Last Modified: 04-05-2023 6.11:8.1.0 Doc ID: RM100000000VIEK
Model Year Start: 2016 Model: Sienna Prod Date Range: [12/2015 - 08/2016]
Title: 2GR-FE EMISSION CONTROL: PURGE VALVE: INSPECTION; 2016 MY Sienna [12/2015 - 08/2016]

INSPECTION

PROCEDURE

1. INSPECT PURGE VSV

(a) Measure the resistance according to the value(s) in the table below.

Text in Illustration

*a

Component without harness connected

(Purge VSV)

Standard Resistance:

Tester Connection

Condition

Specified Condition

1 - 2

20°C (68°F)

23 to 26 Ω

If the result is not as specified, replace the purge VSV.

(b) Check operation of the purge VSV.

(1) Check that air does not flow from port E to port F.

Text in Illustration

*1

Port F

*2

Port E

*a

Air

(2) Apply battery voltage across the terminals.

Text in Illustration

*1

Port F

*2

Port E

*a

Component without harness connected

(Purge VSV)

*b

Air

(3) Check that air flows from port E to port F.