Last Modified: 04-05-2023 |
6.11:8.1.0 |
Doc ID: RM100000000VJUP |
Model Year Start: 2016 |
Model: Sienna |
Prod Date Range: [12/2015 -
] |
Title: SEAT: AUTO ACCESS SEAT SYSTEM: FAIL-SAFE CHART; 2016 - 2020 MY Sienna [12/2015 - ] |
FAIL-SAFE CHART
1. AUTO ACCESS SEAT OPERATION IN FAIL-SAFE MODE
(a) If there is a malfunction in any motor or switch, auto access seat operation is prohibited.
(1) Power Supply Unstable
Applicable Mode
|
Access Seat Mode
|
Power Seat Mode
|
Independent Operation Mode
|
Service Operation Mode
|
○
|
○
|
○
|
○
|
Result of Fail-safe Operation
|
Detection Condition
|
Fail-safe Control Method
|
Fail-safe Deactivation Condition
|
System function suspended
|
Low voltage/high voltage detected
-
Voltage reduced
-
Power source disconnected
-
High voltage
|
-
Motor output prohibited
-
DTC detection prohibited
-
Buzzer sounding prohibited
|
Voltage recovery conditions met and operation switch off detected
|
(2) Motor Malfunction
Applicable Mode
|
Access Seat Mode
|
Power Seat Mode
|
Independent Operation Mode
|
Service Operation Mode
|
|
○
|
○
|
○
|
|
|
Applicable Motor
|
Reclining Motor
|
Front-rear Slide Motor
|
Swivel Motor
|
Outward Slide Motor
|
Up-down Motor
|
○
|
○
|
○
|
○
|
○
|
DTC
|
Reclining Motor Error
|
Front-rear Slide Motor Error
|
Swivel Motor Error
|
Outward Slide Motor Error
|
Up-down Motor Error
|
11
|
12
|
13
|
14
|
15
|
Result of Fail-safe Operation
|
Detection Condition
|
Fail-safe Control Method
|
Fail-safe Deactivation Condition
|
Operation of all motors prohibited
|
For a stopped motor, 32 edges or more are detected in a 0.5 second period
|
Motor temporarily stopped + buzzer (C) sounds → position information erased, change to independent operation mode → operation of all motors prohibited, diagnostic code stored in RAM
|
Diagnostic code cleared in service operation mode or by power supply off
|
(3) Pulse Not Generated
Applicable Mode
|
Access Seat Mode
|
Power Seat Mode
|
Independent Operation Mode
|
Service Operation Mode
|
|
○
|
|
|
|
|
Applicable Motor
|
Reclining Motor
|
Front-rear Slide Motor
|
Swivel Motor
|
Outward Slide Motor
|
Up-down Motor
|
○
|
○
|
○
|
○
|
○
|
Applicable Mode
|
Access Seat Mode
|
Power Seat Mode
|
Independent Operation Mode
|
Service Operation Mode
|
|
|
○
|
|
|
|
Applicable Motor
|
Reclining Motor
|
Front-rear Slide Motor
|
Swivel Motor
|
Outward Slide Motor
|
Up-down Motor
|
|
○
|
|
|
|
DTC
|
Reclining Pulse Error
|
Front-rear Slide Pulse Error
|
Swivel Pulse Error
|
Outward Slide Pulse Error
|
Up-down Pulse Error
|
21
|
22
|
23
|
24
|
25
|
Result of Fail-safe Operation
|
Detection Condition
|
Fail-safe Control Method
|
Fail-safe Deactivation Condition
|
System function suspended
|
When the applicable motor is operating and the mask time passes without even 1 edge being output, and this occurs 7 times
|
Operation halted, buzzer (C) sounds → position information erased, change to independent operation mode
|
-
Diagnostic code cleared in service operation mode or by power supply off
-
Origin point position information calibrated in independent operation mode
|
(4) Limit Switch Malfunction
Applicable Mode
|
Access Seat Mode
|
Power Seat Mode
|
Independent Operation Mode
|
Service Operation Mode
|
|
○
|
|
|
|
|
Applicable Motor
|
|
Reclining Motor
|
Front-rear Slide Motor
|
Swivel Motor
|
Outward Slide Motor
|
Up-down Motor
|
Stuck ON Malfunction
|
○
|
○
|
○
|
○
|
○
|
Except Limit Switch Area
|
○
|
|
○
|
○
|
○
|
Past Limit Switch Area
|
|
○
|
|
|
|
Within Mechanical Lock Area
|
|
○
|
|
|
|
Mechanical Lock Excessive Load Detected
|
|
|
○
|
○
|
○
|
Applicable Mode
|
Access Seat Mode
|
Power Seat Mode
|
Independent Operation Mode
|
Service Operation Mode
|
|
|
○
|
|
|
|
Applicable Motor
|
|
Reclining Motor
|
Front-rear Slide Motor
|
Swivel Motor
|
Outward Slide Motor
|
Up-down Motor
|
Stuck ON Malfunction
|
○
|
○
|
|
|
|
Except Limit Switch Area
|
○
|
|
|
|
|
Limit Switch ON → OFF Detected
|
|
|
○
|
○
|
○
|
Past Limit Switch Area
|
|
○
|
|
|
|
Within Mechanical Lock Area
|
|
○
|
|
|
|
DTC
|
Reclining Pulse Error
|
Front-rear Slide Pulse Error
|
Swivel Pulse Error
|
Outward Slide Pulse Error
|
Up-down Pulse Error
|
41
|
42
|
43
|
44
|
45
|
Result of Fail-safe Operation
|
Detection Condition
|
Fail-safe Control Method
|
Fail-safe Deactivation Condition
