Last Modified: 04-05-2023 |
6.11:8.1.0 |
Doc ID: RM100000000YSP6 |
Model Year Start: 2017 |
Model: Sienna |
Prod Date Range: [08/2016 - 11/2017] |
Title: 2GR-FKS (ENGINE CONTROL): SFI SYSTEM: P003612,P003614,P005612,P005614,P014118,P016118,P102A9E,P105A9E; HO2S Heater Control Circuit Bank 1 Sensor 2 Circuit Short to Battery; 2017 MY Sienna [08/2016 - 11/2017] |
DTC
|
P003612
|
HO2S Heater Control Circuit Bank 1 Sensor 2 Circuit Short to Battery
|
DTC
|
P003614
|
HO2S Heater Control Circuit Bank 1 Sensor 2 Circuit Short to Ground or Open
|
DTC
|
P005612
|
HO2S Heater Control Bank 2 Sensor 2 Circuit Short to Battery
|
DTC
|
P005614
|
HO2S Heater Control Bank 2 Sensor 2 Circuit Short to Ground or Open
|
DTC
|
P014118
|
O2 Sensor Heater Circuit Bank 1 Sensor 2 Circuit Current Below Threshold
|
DTC
|
P016118
|
O2 Sensor Heater Circuit Bank 2 Sensor 2 Circuit Current Below
|
DTC
|
P102A9E
|
O2 Sensor Heater Performance Bank 1 Sensor 2 Stuck On
|
DTC
|
P105A9E
|
O2 Sensor Heater Performance Bank 2 Sensor 2 Stuck On
|
DESCRIPTION
Refer to DTC P013611.
Click here
HINT:
-
When any of these DTCs are stored, the ECM enters fail-safe mode. The ECM turns off the heated oxygen sensor heater in fail-safe mode. Fail-safe mode continues until the ignition switch is turned off.
-
The heated oxygen sensor heater circuit uses a relay on the +B side of the circuit.
DTC No.
|
Detection Item
|
DTC Detection Condition
|
Trouble Area
|
MIL
|
Memory
|
Note
|
P003612
|
HO2S Heater Control Circuit Bank 1 Sensor 2 Circuit Short to Battery
|
Heated oxygen sensor heater current reaches high limit (1 trip detection logic).
|
-
Short in heated oxygen sensor (bank 1 sensor 2) heater circuit
-
Heated oxygen sensor (bank 1 sensor 2)
-
ECM
|
Comes on
|
DTC stored
|
-
SAE Code: P0038
-
DTC for Mexico Models: Applies
|
P003614
|
HO2S Heater Control Circuit Bank 1 Sensor 2 Circuit Short to Ground or Open
|
Heated oxygen sensor heater current is the specified value or less while the heater is operating (1 trip detection logic).
|
-
Open or short in heated oxygen sensor (bank 1 sensor 2) heater circuit
-
Heated oxygen sensor (bank 1 sensor 2)
-
Semiconductor pwr integration ECU
-
ECM
|
Comes on
|
DTC stored
|
-
SAE Code: P0037
-
DTC for Mexico Models: Applies
|
P005612
|
HO2S Heater Control Bank 2 Sensor 2 Circuit Short to Battery
|
Heated oxygen sensor heater current reaches high limit (1 trip detection logic).
|
-
Short in heated oxygen sensor (bank 2 sensor 2) heater circuit
-
Heated oxygen sensor (bank 2 sensor 2)
-
ECM
|
Comes on
|
DTC stored
|
-
SAE Code: P0058
-
DTC for Mexico Models: Applies
|
P005614
|
HO2S Heater Control Bank 2 Sensor 2 Circuit Short to Ground or Open
|
Heated oxygen sensor heater current is the specified value or less while the heater is operating (1 trip detection logic).
|
-
Open or short in heated oxygen sensor (bank 2 sensor 2) heater circuit
-
Heated oxygen sensor (bank 2 sensor 2)
-
Semiconductor pwr integration ECU
-
ECM
|
Comes on
|
DTC stored
|
-
SAE Code: P0057
-
DTC for Mexico Models: Applies
|
P014118
|
O2 Sensor Heater Circuit Bank 1 Sensor 2 Circuit Current Below Threshold
|
The cumulative heater resistance correction value exceeds the threshold (2 trip detection logic).
