Last Modified: 11-20-2023 |
6.11:8.1.0 |
Doc ID: RM1000000013PZF |
Model Year Start: 2018 |
Model: Camry |
Prod Date Range: [03/2017 -
] |
Title: HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System): Pressure Sensor Circuit; 2018 - 2024 MY Camry [03/2017 - ] |
DESCRIPTION
Based on signals from the air conditioner pressure sensor, the air conditioning amplifier assembly controls the compressor assembly with pulley (compressor solenoid)*1 or cooler compressor assembly (compressor solenoid)*2 and changes the air inlet mode between fresh and recirculation in order to protect the parts of the refrigerant cycle.
-
*1: for A25A-FKS
-
*2: for 2GR-FKS
WIRING DIAGRAM
PROCEDURE
1.
|
CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
|
*a
|
Front view of wire harness connector
(to Air Conditioner Pressure Sensor)
|
(a) Disconnect the A18 air conditioner pressure sensor connector.
(b) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
|
Condition
|
Specified Condition
|
A18-3 (+) - Body ground
|
Ignition switch ON
|
4.75 to 5.25 V
|
OK
|
|
|
2.
|
CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - BODY GROUND)
|
*a
|
Front view of wire harness connector
(to Air Conditioner Pressure Sensor)
|
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
A18-1 (-) - Body ground
|
Always
|
Below 1 Ω
|
OK
|
|
|
3.
|
CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
|
(a) Disconnect the K55 air conditioning amplifier assembly connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
A18-2 (PR) - K55-24 (PRE)
|
Always
|
Below 1 Ω
|
A18-2 (PR) or K55-24 (PRE) - Other terminals and body ground
|
Always
|
10 kΩ or higher
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
OK
|
|
|
4.
|
INSPECT AIR CONDITIONER PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)
|
*a
|
Component with harness connected
(Air Conditioning Amplifier Assembly)
|
(a) Measure the voltage with the following conditions met.
Measurement Condition:
Item
|
Condition
|
Vehicle doors
|
Fully open
|
Temperature setting
|
MAX COLD
|
Blower speed
|
HI
|
A/C switch
|
On
|
Recirculation/fresh switch
|
RECIRCULATION
|
Interior temperature
|
25 to 35°C (77 to 95°F)
|
NOTICE:
-
If refrigerant pressure on the high pressure side becomes extremely high during the inspection (if the voltage exceeds 4.61 V), a fail-safe function will stop compressor operation. In this case, make sure to measure the voltage before the fail-safe function operates.
-
It is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the malfunction may recur after a while.
HINT:
When the ambient air temperature is low (below -1.5°C (29.3°F)), the compressor with pulley will be stopped, due to inputs of the thermistor assembly and No. 1 cooler thermistor, to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.
(1) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
|
Condition
|
Specified Condition
|
K55-24 (PRE) - Body ground
|
Ignition switch ON
(A/C switch: On)
|
0.74 to 4.61 V
|
(b) Connect the Techstream to the DLC3.
(c) Turn the ignition switch to ON.
(d) Turn the Techstream on.
(e) Enter the following menus: Body Electrical / Air Conditioner / Data List.
(f) Read the Data List according to the display on the Techstream.
Body Electrical > Air Conditioner > Data List
Tester Display
|
Measurement Item
|
Range
|
Normal Condition
|
Diagnostic Note
|
Regulator Pressure Sensor
|
Air conditioner pressure sensor
|
Min.: -456.68 kPaG
Max.: 3294.37 kPaG
|
Actual refrigerant pressure displayed
|
-
|
Body Electrical > Air Conditioner > Data List
Tester Display
|
Regulator Pressure Sensor
|
OK:
The voltage and value displayed in the Data List change.
Result
|
Proceed to
|
OK
|
A
|
NG (The voltage changes but the value displayed in the Data List does not change.)
|
NG (The voltage does not change.)
|
B
|
5.
|
CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
|
(a) Disconnect the K55 air conditioning amplifier assembly connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
K55-3 (SG-4) - A18-1 (-)
|
Always
|
Below 1 Ω
|
K55-3 (SG-4) or A18-1 (-) - Other terminals and body ground
|
Always
|
10 kΩ or higher
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
6.
|
CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
|
(a) Disconnect the K55 air conditioning amplifier assembly connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
K55-6 (S5-3) - A18-3 (+)
|
Always
|
Below 1 Ω
|
K55-6 (S5-3) or A18-3 (+) - Other terminals and body ground
|
Always
|
10 kΩ or higher
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
|