DESCRIPTIONThis circuit opens and closes the intake air control valve (intake air surge tank assembly) in response to changes in the engine load in order to increase the intake efficiency using the acoustic control induction system. When the engine speed is between 0 and 4300 rpm and the throttle valve opening angle is 60° or more, the ECM supplies current to the actuator (on status), to close the intake air control valve. Under other conditions, the VSV is usually off and the intake air control valve is open. WIRING DIAGRAMCAUTION / NOTICE / HINTNOTICE: Inspect the fuses for circuits related to this system before performing the following inspection procedure. PROCEDURE
(a) Connect the Techstream to the DLC3. (b) Turn the ignition switch to ON. (c) Turn the Techstream on. (d) Enter the following menus: Powertrain / Engine / Active Test / Activate the VSV for Intake Control. (e) Check if operating noise can be heard when operating the intake air control valve (intake air surge tank assembly) using the Techstream. OK: Operating noise can be heard.
(b) Apply battery voltage between the terminals of the intake air control valve connector. Text in Illustration
(c) Check the intake air control valve (intake air surge tank assembly) operation. OK: Operating noise can be heard.
(b) Turn the ignition switch to ON. (c) Measure the voltage according to the value(s) in the table below. Standard Voltage:
Text in Illustration
(a) Disconnect the intake air control valve (intake air surge tank assembly) connector. (b) Disconnect the ECM connector. (c) Measure the resistance according to the value(s) in the table below. Standard Resistance (Check for Open):
Standard Resistance (Check for Short):
|