Last Modified: 04-05-2023 6.11:8.1.0 Doc ID: RM100000000VIKS
Model Year Start: 2016 Model: Sienna Prod Date Range: [12/2015 - 08/2016]
Title: U660E (AUTOMATIC TRANSMISSION / TRANSAXLE): AUTOMATIC TRANSAXLE SYSTEM: P0712,P0713; Transmission Fluid Temperature Sensor "A" Circuit Low Input; 2016 MY Sienna [12/2015 - 08/2016]

DTC

P0712

Transmission Fluid Temperature Sensor "A" Circuit Low Input

DTC

P0713

Transmission Fluid Temperature Sensor "A" Circuit High Input

DESCRIPTION

The Automatic Transmission Fluid (ATF) temperature sensor converts the fluid temperature into a resistance value for use by the TCM.

The TCM applies a voltage to the temperature sensor through terminal THO1 of the TCM.

The sensor resistance changes with the ATF temperature. As the temperature becomes higher, the sensor resistance decreases.

One terminal of the sensor is grounded so that the sensor resistance decreases and the voltage goes down as the temperature becomes higher.

The TCM calculates the fluid temperature based on the voltage signal.

DTC No.

DTC Detection Condition

Trouble Area

P0712

ATF temperature sensor resistance is less than 79 Ω for 0.5 seconds or more (1 trip detection logic)

  • Short in ATF temperature sensor circuit
  • Transmission wire
  • ATF temperature sensor
  • TCM

P0713

ATF temperature sensor resistance is more than 156 kΩ for 0.5 seconds or more. Either of the following conditions is met (1 trip detection logic):

  • Open in ATF temperature sensor circuit
  • Transmission wire
  • ATF temperature sensor
  • TCM

Condition (A): 5 minutes and 35 seconds or more have elapsed after the engine start when engine coolant temperature or intake air temperature is -29.375°C (-20.875°F) or less.

Condition (B): 10 seconds or more have elapsed after the engine start when engine coolant temperature and intake air temperature are more than -29.375°C (- 20.875°F).

MONITOR DESCRIPTION

These DTCs indicate an open or short in the ATF temperature sensor circuit. The ATF temperature sensor converts ATF temperature into an electrical resistance value. Based on the resistance, the TCM determines the ATF temperature, and the TCM detects an open or short in the ATF temperature circuit. If the resistance value of the ATF temperature is less than 79 Ω*1 or more than 156 kΩ*2, the TCM interprets this as a fault in the ATF sensor or wiring. The TCM will turn on the MIL and store the DTC.

*1: 150°C (302°F) or more is indicated regardless of the actual ATF temperature.

*2: -40°C (-40°F) is indicated regardless of the actual ATF temperature.

HINT:

The ATF temperature can be checked on the Techstream display.

MONITOR STRATEGY

Related DTCs

P0712: ATF temperature sensor/Range check (Low voltage)

P0713: ATF temperature sensor/Range check (High voltage)

Required sensors/Components

ATF temperature sensor

Frequency of operation

Continuous

Duration

0.5 seconds

MIL operation

Immediate

Sequence of operation

None

TYPICAL ENABLING CONDITIONS

  • P0712: Range check (Low voltage)

    The monitor will run whenever these DTCs are not present.

    None

    Battery voltage

    8 V or more

    Ignition switch

    ON

P0713: Range check (High voltage)

  • One of the following conditions is met: Condition (A) or (B)

    Condition (A)

    Engine coolant temperature (ECT) or intake air temperature (IAT) at engine start

    -29.375°C (-20.875°F) or less

    Time after engine start

    5 minutes and 35 seconds or more

    ECT sensor circuit fail (P0115, P0117, P0118)

    Not detected

    IAT sensor circuit fail (P0112, P0113)

    Not detected

    Condition (B)

    Engine coolant temperature (ECT) or intake air temperature (IAT) at engine start

    More than -29.375°C (-20.875°F)

    Time after engine start

    10 seconds or more

    ECT sensor circuit fail (P0115, P0117, P0118)

    Not detected

    IAT sensor circuit fail (P0112, P0113)

    Not detected

TYPICAL MALFUNCTION THRESHOLDS

P0712: Range check (Low voltage)

