Last Modified: 04-05-2023 6.11:8.1.0 Doc ID: RM100000000YQVR
Model Year Start: 2017 Model: Sienna Prod Date Range: [08/2016 -           ]
Title: 2GR-FKS EMISSION CONTROL: PURGE VALVE: INSPECTION; 2017 - 2020 MY Sienna [08/2016 -        ]

INSPECTION

PROCEDURE

1. INSPECT PURGE VALVE (PURGE VSV)

(a) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

1 - 2

20°C (68°F)

23 to 26 Ω

If the result is not as specified, replace the purge valve (purge VSV).

(b) Apply battery voltage between the terminals of the purge valve (purge VSV) and check that the following occurs when blowing air into the port (E).

OK:

Measurement Condition

Specified Condition

Battery voltage applied between terminals 1 and 2

Air flows from port (F)

Battery voltage not applied between terminals 1 and 2

Air does not flow

If the result is not as specified, replace the purge valve (purge VSV).

*a

Port (E)

*b

Port (F)

*c

Air

*d

Component without harness connected

(Purge Valve (Purge VSV))