Last Modified: 04-05-2023 6.11:8.1.0 Doc ID: RM100000000ZPD1
Model Year Start: 2017 Model: Sienna Prod Date Range: [08/2016 -           ]
Title: HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM: DATA LIST / ACTIVE TEST; 2017 - 2020 MY Sienna [08/2016 -        ]

DATA LIST / ACTIVE TEST

1. DATA LIST

Using the Techstream to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

NOTICE:

In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.

(a) Connect the Techstream to the DLC3.

(b) Turn the ignition switch to ON.

(c) Turn the Techstream on.

(d) Enter the following menus: Body Electrical / Air Conditioner / Data List.

(e) Check the value(s) by referring to the table below.

Air Conditioner

Tester Display

Measurement Item/Range

Normal Condition

Diagnostic Note

Room Temperature Sensor

Room temperature sensor /

Min.: -6.5°C (20.3°F)

Max.: 57.25°C (135.05°F)

Actual cabin temperature displayed

-

Ambient Temp Sensor

Ambient temperature sensor /

Min.: -23.3°C (-9.94°F)

Max.: 65.95°C (150.71°F)

Actual ambient temperature displayed

-

Adjusted Ambient Temp

Adjusted ambient temperature /

Min.: -30.8°C (-23.44°F)

Max.: 50.8°C (123.44°F)

-

-

Evaporator Fin Thermistor

Evaporator temperature sensor /

Min.: -29.7°C (-21.46°F)

Max.: 59.55°C (139.19°F)

Actual evaporator temperature displayed

-

Evaporator Target Temp

Evaporator target temperature /

Min.: -327.68°C (-557.82°F)

Max.: 327.67°C (621.81°F)

Evaporator target temperature displayed

-

Solar Sensor (D side)

Driver side solar sensor /

Min.: 0

Max.: 255

Driver side solar sensor value increases as brightness increases

-

Solar Sensor (P side)

Passenger side solar sensor /

Min.: 0

Max.: 255

Passenger side solar sensor value increases as brightness increases

-

Engine Coolant Temp

Engine coolant temperature sensor /

Min.: 1.3°C (34.34°F)

Max.: 90.55°C (194.99°F)

Actual engine coolant temperature displayed

-

Blower Motor Speed Level

Blower motor speed level /

Min.: 0

Max.: 31

Displayed speed level increases in range between 0 and 31 as blower motor speed increases

-

Regulator Pressure Sensor

Air conditioner pressure sensor/

Min.: -66.22 psi (gauge)

Max.: 477.68 psi (gauge)

Actual regulator pressure displayed

-

Regulator Control Current

Regulator control current /

Min.: 0 A

Max.: 0.997 A

Value changes between 0 A and 0.997 A in accordance with compressor and magnetic clutch operation

-

Room Temp Sensor (Rear)

Room temperature sensor /

Min.: -6.5°C (20.3°F)

Max.: 57.25°C (135.05°F)

Actual room temperature for front seat is displayed

Open in the circuit: -6.5°C (20.3°F)

Short in the circuit: 57.25°C (135.05°F)

Evap Temp Sens (Rear)

Rear evaporator temperature sensor /

Min.: -29.7°C (-21.46°F)

Max.: 59.55°C (139.19°F)

Actual rear evaporator temperature is displayed

Open in the circuit: -29.7°C (-21.46°F)

Short in the circuit: 59.55°C (139.19°F)

Blower Motor Level (Rear)

Blower motor speed level /

Min.: 0

Max.: 31

Increases in range between 0 and 31 as blower motor speed increases

-

Air Outlet Servo Pulse (R)

Rear air outlet servo motor target pulse /

Min.: 128

Max.: 383

FACE: 211 (pulse)

B/L: 163 (pulse)

FOOT: 135 (pulse)

-

Air Outlet Servo Actual Pls(R)

Rear air outlet servo motor actual pulse /

Min.: 128

Max.: 383

FACE: 211 (pulse)

B/L: 163 (pulse)

FOOT: 135 (pulse)

-

Air Mix Servo Targ Pulse(R)

Rear air mix servo motor target pulse /

Min.: 128

Max.: 383

MAX. COLD: 137 (pulse)

MAX. HOT: 182 (pulse)

-

Air Mix Servo Actual Pulse(R)

Rear air mix servo motor actual pulse /

Min.: 128

Max.: 383

MAX. COLD: 137 (pulse)

MAX. HOT: 182 (pulse)

-

Air Mix Servo Targ Pulse(D)

Driver side air mix servo motor target pulse /

Min.: 128

Max.: 383

MAX. COLD: 133 (pulse)

MAX. HOT: 231 (pulse)

-

Air Mix Servo Actual Pulse(D)

Driver side air mix servo motor actual pulse /

Min.: 128

Max.: 383

MAX. COLD: 133 (pulse)

MAX. HOT: 231 (pulse)

-

Air Mix Servo Targ Pulse(P)

Passenger side air mix servo motor target pulse /

Min.: 128

Max.: 383

MAX. COLD: 233 (pulse)

MAX. HOT: 135 (pulse)

-

Air Mix Servo Actual Pulse(P)

