Room Temperature Sensor
|
Room temperature sensor /
Min.: -6.5°C (20.3°F)
Max.: 57.25°C (135.05°F)
|
Actual cabin temperature displayed
|
-
|
Ambient Temp Sensor
|
Ambient temperature sensor /
Min.: -23.3°C (-9.94°F)
Max.: 65.95°C (150.71°F)
|
Actual ambient temperature displayed
|
-
|
Adjusted Ambient Temp
|
Adjusted ambient temperature /
Min.: -30.8°C (-23.44°F)
Max.: 50.8°C (123.44°F)
|
-
|
-
|
Evaporator Fin Thermistor
|
Evaporator temperature sensor /
Min.: -29.7°C (-21.46°F)
Max.: 59.55°C (139.19°F)
|
Actual evaporator temperature displayed
|
-
|
Evaporator Target Temp
|
Evaporator target temperature /
Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F)
|
Evaporator target temperature displayed
|
-
|
Solar Sensor (D side)
|
Driver side solar sensor /
Min.: 0
Max.: 255
|
Driver side solar sensor value increases as brightness increases
|
-
|
Solar Sensor (P side)
|
Passenger side solar sensor /
Min.: 0
Max.: 255
|
Passenger side solar sensor value increases as brightness increases
|
-
|
Engine Coolant Temp
|
Engine coolant temperature sensor /
Min.: 1.3°C (34.34°F)
Max.: 90.55°C (194.99°F)
|
Actual engine coolant temperature displayed
|
-
|
Blower Motor Speed Level
|
Blower motor speed level /
Min.: 0
Max.: 31
|
Displayed speed level increases in range between 0 and 31 as blower motor speed increases
|
-
|
Regulator Pressure Sensor
|
Air conditioner pressure sensor/
Min.: -66.22 psi (gauge)
Max.: 477.68 psi (gauge)
|
Actual regulator pressure displayed
|
-
|
Regulator Control Current
|
Regulator control current /
Min.: 0 A
Max.: 0.997 A
|
Value changes between 0 A and 0.997 A in accordance with compressor and magnetic clutch operation
|
-
|
Room Temp Sensor (Rear)
|
Room temperature sensor /
Min.: -6.5°C (20.3°F)
Max.: 57.25°C (135.05°F)
|
Actual room temperature for front seat is displayed
|
Open in the circuit: -6.5°C (20.3°F)
Short in the circuit: 57.25°C (135.05°F)
|
Evap Temp Sens (Rear)
|
Rear evaporator temperature sensor /
Min.: -29.7°C (-21.46°F)
Max.: 59.55°C (139.19°F)
|
Actual rear evaporator temperature is displayed
|
Open in the circuit: -29.7°C (-21.46°F)
Short in the circuit: 59.55°C (139.19°F)
|
Blower Motor Level (Rear)
|
Blower motor speed level /
Min.: 0 level
Max.: 31 level
|
Increases in range between 0 and 31 as blower motor speed increases
|
-
|
Air Outlet Servo Pulse (R)
|
Rear air outlet servo motor target pulse /
Min.: 0
Max.: 255
|
FACE: 83 (pulse)
B/L: 35 (pulse)
FOOT: 7(pulse)
|
-
|
Air Outlet Servo Actual Pls(R)
|
Rear air outlet servo motor actual pulse /
Min.: 0
Max.: 255
|
FACE: 83 (pulse)
B/L: 35 (pulse)
FOOT: 7(pulse)
|
-
|
Air Mix Servo Targ Pulse(R)
|
Rear air mix servo motor target pulse /
Min.: 0
Max.: 255
|
MAX. COLD: 9 (pulse)
MAX. HOT: 54 (pulse)
|
-
|
Air Mix Servo Actual Pulse(R)
|