|
-
Open or short in heated oxygen sensor (bank 1 sensor 2) heater circuit
-
Heated oxygen sensor (bank 1 sensor 2)
-
Semiconductor pwr integration ECU
-
ECM
|
Comes on
|
DTC stored
|
-
SAE Code: P0141
-
DTC for Mexico Models: Does not apply
|
P016118
|
O2 Sensor Heater Circuit Bank 2 Sensor 2 Circuit Current Below
|
The cumulative heater resistance correction value exceeds the threshold (2 trip detection logic).
|
-
Open or short in heated oxygen sensor (bank 2 sensor 2) heater circuit
-
Heated oxygen sensor (bank 2 sensor 2)
-
Semiconductor pwr integration ECU
-
ECM
|
Comes on
|
DTC stored
|
-
SAE Code: P0161
-
DTC for Mexico Models: Does not apply
|
P102A9E
|
O2 Sensor Heater Performance Bank 1 Sensor 2 Stuck On
|
Heated oxygen sensor heater current is higher than the specified value while the heater is not operating (1 trip detection logic).
|
-
Short in heated oxygen sensor (bank 1 sensor 2) heater circuit
-
Heated oxygen sensor (bank 1 sensor 2)
-
ECM
|
Comes on
|
DTC stored
|
-
SAE Code: P102D
-
DTC for Mexico Models: Applies
|
P105A9E
|
O2 Sensor Heater Performance Bank 2 Sensor 2 Stuck On
|
Heated oxygen sensor heater current is higher than the specified value while the heater is not operating (1 trip detection logic).
|
-
Short in heated oxygen sensor (bank 2 sensor 2) heater circuit
-
Heated oxygen sensor (bank 2 sensor 2)
-
ECM
|
Comes on
|
DTC stored
|
-
SAE Code: P105D
-
DTC for Mexico Models: Applies
|
MONITOR DESCRIPTION
The sensing portion of the heated oxygen sensor has a zirconia element which is used to detect the oxygen concentration in the exhaust gas. If the zirconia element is at the appropriate temperature, and the difference between the oxygen concentrations surrounding the inside and outside surfaces of the sensor is large, the zirconia element generates voltage signals. In order to increase the oxygen concentration detecting capacity of the zirconia element, the ECM supplements the heat from the exhaust with heat from a heating element inside the sensor.
Heated Oxygen Sensor Heater Range Check (P003612, P003614, P005612, P005614, P102A9E and P105A9E):
-
The ECM monitors the current applied to the heated oxygen sensor heater to check the heater for malfunctions.
If the heater current is outside the normal range, the signal transmitted by the heated oxygen sensor becomes inaccurate. When the current in the heated oxygen sensor heater is outside the normal operating range, the ECM interprets this as a malfunction in the sensor heater and stores a DTC.
Heated Oxygen Sensor Heater Performance (P014118 and P016118):
-
After the accumulated heater on time exceeds 100 seconds, the ECM calculates the heater resistance using battery voltage and the current applied to the heater. If the resistance is above the threshold value, the ECM determines that there is a malfunction in the heated oxygen sensor heater and stores DTC P014118 and P016118.
MONITOR STRATEGY
Related DTCs
|
P0037: Heated oxygen sensor (bank 1 sensor 2) heater range check (low current)
P0038: Heated oxygen sensor (bank 1 sensor 2) heater range check (high current)
P0057: Heated oxygen sensor (bank 2 sensor 2) heater range check (low current)
P0058: Heated oxygen sensor (bank 2 sensor 2) heater range check (high current)
P0141: Heated oxygen sensor (bank 1 sensor 2) heater performance
P0161: Heated oxygen sensor (bank 2 sensor 2) heater performance
P102D: Heated oxygen sensor (bank 1 sensor 2) heater performance
P105D: Heated oxygen sensor (bank 2 sensor 2) heater performance
|
Required Sensors/Components (Main)
|
Heated oxygen sensor (sensor 2) heater
|
Required Sensors/Components (Related)
|
-
|
Frequency of Operation
|
Continuous: P0037, P0038, P0056, P0058, P102D, P105D
Once per driving cycle: P0141, P0161
|
Duration
|
0.5 seconds: P0037, P0057, P102D, P105D
2.064 seconds: P0038, P0058
10 seconds: P0141, P0161
|
MIL Operation
|
Immediate: P0037, P0038, P0056, P0058, P102D, P105D
2 driving cycles: P0141, P0161
|
Sequence of Operation
|
None
|
TYPICAL ENABLING CONDITIONS
All
