Last Modified: 04-05-2023 6.11:8.1.0 Doc ID: RM100000000Z9IR
Model Year Start: 2017 Model: Sienna Prod Date Range: [08/2016 -           ]
Title: 2GR-FKS (ENGINE CONTROL): CAMSHAFT OIL CONTROL VALVE(for Bank 1): ON-VEHICLE INSPECTION; 2017 - 2020 MY Sienna [08/2016 -        ]

ON-VEHICLE INSPECTION

PROCEDURE

1. REMOVE CAMSHAFT TIMING OIL CONTROL SOLENOID ASSEMBLY

Click here 2017 - 2020 MY Sienna [08/2016 -        ]; 2GR-FKS (ENGINE CONTROL): CAMSHAFT OIL CONTROL SOLENOID(for Bank 1): REMOVAL

2. INSPECT CAMSHAFT TIMING GEAR BOLT

(a) for intake side:

(1) Check the stroke of the plunger in the center of the camshaft timing gear bolt.

Standard Stroke:

4.5 mm (0.177 in.) or more

HINT:

When pressing the plunger, there may be a stepped feeling. This is not a malfunction.

If the result is not as specified, replace the camshaft timing gear bolt.

*a

Plunger

(b) for exhaust side:

(1) Check the stroke of the plunger in the center of the camshaft timing gear bolt.

Standard Stroke:

2.2 mm (0.0866 in.) or more

HINT:

When pressing the plunger, there may be a stepped feeling. This is not a malfunction.

If the result is not as specified, replace the camshaft timing gear bolt.

*a

Plunger

3. INSTALL CAMSHAFT TIMING OIL CONTROL SOLENOID ASSEMBLY

Click here 2017 - 2020 MY Sienna [08/2016 -        ]; 2GR-FKS (ENGINE CONTROL): CAMSHAFT OIL CONTROL SOLENOID(for Bank 1): INSTALLATION