  P0390: Exhaust VVT Sensor (Bank 2) Verify Pulse Input
                     
                        
                        
                     
                     
                        
                           | All of the following conditions are met | - |  
                           | Engine speed | 600 rpm or higher |  
                           | Exhaust VVT sensor range check fail (P0392, P0393) | Not detected |  
                           | Engine switch | On (IG) |  
                           | Starter | Off |  
                           | Battery voltage | 8 V or higher |  
                           | Exhaust VVT sensor voltage | 0.3 to 4.7 V |  TYPICAL MALFUNCTION THRESHOLDS
                     
                        
                        
                     
                     
                        
                           | Exhaust VVT sensor signal | No signal |  CONFIRMATION DRIVING PATTERN
                     HINT: 
                        
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click here
                                 
                                    
                                       ![2018 - 2024 MY Camry [06/2017 -        ]; 2GR-FKS (ENGINE CONTROL): SFI SYSTEM: DTC CHECK / CLEAR](/t3Portal/stylegraphics/info.gif) 
When clearing the permanent DTCs, refer to the "CLEAR PERMANENT DTC" procedure.
Click here
                                 
                                    
                                       ![2018 - 2024 MY Camry [06/2017 -        ]; 2GR-FKS (ENGINE CONTROL): SFI SYSTEM: DTC CHECK / CLEAR](/t3Portal/stylegraphics/info.gif)  
                     
                        
Connect the Techstream to the DLC3.
Turn the engine switch on (IG).
Turn the Techstream on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the engine switch off and wait for at least 30 seconds.
Start the engine [A].
Idle the engine for 10 seconds or more [B].
Turn the Techstream on.
Enter the following menus: Powertrain / Engine / Trouble Codes [C].
Read the pending DTCs.
                              HINT: 
                                 
If a pending DTC is output, the system is malfunctioning.
If a pending DTC is not output, perform the following procedure.
Enter the following menus: Powertrain / Engine / Utility / All Readiness.
Input the DTC: P03652A, P036531 or P039031.
Check the DTC judgment result.
                              
                                 
                                 
                              
                              
                                 
                                    | Techstream Display | Description |  
                                    | NORMAL | 
                                          
                                             
DTC judgment completed
System normal
 |  
                                    | ABNORMAL | 
                                          
                                             
DTC judgment completed
System abnormal
 |  
                                    | INCOMPLETE | 
                                          
                                             
DTC judgment not completed
Perform driving pattern after confirming DTC enabling conditions
 |  WIRING DIAGRAMRefer to DTC P036511. Click here
                        
                           
                              ![2018 MY Camry [06/2017 - 08/2018]; 2GR-FKS (ENGINE CONTROL): SFI SYSTEM: P036511,P036515,P039011,P039015; Camshaft Position Sensor "B" Bank 1 Circuit Short to Ground](/t3Portal/stylegraphics/info.gif)  CAUTION / NOTICE / HINT
                     HINT: 
                        
If no problem is found through this diagnostic troubleshooting procedure, there may be a mechanical problem with the engine.
Read Freeze Frame Data using the Techstream. The ECM records vehicle and driving condition information as Freeze Frame Data the moment a DTC is stored. When troubleshooting, Freeze Frame Data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.
 PROCEDURE
                     
                        
                           | 1.  | CHECK HARNESS AND CONNECTOR |    
                     
                        
                        
                     
                     
                        
                           | *a | Front view of wire harness connector (to VVT Sensor (for Exhaust Camshaft)) |  
                           | *b | Bank 1 |  
                           | *c | Bank 2 |  HINT: Make sure that the connector is properly connected. If it is not, securely connect it and check for DTCs again. (a) Disconnect the VVT sensor (for exhaust camshaft) connector. (b) Turn the engine switch on (IG). (c) Measure the voltage according to the value(s) in the table below. Standard Voltage:  
                     
                        
                        
                        
                     
                     
                        
