ON-VEHICLE INSPECTION
PROCEDURE
1. INSPECT H-LP LH RELAY
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
3 - 5
|
Voltage not applied between terminals 1 and 2
|
10 kΩ or higher
|
3 - 5
|
Voltage applied between terminals 1 and 2
|
Below 1 Ω
|
If the result is not as specified, replace the H-LP LH relay.
2. INSPECT H-LP RH RELAY
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
3 - 5
|
Voltage not applied between terminals 1 and 2
|
10 kΩ or higher
|
3 - 5
|
Voltage applied between terminals 1 and 2
|
Below 1 Ω
|
If the result is not as specified, replace the H-LP RH relay.
3. INSPECT DIM RELAY
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
3 - 5
|
Voltage not applied between terminals 1 and 2
|
10 kΩ or higher
|
3 - 5
|
Voltage applied between terminals 1 and 2
|
Below 1 Ω
|
If the result is not as specified, replace the DIM relay.
4. INSPECT DRL RELAY (for LED Type Turn Signal Light)
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
3 - 5
|
Voltage not applied between terminals 1 and 2
|
10 kΩ or higher
|
3 - 5
|
Voltage applied between terminals 1 and 2
|
Below 1 Ω
|
If the result is not as specified, replace the DRL relay.
|