Monitor runs whenever the following DTCs are not stored
|
None
|
P0037 and P0057: (Case 1)
All of the following conditions are met
|
-
|
Battery voltage
|
10.5 V or higher
|
Engine
|
Running
|
Starter
|
Off
|
Catalyst active air fuel ratio control
|
Not operating
|
Time after heater on
|
10 seconds or more
|
Learned heater off current operation
|
Completed
|
Learned heater off current operation
|
Succeeded
|
Heated oxygen sensor heater high current fail (P0038, P0058)
|
Not detected
|
Heater on current - Learned heater off current
|
0.15 A or less
|
Command to heater output
|
On
|
P0037 and P0057: (Case 2)
All of the following conditions are met
|
-
|
Battery voltage
|
10.5 V or higher
|
Engine
|
Running
|
Starter
|
Off
|
Catalyst active air fuel ratio control
|
Not operating
|
Time after heater on
|
10 seconds or more
|
Learned heater off current operation
|
Completed
|
Heated oxygen sensor heater high current fail (P0038, P0058)
|
Not detected
|
Heater off current
|
Higher than 3.5 A
|
Heater current detected by heater monitor IC
|
4 A or higher
|
P0038 and P0058
All of the following conditions are met
|
-
|
Battery voltage
|
10.5 V or higher
|
Engine
|
Running
|
Starter
|
Off
|
Catalyst active air fuel ratio control
|
Not operating
|
Time after heater on
|
10 seconds or more
|
Learned heater off current operation
|
Completed
|
P0141 and P0161
All of the following conditions are met
|
-
|
Heated oxygen sensor heater circuit fail (P0037, P0038, P0057, P0058, P102D and P105D)
|
Not detected
|
Battery voltage
|
10.5 V or higher
|
Fuel cut
|
Off
|
Time after fuel cut on to off
|
30 seconds or more
|
Accumulated heater on time
|
100 seconds or more
|
Learned heater off current operation
|
Completed
|
Duration that heated oxygen sensor impedance is less than 15 kΩ
|
2 seconds or more
|
P102D and P105D
All of the following conditions are met
|
-
|
Battery voltage
|
10.5 V or higher
|
Engine
|
Running
|
Starter
|
Off
|
Catalyst active air fuel ratio control
|
Not operating
|
Time after heater on
|
10 seconds or more
|
Learned heater off current operation
|
Completed
|
Heated oxygen sensor heater low current fail (P0037, P0057)
|
Not detected
|
Heated oxygen sensor heater high current fail (P0038, P0058)
|
Not detected
|
TYPICAL MALFUNCTION THRESHOLDS
P0037 and P0057: (Case 1)
Heater on current - Learned heater off current
|
0.15 A or less
|
P0037 and P0057: (Case 2)
Heater on current
|
1 A or less
|
P0038 and P0058
Both of the following conditions are met
|
-
|
Heater current detected by heater monitor IC
|
4 A or higher
|
Command to heater output
|
On
|
P0141 and P0161
Heater resistance
|
Varies with sensor element temperature (Example: Higher than 23 Ω)
|
P102D and P0105D
Heater on current
|
Higher than 1 A
|
MONITOR RESULT
Refer to detailed information in Checking Monitor Status.
Click here
P0141: O2 Sensor Heater / O2 HEATER B1S2
Monitor ID
|
Test ID
|
Scaling
|
Unit
|
Description
|
$42
|
$91
|
Multiply by 0.001
|
Ohm
|
Oxygen sensor heater resistance bank 1 sensor 2
|
P0161: O2 Sensor Heater / O2 HEATER B2S2
Monitor ID
|
Test ID
|
Scaling
|
Unit
|
Description
|
$46
|
$91
|
Multiply by 0.001
|
Ohm
|
Oxygen sensor heater resistance bank 2 sensor 2
|
CONFIRMATION DRIVING PATTERN
HINT:
-
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click here
-
When clearing the permanent DTCs, refer to the "CLEAR PERMANENT DTC" procedure.
Click here
-
Connect the Techstream to the DLC3.
-
Turn the ignition switch to ON and turn the Techstream on.
-
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
-
Turn the ignition switch off and wait for at least 30 seconds.
-
Turn the ignition switch to ON and turn the Techstream on [A].
-
Start the engine and idle it for 5 minutes or more [B].
-
With the vehicle stationary, depress the accelerator pedal and maintain an engine speed of 3000 rpm for 1 minute [C].
-
Idle the engine for 5 minutes or more [D].
-
Enter the following menus: Powertrain / Engine / Trouble Codes [E].
-
Read the pending DTCs.
HINT:
-
If a pending DTC is output, the system is malfunctioning.
