Title: SUPPLEMENTAL RESTRAINT SYSTEMS: AIRBAG SYSTEM: B1835/58-B1838/58; Short in Curtain Shield Squib LH Circuit; 2016 - 2020 MY Sienna [12/2015 - ] |
DTC
|
B1835/58
|
Short in Curtain Shield Squib LH Circuit
|
DTC
|
B1836/58
|
Open in Curtain Shield Squib LH Circuit
|
DTC
|
B1837/58
|
Short to GND in Curtain Shield Squib LH Circuit
|
DTC
|
B1838/58
|
Short to B+ in Curtain Shield Squib LH Circuit
|
DESCRIPTION
The curtain shield squib LH circuit consists of the center airbag sensor assembly and the curtain shield airbag assembly LH.
The circuit instructs the SRS to deploy when deployment conditions are met.
These DTCs are recorded when a malfunction is detected in the curtain shield squib LH circuit.
DTC No.
|
DTC Detection Condition
|
Trouble Area
|
B1835/58
|
When one of following conditions is met:
-
The center airbag sensor assembly receives a line short circuit signal 5 times in the curtain shield squib LH circuit during primary check.
-
Curtain shield squib LH malfunction
-
Center airbag sensor assembly malfunction
|
-
Floor wire
-
Curtain shield airbag assembly LH (Curtain shield squib LH)
-
Center airbag sensor assembly
|
B1836/58
|
When one of following conditions is met:
-
The center airbag sensor assembly receives an open circuit signal in the curtain shield squib LH circuit for 2 seconds.
-
Curtain shield squib LH malfunction
-
Center airbag sensor assembly malfunction
|
-
Floor wire
-
Curtain shield airbag assembly LH (Curtain shield squib LH)
-
Center airbag sensor assembly
|
B1837/58
|
When one of following conditions is met:
-
The center airbag sensor assembly receives a short circuit to ground signal in the curtain shield squib LH circuit for 0.5 seconds.
-
Curtain shield squib LH malfunction
-
Center airbag sensor assembly malfunction
|
-
Floor wire
-
Curtain shield airbag assembly LH (Curtain shield squib LH)
-
Center airbag sensor assembly
|
B1838/58
|
When one of following conditions is met:
-
The center airbag sensor assembly receives a short circuit to B+ signal in the curtain shield squib LH circuit for 0.5 seconds.
-
Curtain shield squib LH malfunction
-
Center airbag sensor assembly malfunction
|
-
Floor wire
-
Curtain shield airbag assembly LH (Curtain shield squib LH)
-
Center airbag sensor assembly
|
WIRING DIAGRAM
CAUTION / NOTICE / HINT
HINT:
-
Perform the simulation method by selecting Check Mode (signal check) with the Techstream (See page
).
-
After selecting Check Mode (signal check), perform the simulation method by wiggling each connector of the airbag system or driving the vehicle on various types of roads (See page
).
PROCEDURE
(a) Turn the ignition switch off.
(b) Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
(c) Check that the connector is properly connected to the curtain shield airbag assembly LH.
OK:
The connector is properly connected.
HINT:
If the connector is not connected securely, reconnect the connector and proceed to the next inspection.
(d) Disconnect the connector from the curtain shield airbag assembly LH.
(e) Check that the floor wire connector (on the curtain shield airbag assembly LH side) is not damaged.
OK:
The lock button is not disengaged, and the claw of the lock is not deformed or damaged.
NG |
|
REPLACE FLOOR WIRE
|
OK
|
|
|
2.
|
CHECK CURTAIN SHIELD AIRBAG ASSEMBLY LH (CURTAIN SHIELD SQUIB LH)
|
SST: 09843-18061
(a) Connect SST (resistance: 2.1 Ω) to connector C.
CAUTION:
Never connect the tester to the curtain shield airbag assembly LH (curtain shield squib LH) for measurement, as this may lead to a serious injury due to airbag deployment.
NOTICE:
-
Do not forcibly insert SST into the terminals of the connector when connecting SST.
