Last Modified: 04-05-2023 6.11:8.1.0 Doc ID: RM100000000VK61
Model Year Start: 2016 Model: Sienna Prod Date Range: [12/2015 -           ]
Title: WINDOW / GLASS: POWER WINDOW CONTROL SYSTEM: FAIL-SAFE CHART; 2016 - 2020 MY Sienna [12/2015 -        ]

FAIL-SAFE CHART

1. PULSE FAILURE

(a) If the pulse sensor malfunctions, the following power window operations are prohibited.

Multiplex Network Master Switch Assembly, Front Power Window Regulator Switch Assembly LH, Rear Power Window Regulator Switch Assembly LH/RH

Power Window Operation

Condition

Ignition switch ON

Ignition switch off

(Key-off operation permitted)

Ignition switch off

(Key-off operation prohibited)

Manual up (Switch on the door)

X

-

Manual down (Switch on the door)

X

-

Auto up (Switch on the door)

X

X

-

Auto down (Switch on the door)

X

X

-

Manual up (Remote switch operation)

X

X

-

Manual down (Remote switch operation)

X

X

-

Auto up (Remote switch operation)

X

X

-

Auto down (Remote switch operation)

X

X

-

HINT:

  • ●: Operates without jam protection/catch protection
  • ▲: Inching operates for approximately 0.4 seconds without jam protection/catch protection
  • X: Operation prohibited

Fail-safe deactivation condition

  • When the pulse sensor is normal, to deactivate fail-safe mode, pull up the power window switch to the auto up position and hold it for at least 1 second to fully close the window from the fully open position. As a result, the auto up/down function will return.

2. DISPLACEMENT OF NON-DETECTION RANGE TO THE OPENING DIRECTION

(a) If the window position or learned value is abnormal, the following power window operations are prohibited.

Multiplex Network Master Switch Assembly, Front Power Window Regulator Switch Assembly LH, Rear Power Window Regulator Switch Assembly LH/RH

Power Window Operation

Condition

Ignition switch ON

Ignition switch off

(Key-off operation permitted)

Ignition switch off

(Key-off operation prohibited)

Manual up (Switch on the door)

X

-

Manual down (Switch on the door)

X

-

Auto up (Switch on the door)

X

X

-

Auto down (Switch on the door)

X

X

-

Manual up (Remote switch operation)

X

X

-

Manual down (Remote switch operation)

X

X

-

Auto up (Remote switch operation)

X

X

-

Auto down (Remote switch operation)

X

X

-

HINT:

  • ●: Operates without jam protection/catch protection
  • X: Operation prohibited

Fail-safe deactivation condition

  • When the pulse sensor is normal, to deactivate fail-safe mode, pull up the power window switch to the auto up position and hold it for at least 1 second to fully close the window from the fully open position. As a result, the auto up/down function will return.

3. INITIALIZATION FAILURE

(a) During initialization, when the window position or initialization complete status cannot be properly read from the non-volatile memory, the following power window operations are prohibited.

Multiplex Network Master Switch Assembly, Front Power Window Regulator Switch Assembly LH, Rear Power Window Regulator Switch Assembly LH/RH

Power Window Operation

Condition

Ignition switch ON

Ignition switch off

(Key-off operation permitted)

Ignition switch off

(Key-off operation prohibited)

Manual up (Switch on the door)

X

-

Manual down (Switch on the door)

X

-

Auto up (Switch on the door)

X

X

-

Auto down (Switch on the door)

X

X

-

Manual up (Remote switch operation)

X

X

-

Manual down (Remote switch operation)

X

X

-

Auto up (Remote switch operation)

X

X

-

Auto down (Remote switch operation)

X

X

-

HINT:

  • ●: Operates without jam protection/catch protection
  • X: Operation prohibited

Fail-safe deactivation condition

  • Perform initialization (See page 2016 - 2020 MY Sienna [12/2015 -        ]; WINDOW / GLASS: POWER WINDOW CONTROL SYSTEM: INITIALIZATION ).

4. LIN COMMUNICATION FAILURE

(a) If the LIN communication line is malfunctioning (communication stop), the power window control system prohibits operation as follows. (Operation is only possible using the power window switch of each seat.)

Multiplex Network Master Switch Assembly

Power Window Operation

Condition

Always

Manual up

●*

Manual down

Auto up

-

Auto down

-

Front Power Window Regulator Switch Assembly LH, Rear Power Window Regulator Switch Assembly LH/RH

Power Window Operation

Condition

Always

Manual up

●*

Manual down

Auto up

●*

Auto down

HINT:

  • ●: Operates without jam protection/catch protection
  • X: Operation prohibited
  • *: Jam protection/catch protection operates.

Fail-safe deactivation condition

  • Check LIN communication system (See page 2016 - 2020 MY Sienna [12/2015 -        ]; NETWORKING: LIN COMMUNICATION SYSTEM: HOW TO PROCEED WITH TROUBLESHOOTING ).

5. PULSE FAILURE AND LIN COMMUNICATION FAILURE

(a) If the LIN communication line is malfunctioning (communication stop) and the pulse sensor is malfunctioning, the following power window operations are prohibited.

Front Power Window Regulator Switch Assembly LH, Rear Power Window Regulator Switch Assembly LH/RH

Power Window Operation

Condition

Always

Manual up

X

Manual down

X

Auto up

X

Auto down

X

HINT:

  • ●: Operates without jam protection/catch protection
  • X: Operation prohibited
  • Switch on the door:

    When the jam protection function does not operate due to the LIN communication failure, the manual up and auto up functions will not operate, as the state of the IG signal is unknown.

  • Remote switch operation:

    Operation is not possible during the LIN communication failure.

6. DISPLACEMENT OF NON-DETECTION RANGE TO THE OPENING DIRECTION AND LIN COMMUNICATION FAILURE / INITIAL FAILURE AND LIN COMMUNICATION FAILURE

(a) If the LIN communication line is malfunctioning and the window position and learned value are abnormal, or the LIN communication line is malfunctioning and the window position or initialization complete status cannot be properly read from the non-volatile memory during initialization, the following power window operations are prohibited.

Multiplex Network Master Switch Assembly

Power Window Operation

Condition

Always

Manual up

●*

Manual down

Auto up

-

Auto down

-

Front Power Window Regulator Switch Assembly LH, Rear Power Window Regulator Switch Assembly LH/RH

Power Window Operation

Condition

Always

Manual up

●*

Manual down

Auto up

X

Auto down

X

HINT:

  • ●: Operates without jam protection/catch protection
  • X: Operation prohibited
  • *: Jam protection/catch protection can operate and window reverses upon reaching the fully closed position.
  • Remote switch operation:

    Operation is not possible during the LIN communication failure.