-
If a pending DTC is not output, perform the following procedure.
-
Enter the following menus: Powertrain / Engine / Utility / All Readiness.
-
Input the DTC: P003612, P003614, P005612, P005614, P014118, P016118, P102A9E or P105A9E.
-
Check the DTC judgment result.
Techstream Display
|
Description
|
NORMAL
|
-
DTC judgment completed
-
System normal
|
ABNORMAL
|
-
DTC judgment completed
-
System abnormal
|
INCOMPLETE
|
-
DTC judgment not completed
-
Perform driving pattern after confirming DTC enabling conditions
|
WIRING DIAGRAM
Refer to DTC P013611.
Click here
CAUTION / NOTICE / HINT
NOTICE:
Inspect the fuses for circuits related to this system before performing the following procedure.
PROCEDURE
1.
|
INSPECT HEATED OXYGEN SENSOR (HEATER RESISTANCE)
|
(a) Inspect the heated oxygen sensor.
Click here
HINT:
Perform "Inspection After Repair" after replacing the heated oxygen sensor.
Click here
OK
|
|
|
2.
|
CHECK TERMINAL VOLTAGE (POWER SOURCE OF HEATED OXYGEN SENSOR)
|
*a
|
Front view of wire harness connector
(to Heated Oxygen Sensor)
|
*b
|
Bank 1
|
*c
|
Bank 2
|
(a) Disconnect the heated oxygen sensor connector.
(b) Turn the ignition switch to ON.
(c) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
|
Switch Condition
|
Specified Condition
|
D38-2 (+B) - Body ground
|
Ignition switch ON
|
11 to 14 V
|
B33-2 (+B) - Body ground
|
Ignition switch ON
|
11 to 14 V
|
OK
|
|
|
3.
|
CHECK HARNESS AND CONNECTOR (HEATED OXYGEN SENSOR - ECM)
|
(a) Disconnect the D38 and B33 heated oxygen sensor connectors.
(b) Disconnect the B67 ECM connector.
(c) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
D38-1 (HT1B) - B67-50 (HT1B)
|
Always
|
Below 1 Ω
|
B33-1 (HT2B) - B67-16 (HT2B)
|
Always
|
Below 1 Ω
|
D38-1 (HT1B) or B67-50 (HT1B) - Body ground and other terminals
|
Always
|
10 kΩ or higher
|
B33-1 (HT2B) or B67-16 (HT2B) - Body ground and other terminals
|
Always
|
10 kΩ or higher
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
OK
|
|
|
4.
|
CHECK WHETHER DTC OUTPUT RECURS (DTC P003612, P003614, P005612, P005614, P014118, P016118, P102A9E OR P105A9E)
|
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Turn the Techstream on.
(d) Clear the DTCs.
(e) Turn the ignition switch off and wait for at least 30 seconds.
(f) Turn the ignition switch to ON.
(g) Turn the Techstream on.
(h) Drive the vehicle in accordance with the driving pattern described in Confirmation Driving Pattern.
(i) Enter the following menus: Powertrain / Engine / Trouble Codes.
(j) Read the DTCs.
Result
|
Proceed to
|
DTCs are not output
|
A
|
DTC P003612, P003614, P005612, P005614, P014118, P016118, P102A9E or P105A9E is output
|
B
|
5.
|
INSPECT EFI MAIN RELAY
|
(a) Inspect the EFI MAIN relay.
Click here
NG |
|
REPLACE EFI MAIN RELAY
|
OK
|
|
|
6.
|
CHECK HARNESS AND CONNECTOR (HEATED OXYGEN SENSOR - EFI MAIN RELAY)
|
(a) Disconnect the D38 and B33 heated oxygen sensor connectors.
(b) Remove the EFI MAIN relay from the engine room relay block.
(c) Remove the EFI-MAIN No. 2 relay from the engine room relay block.
HINT:
Remove the EFI-MAIN NO. 2 relay connected between the checked terminals as the coil inside the relay influences the measurement value.
(d) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
D38-2 (+B) - 3 (EFI MAIN relay holder)
|
Always
|
Below 1 Ω
|
B33-2 (+B) - 3 (EFI MAIN relay holder)
|
Always
|
Below 1 Ω
|
D38-2 (+B) or 3 (EFI MAIN relay holder) - Body ground and other terminals
|
Always
|
10 kΩ or higher
|
B33-2 (+B) or 3 (EFI MAIN relay holder) - Body ground and other terminals
|
Always
|
10 kΩ or higher
|
NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
|
|