Last Modified: 04-05-2023 6.11:8.1.0 Doc ID: RM100000000VJO0
Model Year Start: 2016 Model: Sienna Prod Date Range: [12/2015 -           ]
Title: METER / GAUGE / DISPLAY: METER / GAUGE SYSTEM: Entire Combination Meter does not Operate; 2016 - 2020 MY Sienna [12/2015 -        ]

Entire Combination Meter does not Operate

DESCRIPTION

This circuit is the power source circuit for the meter. This circuit provides two types of power sources, one is a constant power source mainly used as a backup power source, and the other is an IG power source mainly used for signal transmission. The constant power source is mainly used as a backup power source for the meter CPU, however, it is also used for CAN communication. If a voltage of 12 V is not applied to terminal IG+ when turning the ignition switch ON, the indicators will not operate.

WIRING DIAGRAM

CAUTION / NOTICE / HINT

CAUTION:

Inspect the fuses for circuits related to this system before performing the following inspection procedure.

PROCEDURE

1.

CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - BATTERY AND BODY GROUND)

(a) Disconnect the combination meter assembly connector.

(b) Measure the voltage according to the value(s) in the table below.

Standard Voltage:

Tester Connection

Switch Condition

Specified Condition

D145-13 (IG+) - Body ground

Ignition switch ON

11 to 14 V

D145-1 (B) - Body ground

Always

11 to 14 V

(c) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

D145-20 (ES) - Body ground

Always

Below 1 Ω

Text in Illustration

*a

Front view of wire harness connector

(to Combination Meter Assembly)

OK

REPLACE COMBINATION METER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR