Last Modified: 04-05-2023 6.11:8.1.0 Doc ID: RM100000000VK11
Model Year Start: 2016 Model: Sienna Prod Date Range: [12/2015 - 08/2016]
Title: HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM: B1423/23; Pressure Sensor Circuit; 2016 MY Sienna [12/2015 - 08/2016]

DTC

B1423/23

Pressure Sensor Circuit

DESCRIPTION

This DTC is output when the refrigerant pressure is either extremely low (190 kPa [2.0 kgf/cm2, 28 psi] or less) or extremely high (3140 kPa [32.0 kgf/cm2, 455 psi] or more). The air conditioning pressure sensor, which is installed on the pipe of the high pressure side, detects the refrigerant pressure and sends refrigerant pressure signals to the air conditioning amplifier. The air conditioning amplifier determines the pressure from the signals in accordance with the sensor characteristics, and controls the compressor accordingly.

DTC Code

DTC Detection Condition

Trouble Area

B1423/23

Open or short in air conditioning pressure sensor circuit

  • Air conditioner pressure sensor
  • Harness or connector between air conditioner pressure sensor and air conditioning amplifier
  • Air conditioning amplifier

WIRING DIAGRAM

PROCEDURE

1.

CHECK REFRIGERANT PRESSURE

(a) Install the manifold gauge set (See page 2016 - 2020 MY Sienna [12/2015 -        ]; HEATING / AIR CONDITIONING: REFRIGERANT: ON-VEHICLE INSPECTION ).

(b) Read the manifold gauge pressure when the following conditions are established.

(1) Prepare the vehicle in accordance with the chart below.

Item

Condition

Engine speed

1500 rpm

Vehicle doors

Fully open

Temperature setting

MAX COLD

Blower speed

HI

A/C switch

ON

Air inlet

RECIRC

(2) When the refrigerant volume is correct, the gauge reading indicates as follows:

Standard:

Tester Connection

Refrigerant Pressure

Low pressure side

150 to 250 kPa (1.5 to 2.5 kg/cm2, 22 to 36 psi)

High pressure side

1370 to 1570 kPa (14.0 to 16.0 kg/cm2, 199 to 228 psi)

HINT:

Pressure varies in accordance with certain conditions such as outside air temperature, sunlight and wind.

NG

CHARGE REFRIGERANT

OK

2.

READ VALUE USING TECHSTREAM (REG PRESS SENS)

(a) Connect Techstream to the DLC3.

(b) Turn the ignition switch to ON.

(c) Turn the Techstream on.

(d) Enter the following menus: Body Electrical / Air Conditioner / Data List.

(e) Check the value(s) by referring to the table below.

Air Conditioner

Tester Display

Measurement Item/Range

Normal Condition

Diagnostic Note

Regulator Pressure Sensor

Air conditioner pressure sensor/

Min.: -66.22 psi (gauge)

Max.: 477.68 psi (gauge)

Actual regulator pressure displayed

-

OK:

The display is as specified in the normal condition column.

Result

Result

Proceed to

NG

A

OK (When troubleshooting according to Problem Symptoms Table)

B

OK (When troubleshooting according to the DTC)

C

B

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE

C

REPLACE AIR CONDITIONING AMPLIFIER

A

3.

CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER)

(a) Disconnect the air conditioner pressure sensor connector.

(b) Disconnect the air conditioning amplifier connector.

(c) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

A32-3 (+) - D75-10 (S5-3)

Always

Below 1 Ω

A32-2 (PR) - D75-9 (PRE)

Always

Below 1 Ω

A32-1 (-) - D75-13 (SG-2)

Always

Below 1 Ω

A32-3 (+) - Body ground

Always

10 kΩ or higher

A32-2 (PR) - Body ground

Always

10 kΩ or higher

A32-1 (-) - Body ground

Always

10 kΩ or higher

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

OK

4.

INSPECT AIR CONDITIONING AMPLIFIER

(a) Remove the air conditioning amplifier with its connectors still connected.

(b) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

D75-13 (SG-2) - Body ground

Always

Below 1 Ω

Text in Illustration

*a

Component with harness connected

(Air Conditioning Amplifier)

(c) Turn the ignition switch to ON.

(d) Measure the voltage according to the value(s) in the table below.

Standard Voltage:

Tester Connection

Switch Condition

Specified Condition

D75-10 (S5-3) - D75-13 (SG-2)

Ignition switch ON (A/C ON)

4.75 to 5.25 V

NG

REPLACE AIR CONDITIONING AMPLIFIER

OK

5.

INSPECT AIR CONDITIONER PRESSURE SENSOR

(a) Remove the air conditioning amplifier with its connectors still connected.

(b) Set the manifold gauge.

(c) Warm up the engine.

(d) Turn the A/C switch ON.

(e) Measure the voltage according to the value(s) in the table below.

Standard Voltage:

Tester Connection

Refrigerant Pressure

Specified Condition

D75-9 (PRE) - D75-13 (SG-2)

176 to 3025 kPa (1.8 to 30.9 kgf/cm2, 26 to 438 psi)

0.63 to 4.72 V

Text in Illustration

*a

Component without harness connected

(Air Conditioning Amplifier)

OK

REPLACE AIR CONDITIONING AMPLIFIER

NG

REPLACE AIR CONDITIONER PRESSURE SENSOR