|
Egress prohibited
Ingress allowed
|
Limit switch logic and pulse count do not match
-
Limit switch logic judged to be abnormal
|
During Access Seat Mode:
-
Operation halted, buzzer (C) sounds → egress prohibited, ingress allowed
During Power Seat Mode:
-
Operation halted, buzzer (C) sounds → egress prohibited, forced ingress operation allowed
|
-
Diagnostic code cleared in service operation mode or by power supply off
During Access Seat Mode:
During Power Seat Mode:
-
Forced ingress by No. 2 power seat switch (ingress switch)
|
(5) Mechanical Lock Non-detection Malfunction
Applicable Mode
|
Access Seat Mode
|
Power Seat Mode
|
Independent Operation Mode
|
Service Operation Mode
|
|
○
|
|
|
|
|
Applicable Motor
|
Reclining Motor
|
Front-rear Slide Motor
|
Swivel Motor
|
Outward Slide Motor
|
Up-down Motor
|
|
|
○
|
|
|
DTC
|
Mechanical Lock Undetection Error
|
73
|
Result of Fail-safe Operation
|
Detection Condition
|
Fail-safe Control Method
|
Fail-safe Deactivation Condition
|
System function suspended
|
While swivel motor is operating in the egress direction, the swivel motor position passes the end of the mechanical lock (+ margin-of-error pulse) but mechanical lock excessive load is not detected
|
Operation halted + buzzer (C) sounds → position information erased, change to independent operation mode
|
-
Diagnostic code cleared in service operation mode or by power supply off
-
Origin point position information calibrated in independent operation mode
|
(6) Pulse Out-of-sync
Applicable Mode
|
Access Seat Mode
|
Power Seat Mode
|
Independent Operation Mode
|
Service Operation Mode
|
|
○
|
|
|
|
|
Applicable Motor
|
Reclining Motor
|
Front-rear Slide Motor
|
Swivel Motor
|
Outward Slide Motor
|
Up-down Motor
|
|
○
|
○
|
○
|
|
DTC
|
Pulse Differential
|
31
|
Result of Fail-safe Operation
|
Detection Condition
|
Fail-safe Control Method
|
Fail-safe Deactivation Condition
|
System function suspended
|
When the basic pulse out-of-sync for two applicable motors is 160 edges or more for 0.2 continuous seconds
In 0.2 continuous seconds, 202 edges or more are detected even once
|
Operation halted, buzzer (C) sounds → position information erased, change to independent operation mode
|
-
Diagnostic code cleared in service operation mode or by power supply off
-
Origin point position information calibrated in independent operation mode
|
When the basic pulse out-of-sync for two applicable motors is 160 edges or more for 0.2 continuous seconds
|
Operation halted, buzzer (H) sounds → pressing the operated switch again will not cause the buzzer to sound
|
-
All operated switches detected as off
-
Basic pulse out-of-sync detected as less than 160 edges
|
(7) Multiple Operation Switches Pressed
Applicable Mode
|
Access Seat Mode
|
Power Seat Mode
|
Independent Operation Mode
|
Service Operation Mode
|
○
|
○
|
○
|
|
Operated Switches
|
All operated switches (including seat control transmitter)
|
Result of Fail-safe Operation
|
Detection Condition
|
Fail-safe Control Method
|
Fail-safe Deactivation Condition
|
System function suspended
|
During Access Seat Mode:
-
Detection that 2 or more operation switches are pressed at the same time
During Power Seat Mode:
-
Detection that 2 or more operation switches are pressed at the same time
During Independent Operation Mode:
-
Detection that 2 or more operation switches without a combined function after function change are pressed at the same time
-
Detection that a third operation switch with combined function after change is ON
|
During Operation:
-
Operation halted → no effect when operation switch pressed again
During Operation Halt:
-
Operation halt continues → no effect when switch pressed again
|
Detection that all operation switches are off
|
(8) Operating Conditions Not Met 1
Applicable Mode
|
Access Seat Mode
|
Power Seat Mode
|
Independent Operation Mode
|
Service Operation Mode
|
○
|
|
○
|
|
Applicable Signal
|
Shift P Signal
|
Result of Fail-safe Operation
|
Detection Condition
|
Fail-safe Control Method
|
Fail-safe Deactivation Condition
|
Egress prohibited
Ingress prohibited
|
During IG ON, shift P signal off detected
|
During Operation:
-
Operation halted + buzzer (D) sounds → egress prohibited, ingress prohibited → no effect when switch pressed again (buzzer (D) continues to sound)
