Last Modified: 04-05-2023 |
6.11:8.1.0 |
Doc ID: RM10000000101M8 |
Model Year Start: 2017 |
Model: Sienna |
Prod Date Range: [08/2016 -
] |
Title: UA80F (AUTOMATIC TRANSMISSION / TRANSAXLE): AUTOMATIC TRANSAXLE SYSTEM: P275612,P275614; Torque Converter Clutch Pressure Control Solenoid Control Circuit Short to Battery; 2017 - 2020 MY Sienna [08/2016 - ] |
DTC
|
P275612
|
Torque Converter Clutch Pressure Control Solenoid Control Circuit Short to Battery
|
DTC
|
P275614
|
Torque Converter Clutch Pressure Control Solenoid Control Circuit Short to Ground or Open
|
DESCRIPTION
The ECM controls the shift solenoid valve SLU using a predetermined current, and performs lock-up and flex lock-up control.
DTC No.
|
Detection Item
|
DTC Detection Condition
|
Trouble Area
|
MIL
|
Memory
|
Note
|
P275612
|
Torque Converter Clutch Pressure Control Solenoid Control Circuit Short to Battery
|
1. Diagnosis Condition 2. Malfunction Status 3. Malfunction Time 4. Other
-
Vehicle is being driven
-
Shift solenoid valve SLT circuit is short to +B
-
1 second
-
1-trip detection logic
|
-
Shift solenoid valve SLU
-
Transmission wire
-
Harness and connector
-
ECM
|
Comes on
|
DTC stored
|
SAE Code:
P2763
|
P275614
|
Torque Converter Clutch Pressure Control Solenoid Control Circuit Short to Ground or Open
|
1. Diagnosis Condition 2. Malfunction Status 3. Malfunction Time 4. Other
-
Vehicle is being driven
-
Shift solenoid valve SLT circuit is open or shorted
-
1 second
-
1-trip detection logic
|
-
Shift solenoid valve SLU
-
Transmission wire
-
Harness and connector
-
ECM
|
Comes on
|
DTC stored
|
SAE Code:
P2764
|
MONITOR DESCRIPTION
When an open or short to +B and ground in the shift solenoid valve SLU circuit is detected, the ECM will determine that there is a malfunction, illuminate the MIL and store this DTC.
MONITOR STRATEGY
Related DTCs
|
P2764: Shift solenoid valve SLU/Range check (Low current)
P2763: Shift solenoid valve SLU/Range check (High current)
|
Required sensors/Components
|
Shift solenoid valve SLU
|
Frequency of operation
|
Continuous
|
Duration
|
P2763, P2764: 1 sec.
|
MIL operation
|
Immediate
|
Sequence of operation
|
None
|
TYPICAL ENABLING CONDITIONS
All
Solenoid current cut status
|
Not cut
|
Battery voltage
|
8 V or more
|
Ignition Switch
|
ON
|
Starter
|
OFF
|
P2764
The monitor will run whenever the following DTCs are not present
|
None
|
Battery voltage
|
10.5 V or more
|
Target current
|
0.2 A or more
|
P2763
The monitor will run whenever the following DTCs are not present
|
None
|
Battery voltage
|
10.5 V or more
|
Following condition is met:
|
Condition a. or b.
|
a. Battery voltage
|
8 V or more and less than 12.499 V
|
Target current
|
0.8 A or less
|
b. Battery voltage
|
12.5 V or more and less than 16 V
|
Target current
|
1 A or less
|
TYPICAL MALFUNCTION THRESHOLDS
P2764
Solenoid current
|
Less than 0.075 A
|
P2763
Solenoid current
|
a. or b.
|
a. Battery voltage
|
8 V or more and less than 12.499 V
|
Target current
|
More than 0.92 A
|
b. Battery voltage
|
12.5 V or more and less than 16 V
|
Target current
|
More than 1.1 A
|
COMPONENT OPERATING RANGE
P2764: Solenoid current
|
0.075 A or more
|
P2763: Solenoid current
|
a. or b.
|
a. Battery voltage
|
8 V or more and less than 12.499 V
|
Target current
|
0.92 A or less
|
b. Battery voltage
|
12.5 V or more and less than 16 V
|
Target current
|
1.1 A or less
|
CONFIRMATION DRIVING PATTERN
CAUTION:
When performing the confirmation driving pattern, obey all speed limits and traffic laws.
