Last Modified: 04-05-2023 |
6.11:8.1.0 |
Doc ID: RM100000000YZIZ |
Model Year Start: 2017 |
Model: Sienna |
Prod Date Range: [08/2016 -
] |
Title: UA80E (AUTOMATIC TRANSMISSION / TRANSAXLE): PARK / NEUTRAL POSITION SWITCH: ADJUSTMENT; 2017 - 2020 MY Sienna [08/2016 - ] |
ADJUSTMENT
PROCEDURE
1. PRECAUTION
NOTICE:
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notices before proceeding with work.
Click here
2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
NOTICE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected.
Click here
3. REMOVE BATTERY
Click here
4. REMOVE AIR CLEANER INLET ASSEMBLY
Click here
5. REMOVE AIR CLEANER CAP WITH AIR CLEANER HOSE
Click here
6. REMOVE AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY
Click here
7. REMOVE AIR CLEANER CASE SUB-ASSEMBLY
Click here
8. DISCONNECT TRANSMISSION CONTROL CABLE ASSEMBLY
Click here
9. ADJUST PARK/NEUTRAL POSITION SWITCH
(a) Disconnect the park/neutral position switch connector.
|
|
(b) Remove the nut and transmission control shaft lever from the manual valve lever shaft sub-assembly.
(c) Loosen the 2 bolts of the park/neutral position switch.
|
|
(d) Align the protrusion with the neutral basic line.
|
|
*a
|
Neutral Basic Line
|
*b
|
Protrusion
|
|
|
(e) Hold the park/neutral position switch in position and tighten the 2 bolts.
Torque:
5.4 N·m {55 kgf·cm, 48 in·lbf}
(f) Install the transmission control shaft lever to the manual valve lever shaft sub-assembly with the nut.
Torque:
12.7 N·m {130 kgf·cm, 9 ft·lbf}
(g) Connect the park/neutral position switch connector.
10. CONNECT TRANSMISSION CONTROL CABLE ASSEMBLY
Click here
11. INSPECT PARK/NEUTRAL POSITION SWITCH OPERATION
Click here
12. INSTALL AIR CLEANER CASE SUB-ASSEMBLY
Click here
13. INSTALL AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY
Click here
14. INSTALL AIR CLEANER CAP WITH AIR CLEANER HOSE
Click here
15. INSTALL AIR CLEANER INLET ASSEMBLY
Click here
16. INSTALL BATTERY
Click here
17. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
Torque:
5.4 N·m {55 kgf·cm, 48 in·lbf}
NOTICE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected.
Click here
|