Last Modified: 04-05-2023 |
6.11:8.1.0 |
Doc ID: RM100000000VK0Y |
Model Year Start: 2016 |
Model: Sienna |
Prod Date Range: [12/2015 -
] |
Title: HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM: B1413/13; Evaporator Temperature Sensor Circuit; 2016 - 2020 MY Sienna [12/2015 - ] |
DTC
|
B1413/13
|
Evaporator Temperature Sensor Circuit
|
DESCRIPTION
The evaporator temperature sensor is installed on the evaporator in the air conditioning unit to detect the cooled air temperature that has passed through the evaporator and to control the air conditioning. It sends appropriate signals to the air conditioning amplifier. The resistance of the evaporator temperature sensor changes in accordance with the cooled air temperature that has passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier applies voltage (5 V) to the evaporator temperature sensor and reads voltage changes as the resistance of the evaporator temperature sensor changes. This sensor is used for frost prevention.
DTC Code
|
DTC Detection Condition
|
Trouble Area
|
B1413/13
|
Open or short in evaporator temperature sensor circuit
|
-
Evaporator temperature sensor
-
Air conditioning harness
-
Air conditioning amplifier
|
WIRING DIAGRAM
PROCEDURE
1.
|
READ VALUE USING TECHSTREAM
|
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Air Conditioner / Data List.
(e) Check the value(s) by referring to the table below.
Air Conditioner
Tester Display
|
Measurement Item/Range
|
Normal Condition
|
Diagnostic Note
|
Evaporator Fin Thermistor
|
Evaporator temperature sensor /
Min.: -30°C (-22°F)
Max.: 59.6°C (139.28°F)
|
Actual evaporator temperature displayed
|
-
|
OK:
The display is as specified in the Normal Condition column.
Result
Result
|
Proceed to
|
NG
|
A
|
OK (When troubleshooting according to Problem Symptoms Table)
|
B
|
OK (When troubleshooting according to the DTC)
|
C
|
B |
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE
(See page
)
|
A
|
|
|
2.
|
INSPECT EVAPORATOR TEMPERATURE SENSOR
|
(a) Remove the evaporator temperature sensor.
(b) Disconnect the evaporator temperature sensor connector.
(c) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
e2-1 - e2-2
|
-10°C (14°F)
|
7.30 to 9.10 kΩ
|
e2-1 - e2-2
|
-5°C (23°F)
|
5.65 to 6.95 kΩ
|
e2-1 - e2-2
|
0°C (32°F)
|
4.40 to 5.35 kΩ
|
e2-1 - e2-2
|
5°C (41°F)
|
3.40 to 4.15 kΩ
|
e2-1 - e2-2
|
10°C (50°F)
|
2.70 to 3.25 kΩ
|
e2-1 - e2-2
|
15°C (59°F)
|
2.14 to 2.58 kΩ
|
e2-1 - e2-2
|
20°C (68°F)
|
1.71 to 2.05 kΩ
|
e2-1 - e2-2
|
25°C (77°F)
|
1.38 to 1.64 kΩ
|
e2-1 - e2-2
|
30°C (86°F)
|
1.11 to 1.32 kΩ
|
NOTICE:
-
Hold the sensor only by its connector. Touching the sensor may change the resistance value.
-
When measuring, the sensor temperature must be the same as the ambient temperature.
HINT:
As the temperature increases, the resistance decreases (see the graph).
Text in Illustration
*a
|
Component without harness connected
(Evaporator Temperature Sensor)
|
*b
|
Sensing Portion
|
OK
|
|
|
3.
|
INSPECT AIR CONDITIONING HARNESS (AIR CONDITIONING AMPLIFIER - EVAPORATOR TEMPERATURE SENSOR)
|
(a) Remove the air conditioning harness.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
z1-6 (TEA) - e2-2
|
Always
|
Below 1 Ω
|
z1-5 (SGA) - e2-1
|
Always
|
Below 1 Ω
|
z1-6 (TEA) - Body ground
|
Always
|
10 kΩ or higher
|
z1-5 (SGA) - Body ground
|
Always
|
10 kΩ or higher
|
NG |
|
REPLACE AIR CONDITIONING HARNESS
(See page
)
|
|