INSPECTION
PROCEDURE
1. INSPECT THERMOSTAT
(a) Inspect the thermostat.
HINT:
The valve opening temperature is inscribed on the thermostat.
|
|
(b) Immerse the thermostat in water and gradually heat the water.
|
|
(c) Check the valve opening temperature.
Standard valve opening temperature:
80 to 84°C (176 to 183°F)
If the valve opening temperature is not as specified, replace the thermostat.
(d) Check the valve lift.
Standard valve lift:
10 mm (0.394 in.) or more at 95°C (203°F)
If the valve lift is not as specified, replace the thermostat.
|
|
(e) Check that the valve is fully closed when the thermostat is at low temperatures (below 77°C (171°F)).
If it is not fully closed, replace the thermostat.
|