Rear air mix servo motor actual pulse /
Min.: 0
Max.: 255
|
MAX. COLD: 9 (pulse)
MAX. HOT: 54 (pulse)
|
-
|
Air Mix Servo Targ Pulse(D)
|
Driver side air mix servo motor target pulse /
Min.: 0
Max.: 255
|
MAX. COLD: 5 (pulse)
MAX. HOT: 103 (pulse)
|
-
|
Air Mix Servo Actual Pulse(D)
|
Driver side air mix servo motor actual pulse /
Min.: 0
Max.: 255
|
MAX. COLD: 5 (pulse)
MAX. HOT: 103 (pulse)
|
-
|
Air Mix Servo Targ Pulse(P)
|
Passenger side air mix servo motor target pulse /
Min.: 0
Max.: 255
|
MAX. COLD: 105 (pulse)
MAX. HOT: 7 (pulse)
|
-
|
Air Mix Servo Actual Pulse(P)
|
Passenger side air mix servo motor actual pulse /
Min.: 0
Max.: 255
|
MAX. COLD: 105 (pulse)
MAX. HOT: 7 (pulse)
|
-
|
Air Outlet Servo Pulse (D)
|
Air outlet servo motor target pulse /
Min.: 0
Max.: 255
|
FACE: 8 (pulse)
B/L: 30 to 38 (pulse)
FOOT: 50 to 74 (pulse)
FOOT/DEF: 80 (pulse)
DEF: 97 (pulse)
|
-
|
Air Outlet Servo Actu Pulse(D)
|
Air outlet servo motor actual pulse /
Min.: 0
Max.: 255
|
FACE: 8 (pulse)
B/L: 30 to 38 (pulse)
FOOT: 50 to 74 (pulse)
FOOT/DEF: 80 (pulse)
DEF: 97 (pulse)
|
-
|
Air Inlet Damper Targ Pulse
|
Air inlet servo motor target pulse /
Min.: 0
Max.: 255
|
RECIRCULATION: 7 (pulse)
FRESH: 28 (pulse)
|
-
|
Air Inlet Damper Actual Pulse
|
Air inlet servo motor actual pulse /
Min.: 0
Max.: 255
|
RECIRCULATION: 7 (pulse)
FRESH: 28 (pulse)
|
-
|
Shift Set Temperature
|
Shift set temperature / 2C decr, 1C decr, Normal, 1C incr, 2C incr
|
Customized value will be displayed
|
-
|
Compressor Mode
|
Compressor mode / Auto, Manual
|
Customized value will be displayed
|
-
|
Evaporator Control
|
Evaporator control / Auto, Manual
|
Customized value will be displayed
|
-
|
Foot/DEF Auto Mode
|
FOOT/DEF auto mode / ON, OFF
|
Customized value will be displayed
|
-
|
Foot/DEF Auto Blow Up
|
FOOT/DEF auto blower up function / ON, OFF
|
Customized value will be displayed
|
-
|
Flow Sensor
|
Flow sensor voltage /
Min.: 0 V
Max.: 5 V
|
Flow sensor voltage displayed
|
Open circuit: 4.7 V or more
Short circuit: 0.3 V or less
|
A/C Cutoff Signal
|
A/C Cutoff Signal / ON, OFF
|
ON: A/C cutoff signal ON
OFF: A/C cutoff signal OFF
|
-
|
Set Temperature (D side)
|
Driver side set temperature /
Min.: MAX COLD
Max.: MAX HOT
|
Driver side actual set temperature displayed
|
-
|
Set Temperature (P side)
|
Passenger side set temperature /
Min.: MAX COLD
Max.: MAX HOT
|
Passenger side actual set temperature displayed
|
-
|
Set Temperature (Rear)
|
Rear side set temperature /
Min.: MAX COLD
Max.: MAX HOT
|
Rear side actual set temperature is displayed
|
-
|
Outside Air Mode Auto Switch Function
|
Outside air mode auto switch function / ON, OFF
|
Customized value displayed
|
-
|
Number of Trouble Codes
|
Number of trouble codes /
Min.: 0
Max.: 255
|
Number of DTCs displayed
|
-
|