Last Modified: 11-20-2023 |
6.11:8.1.0 |
Doc ID: RM1000000013JGQ |
Model Year Start: 2018 |
Model: Camry |
Prod Date Range: [03/2017 - 06/2017] |
Title: HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System): Weak Blower Output; 2018 MY Camry [03/2017 - 06/2017] |
DESCRIPTION
If the airflow from the front registers is weak regardless of the blower speed setting displayed on the air conditioning control panel (radio and display receiver assembly)*1 or air conditioning control assembly*2, the following suspected areas may be the cause.
Symptom
|
Factor
|
-
Airflow volume is constantly low
-
Airflow volume sometimes becomes low
|
-
Communication malfunction between air conditioning amplifier assembly and blower motor with fan sub-assembly
-
Air conditioning amplifier assembly malfunction
-
Blower motor with fan sub-assembly malfunction
-
Clogged clean air filter
-
Clogged No. 1 evaporator sub-assembly or heater radiator unit sub-assembly fins
-
Aspirator not connected properly
|
-
*1: for 8 Inch Display
-
*2: for 7 Inch Display
PROCEDURE
1.
|
CHECK AIR CONDITIONING SYSTEM
|
(a) Operate the blower switch with the following conditions met and check that the airflow volume changes.
Blower Speed
|
Condition
|
LO → HI
|
-
Temperature setting: MAX COLD
-
Air outlet mode: FACE
-
A/C switch: Off
|
OK:
Airflow volume increases.
OK
|
|
|
2.
|
CHECK CLEAN AIR FILTER
|
(a) Visually check the clean air filter.
Click here
OK:
The clean air filter is not dirty or clogged.
OK
|
|
|
3.
|
CHECK NO. 1 COOLER THERMISTOR
|
(a) Check the installation condition of the No. 1 cooler thermistor.
OK:
The No. 1 cooler thermistor is installed correctly.
OK
|
|
|
(a) Check the installation condition of the aspirator.
OK:
The aspirator is installed correctly.
|