Passenger side air mix servo motor actual pulse /

Min.: 128

Max.: 383

MAX. COLD: 233 (pulse)

MAX. HOT: 135 (pulse)

-

Air Outlet Servo Pulse (D)

Air outlet servo motor target pulse /

Min.: 128

Max.: 383

FACE: 136 (pulse)

B/L: 158 to 166 (pulse)

FOOT: 178 to 202 (pulse)

FOOT/DEF: 208 (pulse)

DEF: 225 (pulse)

-

Air Outlet Servo Actu Pulse(D)

Air outlet servo motor actual pulse /

Min.: 128

Max.: 383

FACE: 136 (pulse)

B/L: 158 to 166 (pulse)

FOOT: 178 to 202 (pulse)

FOOT/DEF: 208 (pulse)

DEF: 225 (pulse)

-

Air Inlet Damper Targ Pulse

Air inlet servo motor target pulse /

Min.: 128

Max.: 383

RECIRCULATION: 135 (pulse)

FRESH: 156 (pulse)

-

Air Inlet Damper Actual Pulse

Air inlet servo motor actual pulse /

Min.: 128

Max.: 383

RECIRCULATION: 135 (pulse)

FRESH: 156 (pulse)

-

Electric Heater Count

Maximum heater operation level /

Min.: 0

Max.: 3

Maximum possible operation level of quick heater assembly (PTC heater) displayed

-

Electric Heater Active Level

Actual heater operation level /

Min.: 0

Max.: 3

Actual operation level of quick heater assembly (PTC heater) displayed

-

Shift Set Temperature

Shift set temperature / 2C decr, 1C decr, Normal, 1C incr, 2C incr

Customized value will be displayed

-

Compressor Mode

Compressor mode / Auto, Manual

Customized value will be displayed

-

Evaporator Control

Evaporator control / Auto, Manual

Customized value will be displayed

-

Refrigerant Shortage Check

Refrigerant shortage check / ON, OFF

Customized value displayed

-

Fan speed increment control

Fan speed increment control / Slow, Normal, Fast

Customized value displayed

-

Foot/DEF Auto Mode

FOOT/DEF auto mode / ON, OFF

Customized value will be displayed

-

Foot/DEF Auto Blow Up

FOOT/DEF auto blower up function / ON, OFF

Customized value will be displayed

-

A/C Cutoff Signal

A/C Cutoff Signal / ON, OFF

ON: A/C cutoff signal ON

OFF: A/C cutoff signal OFF

-

Refrigerant Gas Type

Refrigerant gas type / R134a or 1234yf

Refrigerant gas type displayed

-

Set Temperature (D side)

Driver side set temperature /

Min.: MAX COLD

Max.: MAX HOT

Driver side actual set temperature displayed

-

Set Temperature (P side)

Passenger side set temperature /

Min.: MAX COLD

Max.: MAX HOT

Passenger side actual set temperature displayed

-

Set Temperature (Rear)

Rear side set temperature /

Min.: MAX COLD

Max.: MAX HOT

Rear side actual set temperature is displayed

-

Outside Air Mode Auto Switch Function

Outside air mode auto switch function / ON, OFF

Customized value displayed

-

Number of Trouble Codes

Number of trouble codes /

Min.: 0

Max.: 255

Number of DTCs displayed

-

Engine

Tester Display

Measurement Item/Range

Normal Condition

Diagnostic Note

A/C Signal

A/C Signal / ON, OFF

ON: A/C ON

OFF: A/C OFF

-

2. ACTIVE TEST

Using the Techstream to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.

(a) Connect the Techstream to the DLC3.

(b) Turn the ignition switch to ON.

(c) Turn the Techstream on.

(d) Enter the following menus: Body Electrical / Air Conditioner / Active Test.

(e) Check the operation by referring to the table below.

Air Conditioner

Tester Display

Measurement Item

Control Range

Diagnostic Note

Blower Motor

Blower motor with fan sub-assembly

Min.: 0

Max.: 31

-

Magnetic Clutch Relay

Air conditioning system operation

OFF or ON

-

Defogger Relay (Rear)

Rear window defogger operation

OFF or ON

-

Mirror Heater Relay

Mirror heater operation

OFF or ON

-

Heater Active Level

Quick heater assembly

Min.: 0

Max.: 3

-

Air Mix Servo Targ Pulse (D)

Air mix control servo motor (for driver side) target pulse

Min.: 128

Max.: 383

-

Air Mix Servo Targ Pulse (P)

Air mix control servo motor (for front passenger side) target pulse

Min.: 128

Max.: 383

-

Air Outlet Servo Pulse (D)

Air outlet control servo motor pulse

Min.: 128

Max.: 383

-

Air Inlet Damper Targ Pulse

Air inlet control servo motor target pulse

Min.: 128

Max.: 383

-

Blower Motor Level (Rear)

Rear blower motor

Min.: 0

Max.: 31

-

Rear Air Mix Servo Targ Pulse

Rear air mix control servo motor target pulse

Min.: 128

Max.: 383

-

A/O Servo Pulse (Rr D)

Rear air outlet control servo motor sub-assembly pulse

Min.: 128

Max.: 383

-