During Operation Halt:
-
Buzzer (D) sounds → egress prohibited, ingress prohibited → no effect when switch pressed again (buzzer (D) continues to sound)
|
-
Ignition switch off
-
Shift P signal ON detected
-
Change to power seat mode
|
(9) Operating Conditions Not Met 2
Applicable Mode
|
Access Seat Mode
|
Power Seat Mode
|
Independent Operation Mode
|
Service Operation Mode
|
○
|
|
○
|
|
Applicable Signal
|
Power Slide Door RH Fully Open Signal
|
Result of Fail-safe Operation
|
Detection Condition
|
Fail-safe Control Method
|
Fail-safe Deactivation Condition
|
Operation halted
|
Power slide door RH fully open signal off detected
|
During Access Seat Mode (during operation):
-
Operation halted + buzzer (G) sounds → ingress allowed + buzzer (D) sounds → egress prohibited + buzzer (G) sounds
During Access Seat Mode (when stopped):
-
Buzzer (G) sounds → ingress allowed + buzzer (D) sounds, egress prohibited + buzzer (G) sounds
During Independent Operation Mode:
-
Buzzer (G) sounds → no restrictions, buzzer does not sound if operation switch pressed again
|
-
Power slide door RH fully open signal ON detected
-
Change to power seat mode
|
(10) Operating Conditions Not Met 3
Applicable Mode
|
Access Seat Mode
|
Power Seat Mode
|
Independent Operation Mode
|
Service Operation Mode
|
○
|
|
○
|
|
Applicable Signal
|
Buckle Switch Signal
|
Result of Fail-safe Operation
|
Detection Condition
|
Fail-safe Control Method
|
Fail-safe Deactivation Condition
|
Operation halted
|
Seat belt fastened
|
During Access Seat Mode (during operation):
-
Operation halted + buzzer (G) sounds → ingress allowed, egress prohibited + buzzer (G) sounds
During Access Seat Mode (when stopped):
-
Buzzer (G) sounds → ingress allowed, egress prohibited + buzzer (G) sounds
During Independent Operation Mode:
-
Buzzer (G) sounds → no restrictions, buzzer does not sound if operation switch pressed again.
|
Detection that seat belt is unfastened
|
(11) Pulse Sensor Short
Applicable Mode
|
Access Seat Mode
|
Power Seat Mode
|
Independent Operation Mode
|
Service Operation Mode
|
○
|
○
|
○
|
○
|
Result of Fail-safe Operation
|
Detection Condition
|
Fail-safe Control Method
|
Fail-safe Deactivation Condition
|
Operation halted
|
Voltage drop (6.5 V or lower) detected
|
-
Motor output prohibited
-
DTC output prohibited
-
Sounding of buzzer prohibited
|
-
Conditions for voltage recovery met and operated switches detected as off
-
Power supply reconnected and all operated switches detected as off
|
(12) Buckle Failure
Applicable Mode
|
Access Seat Mode
|
Power Seat Mode
|
Independent Operation Mode
|
Service Operation Mode
|
○
|
○
|
○
|
|
Applicable Signal
|
Buckle Switch Signal
|
DTC
|
Buckle Failure
|
81
|
Result of Fail-safe Operation
|
Detection Condition
|
Fail-safe Deactivation Condition
|
Operation halted
|
Cannot confirm that seat belt is fastened or unfastened for 1.0 seconds or more
|
Confirmation of seat belt fastened/unfastened status
|
(13) Motor Continuously Energized
Applicable Mode
|
Access Seat Mode
|
Power Seat Mode
|
Independent Operation Mode
|
Service Operation Mode
|
|
○
|
○
|
○
|
|
|
Applicable Motor
|
Reclining Motor
|
Front-rear Slide Motor
|
Swivel Motor
|
Outward Slide Motor
|
Up-down Motor
|
○
|
○
|
○
|
○
|
○
|
Result of Fail-safe Operation
|
Detection Condition
|
Fail-safe Control Method
|
Fail-safe Deactivation Condition
|
Operation halted
|
Applicable motor is continuously energized for 60 seconds or more
|
Operation halted → all operation switches detected as off → wait for operation switch input
|
All operation switches detected as off
|
(14) Outside of Area Error
Applicable Mode
|
Access Seat Mode
|
Power Seat Mode
|
Independent Operation Mode
|
Service Operation Mode
|
|
○
|
○
|
○
|
|
|
Applicable Motor
|
Reclining Motor
|
Front-rear Slide Motor
|
Swivel Motor
|
Outward Slide Motor
|
Up-down Motor
|
○
|
○
|
○
|
○
|
○
|
Result of Fail-safe Operation
|
Detection Condition
|
Fail-safe Control Method
|
Fail-safe Deactivation Condition
|
Operation halted
|
Applicable motor goes beyond the mechanical lock area
|
Operation halted + buzzer (C) sounds → position information erased, change to independent operation mode
|
Position information initialized in independent operation mode
|
|