Last Modified: 11-20-2023 |
6.11:8.1.0 |
Doc ID: RM10000000134OH |
Model Year Start: 2018 |
Model: Camry |
Prod Date Range: [03/2017 -
] |
Title: THEFT DETERRENT / KEYLESS ENTRY: THEFT DETERRENT SYSTEM: Ignition Switch Circuit; 2018 - 2024 MY Camry [03/2017 - ] |
DESCRIPTION
The main body ECU (multiplex network body ECU) determines the ignition switch position (LOCK, ACC, ON) based on signals from the IG and ACC circuit.
WIRING DIAGRAM
CAUTION / NOTICE / HINT
NOTICE:
Inspect the fuses for circuits related to this system before performing the following procedure.
PROCEDURE
1.
|
READ VALUE USING TECHSTREAM (ACC SW, IG SW)
|
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Main Body / Data List.
(e) Read the Data List according to the display on the Techstream.
Body Electrical > Main Body > Data List
Tester Display
|
Measurement Item
|
Range
|
Normal Condition
|
Diagnostic Note
|
ACC SW
|
Ignition switch
|
OFF or ON
|
OFF: Ignition switch off
ON: Ignition switch ACC
|
-
|
IG SW
|
Ignition switch
|
OFF or ON
|
OFF: Ignition switch off or ACC
ON: Ignition switch ON
|
-
|
Body Electrical > Main Body > Data List
Tester Display
|
ACC SW
|
IG SW
|
OK:
The Techstream display changes correctly in response to the ignition switch state.
NG
|
|
|
2.
|
INSPECT IGNITION OR STARTER SWITCH ASSEMBLY
|
(a) Remove the ignition or starter switch assembly.
Click here
(b) Inspect the ignition or starter switch assembly.
Click here
OK
|
|
|
3.
|
CHECK HARNESS AND CONNECTOR (BATTERY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
|
(a) Disconnect the 3F instrument panel junction block assembly connector.
(b) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
|
Condition
|
Specified Condition
|
3F-1 - Body ground
|
Always
|
11 to 14 V
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
OK
|
|
|
4.
|
CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - BODY GROUND)
|
(a) Disconnect the 3B instrument panel junction block assembly connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
3B-3 - Body ground
|
Always
|
Below 1 Ω
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
OK
|
|
|
5.
|
CHECK HARNESS AND CONNECTOR (IGNITION OR STARTER SWITCH ASSEMBLY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
|
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
K30-8 (IG1) - 3A-17
|
Always
|
Below 1 Ω
|
K30-8 (IG1) or 3A-17 - Body ground
|
Always
|
10 kΩ or higher
|
K30-6 (ACC) - 3A-30
|
Always
|
Below 1 Ω
|
K30-6 (ACC) or 3A-30 - Other terminals and body ground
|
Always
|
10 kΩ or higher
|
K30-7 (AM1) - 3A-44
|
Always
|
Below 1 Ω
|
K30-7 (AM1) or 3A-44 - Other terminals and body ground
|
Always
|
10 kΩ or higher
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
OK
|
|
|
6.
|
REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
|
(a) Temporarily replace the instrument panel junction block assembly with a new or known good one.
Click here
NEXT
|
|
|
7.
|
CHECK THEFT DETERRENT SYSTEM
|
(a) Check the active arming mode function.
Click here
OK:
The active arming mode function operates normally.
OK |
|
END (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY WAS DEFECTIVE)
|
|