-
Insert SST straight into the terminals of the connector.
(b) Connect the cable to the negative battery terminal, and wait for at least 2 seconds.
(c) Turn the ignition switch to ON, and wait for at least 60 seconds.
(d) Clear the DTCs stored in the memory (See page
).
(e) Turn the ignition switch off.
(f) Turn the ignition switch to ON, and wait for at least 60 seconds.
(g) Check for DTCs (See page
).
OK:
DTC B1835/58, B1836/58, B1837/58 or B1838/58 is not output.
Text in Illustration
*1
|
Curtain Shield Squib LH
|
*2
|
Center Airbag Sensor Assembly
|
*3
|
Connector C
|
*a
|
Front view of wire harness connector
(to Curtain Shield Squib LH)
|
HINT:
DTCs other than B1835/58, B1836/58, B1837/58 and B1838/58 may be output at this time, but they are not related to this check.
NG
|
|
|
(a) Turn the ignition switch off.
(b) Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
(c) Disconnect SST from connector C.
(d) Check that the connector is properly connected to the center airbag sensor assembly.
OK:
The connector is properly connected.
HINT:
If the connector is not connected securely, reconnect the connector and proceed to the next inspection.
(e) Disconnect the connector from the center airbag sensor assembly.
(f) Check that the terminal of the connector is not damaged.
OK:
The terminal is not deformed or damaged.
(g) Check that the short spring for the floor wire connector with the activation prevention mechanism is not deformed or damaged.
OK:
The short spring is not deformed or damaged.
NG |
|
REPLACE FLOOR WIRE
|
OK
|
|
|
4.
|
CHECK FLOOR WIRE (CURTAIN SHIELD SQUIB LH - CENTER AIRBAG SENSOR ASSEMBLY)
|
(a) Connect the cable to the negative battery terminal, and wait for at least 2 seconds.
(b) Turn the ignition switch to ON.
(c) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
|
Switch Condition
|
Specified Condition
|
K12-2 (ICL-) - Body ground
|
Ignition switch ON
|
Below 1 V
|
K12-1 (ICL+) - Body ground
|
Ignition switch ON
|
Below 1 V
|
Text in Illustration
*1
|
Curtain Shield Squib LH
|
*2
|
Center Airbag Sensor Assembly
|
*3
|
Floor Wire
|
*4
|
Connector C
|
*a
|
Front view of wire harness connector
(to Curtain Shield Squib LH)
|
(d) Turn the ignition switch off.
(e) Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
(f) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
K12-2 (ICL-) - K12-1 (ICL+)
|
Always
|
Below 1 Ω
|
(g) Release the activation prevention mechanism built into connector B (See page
).
(h) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
K12-2 (ICL-) - K12-1 (ICL+)
|
Always
|
1 MΩ or higher
|
K12-2 (ICL-) - Body ground
|
Always
|
1 MΩ or higher
|
K12-1 (ICL+) - Body ground
|
Always
|
1 MΩ or higher
|
NG |
|
REPLACE FLOOR WIRE
|
OK
|
|
|
5.
|
CHECK CENTER AIRBAG SENSOR ASSEMBLY
|
(a) Restore the released activation prevention mechanism of connector B to the original condition.
(b) Connect the connectors to the curtain shield airbag assembly LH and the center airbag sensor assembly.
(c) Connect the cable to the negative battery terminal, and wait for at least 2 seconds.
(d) Turn the ignition switch to ON, and wait for at least 60 seconds.
(e) Clear the DTCs stored in the memory (See page
).
(f) Turn the ignition switch off.
(g) Turn the ignition switch to ON, and wait for at least 60 seconds.
(h) Check for DTCs (See page
).
OK:
DTC B1835/58, B1836/58, B1837/58 or B1838/58 is not output.
Text in Illustration
*1
|
Curtain Shield Squib LH
|
*2
|
Center Airbag Sensor Assembly
|
HINT:
DTCs other than B1835/58, B1836/58, B1837/58 and B1838/58 may be output at this time, but they are not related to this check.
|