HINT:
-
After repairs have been completed, clear the DTCs and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
-
When clearing the permanent DTCs, refer to the Clear Permanent DTC procedure.
Click here
-
Connect the Techstream to the DLC3.
-
Turn the ignition switch to ON and turn the Techstream on.
-
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
-
Turn the ignition switch off and wait for 2 minutes or more.
-
Turn the ignition switch to ON and turn the Techstream on.
-
Start the engine.
-
Perform the Lock-up Function inspection in Road Test. [*1]
Click here
HINT:
[*1] : Normal judgment procedure.
The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.
-
Stop the vehicle.
-
Enter the following menus: Powertrain / Transmission / Utility / All Readiness.
-
Input the DTC: P275612 or P275614.
-
Check the DTC judgment result.
Techstream Display
|
Description
|
NORMAL
|
-
DTC judgment completed
-
System normal
|
ABNORMAL
|
-
DTC judgment completed
-
System abnormal
|
INCOMPLETE
|
-
DTC judgment not completed
-
Perform driving pattern after confirming DTC enabling conditions
|
N/A
|
-
Unable to perform DTC judgment
-
Number of DTCs which do not fulfill DTC preconditions has reached ECU memory limit
|
HINT:
-
If the judgment result shows NORMAL, the system is normal.
-
If the judgment result shows ABNORMAL, the system has a malfunction.
-
If the judgment result shows INCOMPLETE or N/A, perform the normal judgment procedure again.
WIRING DIAGRAM
CAUTION / NOTICE / HINT
NOTICE:
-
Perform the universal trip to clear permanent DTCs.
Click here
-
Perform registration and/or initialization when parts related to the automatic transaxle are replaced.
Click here
PROCEDURE
1.
|
CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLU) - ECM)
|
(a) Disconnect the B67 ECM connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
B67-76 (SLU+) - B67-61 (SLU-)
|
20°C (68°F)
|
5.0 to 5.6 Ω
|
B67-76 (SLU+) or B67-61 (SLU-) - Body ground and other terminals
|
Always
|
10 kΩ or higher
|
OK
|
|
|
(a) Replace the ECM.
Click here
3.
|
CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
|
(a) Disconnect the B65 transmission wire connector.
(b) Disconnect the B67 ECM connector.
(c) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
B65-5 (SLU+) - B67-76 (SLU+)
|
Always
|
Below 1 Ω
|
B65-4 (SLU-) - B67-61 (SLU-)
|
Always
|
Below 1 Ω
|
B65-5 (SLU+) or B67-76 (SLU+) - Body ground and other terminals
|
Always
|
10 kΩ or higher
|
B65-4 (SLU-) or B67-61 (SLU-) - Body ground and other terminals
|
Always
|
10 kΩ or higher
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR (TRANSMISSION WIRE - ECM)
|
OK
|
|
|
4.
|
INSPECT SHIFT SOLENOID VALVE SLU
|
(a) Remove the shift solenoid valve SLU.
Click here
|
|
*a
|
Component without harness connected
(Shift Solenoid Valve SLU)
|
|
|
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
Shift solenoid valve SLU connector terminal 1 - terminal 2
|
20°C (68°F)
|
5.0 to 5.6 Ω
|
(c) Connect a positive (+) lead from the battery to terminal 1 and a negative (-) lead with a 21 W bulb to terminal 2 of the solenoid valve connector. Check that the valve moves and makes an operating sound.
OK:
Valve moves and makes operating sound.
|