Last Modified: 04-05-2023 6.11:8.1.0 Doc ID: RM100000000VIFP
Model Year Start: 2016 Model: Sienna Prod Date Range: [12/2015 - 08/2016]
Title: 2GR-FE COOLING: THERMOSTAT: INSPECTION; 2016 MY Sienna [12/2015 - 08/2016]

INSPECTION

PROCEDURE

1. INSPECT THERMOSTAT

(a) Inspect the thermostat.

HINT:

The valve opening temperature is inscribed on the thermostat.

(b) Immerse the thermostat in water and gradually heat the water.

(c) Check the valve opening temperature.

Standard valve opening temperature:

80 to 84°C (176 to 183°F)

If the valve opening temperature is not as specified, replace the thermostat.

(d) Check the valve lift.

Standard valve lift:

10 mm (0.394 in.) or more at 95°C (203°F)

If the valve lift is not as specified, replace the thermostat.

(e) Check that the valve is fully closed when the thermostat is at low temperatures (below 77°C (171°F)).

If it is not fully closed, replace the thermostat.