ATF temperature sensor voltage

(ATF temperature sensor output temperature)

Less than 0.14 V

(Higher than 164°C (327.2°F))

P0713: Range check (High voltage)

ATF temperature sensor voltage

(ATF temperature sensor output temperature)

More than 4.91 V

(Less than -48°C (-54.4°F))

COMPONENT OPERATING RANGE

ATF temperature sensor voltage

(ATF temperature sensor output temperature)

0.14 to 4.91 V

(-48 to 164°C (-54.4 to 327.2°F))

WIRING DIAGRAM

CAUTION / NOTICE / HINT

NOTICE:

Perform the universal trip to clear permanent DTCs (See page 2016 MY Sienna [12/2015 - 08/2016]; U660E (AUTOMATIC TRANSMISSION / TRANSAXLE): AUTOMATIC TRANSAXLE SYSTEM: DTC CHECK / CLEAR ).

HINT:

Using the Techstream to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

NOTICE:

In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.

  1. Warm up the engine.
  2. Turn the ignition switch off.
  3. Connect the Techstream to the DLC3.
  4. Turn the ignition switch to ON.
  5. Turn the Techstream on.
  6. Enter the following menus: Powertrain / ECT / Data List / All Data.
  7. According to the display on the Techstream, read the Data List.

    ECT

    Tester Display

    Measurement Item/Range

    Normal Condition

    Diagnostic Note

    A/T Oil Temperature 1

    ATF temperature sensor value/

    Min.: -40°C (-40°F)

    Max.: 150°C (302°F)

    • After stall speed test: Approximately 80°C (176°F)
    • While engine is cold:

      Equal to ambient temperature

    If value is -40°C (-40°F) or 150°C (302°F), ATF temperature sensor circuit is open or short circuited

    HINT:

    When DTC P0712 is output and the Techstream indicates 150°C (302°F) or more, there is a short circuit.

    When DTC P0713 is output and the Techstream indicates -40°C (-40°F), there is an open circuit.

    Measure the resistance between terminal THO1 (OT) and body ground.

    Temperature Displayed

    Malfunction

    -40°C (-40°F)

    Open circuit

    150°C (302°F) or more

    Short circuit

    HINT:

    If the circuit related to the ATF temperature sensor becomes open, P0713 is immediately set (in 0.5 seconds). When P0713 is set, P0711 cannot be detected.

    It is not necessary to inspect the circuit when P0711 is set.

PROCEDURE

1.

INSPECT TRANSMISSION WIRE (ATF TEMPERATURE SENSOR)

(a) Remove the TCM from the transaxle.

(b) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

17 (E2) - 18 (THO1)

Always

79 Ω to 156 kΩ

17 (E2) - Body ground

Always

10 kΩ or higher

18 (THO1) - Body ground

Always

10 kΩ or higher

Text in Illustration

*a

Component without harness connected:

(Transmission Wire)

HINT:

If the resistance is out of the specified range with the ATF temperature shown in the table below, the driveability of the vehicle may decrease.

ATF Temperature

Specified Condition

10°C (50°F)

5 to 8 kΩ

25°C (77°F)

2.5 to 4.5 kΩ

110°C (230°F)

0.22 to 0.28 kΩ

OK

REPLACE TCM

NG

2.

INSPECT ATF TEMPERATURE SENSOR

(a) Disconnect the transmission wire connector from the ATF temperature sensor assembly.

(b) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

1 (THO1) - 2 (E2)

Always

79 Ω to 156 kΩ

1 (THO1) - Body ground

Always

10 kΩ or higher

2 (E2) - Body ground

Always

10 kΩ or higher

Text in Illustration

*a

Component without harness connected:

(ATF Temperature Sensor)

HINT:

If the resistance is out of the specified range with the ATF temperature shown in the table below, the driveability of the vehicle may decrease.

ATF Temperature

Specified Condition

10°C (50°F)

5 to 8 kΩ

25°C (77°F)

2.5 to 4.5 kΩ

110°C (230°F)

0.22 to 0.28 kΩ

OK

REPLACE TRANSMISSION WIRE

NG

REPLACE ATF TEMPERATURE SENSOR ASSEMBLY