                           | Tester Connection | Condition | Specified Condition |  
                           | C20-3 (VC2) - Body ground | Engine switch on (IG) | 4.5 to 5.5 V |  
                           | C21-3 (VC2) - Body ground | Engine switch on (IG) | 4.5 to 5.5 V |  
                           | C20-1 (EX+) - Body ground | Engine switch on (IG) | 3.0 to 5.0 V |  
                           | C21-1 (EX+) - Body ground | Engine switch on (IG) | 3.0 to 5.0 V |  (d) Turn the engine switch off and wait for at least 30 seconds. (e) Measure the resistance according to the value(s) in the table below. Standard Resistance:  
                     
                        
                        
                        
                     
                     
                        
                           | Tester Connection | Condition | Specified Condition |  
                           | C20-3 (VC2) - C20-1 (EX+) | Engine switch off | 1.425 to 1.575 kΩ |  
                           | C21-3 (VC2) - C21-1 (EX+) | Engine switch off | 1.425 to 1.575 kΩ |  
                           | C20-2 (EX-) - Body ground | Always | Below 1 Ω |  
                           | C21-2 (EX-) - Body ground | Always | Below 1 Ω |  
                     
                        | 
                              
                                 | OK |  
                                 |   |  |  
                     
                        
                           | 2.  | CHECK SENSOR INSTALLATION AND CONDUCT VISUAL INSPECTION (VVT SENSOR (FOR EXHAUST CAMSHAFT)) |    (a) Visually check the VVT sensor (for exhaust camshaft) for damage. (b) Check the VVT sensor (for exhaust camshaft) installation condition. OK:  The VVT sensor (for exhaust camshaft) does not have any damage and is installed properly. 
                     
                        | 
                              
                                 | OK |  
                                 |   |  |  
                     
                        
                           | 3.  | INSPECT EXHAUST CAMSHAFT (TIMING ROTOR) |  (a) Check the timing rotor of the exhaust camshaft. OK:  Camshaft timing rotor does not have any cracks or deformation. HINT: Perform "Inspection After Repair" after replacing the exhaust camshaft. Click here
                        
                           
                              ![2018 MY Camry [06/2017 - 08/2018]; 2GR-FKS (ENGINE CONTROL): SFI SYSTEM: INITIALIZATION](/t3Portal/stylegraphics/info.gif)  
                     
                        
                           | 4.  | CHECK HARNESS AND CONNECTOR (VVT SENSOR (FOR EXHAUST CAMSHAFT) - ECM) |  (a) Disconnect the VVT sensor (for exhaust camshaft) connector. (b) Disconnect the ECM connector. (c) Measure the resistance according to the value(s) in the table below. Standard Resistance:  
                     
                        
                        
                        
                     
                     
                        
                           | Tester Connection | Condition | Specified Condition |  
                           | C20-1 (EX+) - C96-131 (EV1+) | Always | Below 1 Ω |  
                           | C20-2 (EX-) - C96-100 (VV1-) | Always | Below 1 Ω |  
                           | C20-3 (VC2) - C96-99 (VCV1) | Always | Below 1 Ω |  
                           | C21-1 (EX+) - C96-130 (EV2+) | Always | Below 1 Ω |  
                           | C21-2 (EX-) - C96-97 (VV2-) | Always | Below 1 Ω |  
                           | C21-3 (VC2) - C96-98 (VCV2) | Always | Below 1 Ω |  
                           | C20-1 (EX+) or C96-131 (EV1+) - Body ground and other terminals | Always | 10 kΩ or higher |  
                           | C20-2 (EX-) or C96-100 (VV1-) - Body ground and other terminals | Always | 10 kΩ or higher |  
                           | C20-3 (VC2) or C96-99 (VCV1) - Body ground and other terminals | Always | 10 kΩ or higher |  
                           | C21-1 (EX+) or C96-130 (EV2+) - Body ground and other terminals | Always | 10 kΩ or higher |  
                           | C21-2 (EX-) or C96-97 (VV2-) - Body ground and other terminals | Always | 10 kΩ or higher |  
                           | C21-3 (VC2) or C96-98 (VCV2) - Body ground and other terminals | Always | 10 kΩ or higher |  
                     
                        
                           | NG |   | REPAIR OR REPLACE HARNESS OR CONNECTOR |  |