Last Modified: 11-20-2023 |
6.11:8.1.0 |
Doc ID: RM1000000013HN4 |
Model Year Start: 2018 |
Model: Camry |
Prod Date Range: [03/2017 -
] |
Title: METER / GAUGE / DISPLAY: METER / GAUGE SYSTEM: Operating Light Control Rheostat does not Change Light Brightness; 2018 - 2024 MY Camry [03/2017 - ] |
Operating Light Control Rheostat does not Change Light Brightness
|
DESCRIPTION
The combination meter assembly receives signals through this circuit to adjust the illumination of the combination meter assembly. The combination meter assembly sets the illumination level based on the user operation of the light control rheostat switch in the trip switch.
WIRING DIAGRAM
CAUTION / NOTICE / HINT
NOTICE:
When replacing the combination meter assembly, always replace it with a new one. If a combination meter assembly which was installed to another vehicle is used, the information stored in it will not match the information from the vehicle and a DTC may be stored.
HINT:
-
The illumination level of the combination meter assembly can be adjusted by pressing the light control rheostat switch (trip switch).
-
The illumination of the combination meter assembly dims when the taillights are turned on.
-
Setting the illumination to maximum brightness cancels the above dimming of the illumination.
PROCEDURE
1.
|
READ VALUE USING TECHSTREAM (LIGHT CONTROL SWITCH (UP) , LIGHT CONTROL SWITCH (DOWN))
|
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Combination Meter / Data List.
(e) Read the Data List according to the display on the Techstream.
Body Electrical > Combination Meter > Data List
Tester Display
|
Measurement Item
|
Range
|
Normal Condition
|
Diagnostic Note
|
Light Control Switch (UP)
|
Light control rheostat up switch (Trip switch)
|
OFF or ON
|
OFF: Switch released
ON: Switch pushed
|
-
|
Light Control Switch (DOWN)
|
Light control rheostat down switch (Trip switch)
|
OFF or ON
|
OFF: Switch released
ON: Switch pushed
|
-
|
Body Electrical > Combination Meter > Data List
Tester Display
|
Light Control Switch (UP)
|
Light Control Switch (DOWN)
|
OK:
Light control rheostat up or down switch condition displayed on the Techstream changes with the actual switch operation.
NG
|
|
|
(a) Remove the trip switch.
Click here
(b) Inspect the trip switch.
Click here
OK
|
|
|
3.
|
CHECK HARNESS AND CONNECTOR (TRIP SWITCH - COMBINATION METER ASSEMBLY)
|
(a) Disconnect the K20 combination meter assembly connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
K111-4 (RV) - K20-2 (TR)
|
Always
|
Below 1 Ω
|
K111-1 (E) - K20-5 (SW3)
|
Always
|
Below 1 Ω
|
K111-4 (RV) or K20-2 (TR) - Body ground
|
Always
|
10 kΩ or higher
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
|