Last Modified: 04-05-2023 |
6.11:8.1.0 |
Doc ID: RM100000000VI9I |
Model Year Start: 2016 |
Model: Sienna |
Prod Date Range: [12/2015 - 08/2016] |
Title: 2GR-FE (ENGINE CONTROL): HEATED OXYGEN SENSOR: INSPECTION; 2016 MY Sienna [12/2015 - 08/2016] |
INSPECTION
PROCEDURE
1. INSPECT NO. 2 OXYGEN SENSOR (for Bank 1 Sensor 2)
(a) Measure the resistance according to the value(s) in the table below.
Text in Illustration
*a
|
Component without harness connected
(No. 2 Oxygen Sensor)
|
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
1 (HT1B) - 2 (+B)
|
20°C (68°F)
|
11 to 16 Ω
|
1 (HT1B) - 4 (E2)
|
Always
|
10 kΩ or higher
|
If the result is not as specified, replace the No. 2 oxygen sensor.
|
|
2. INSPECT OXYGEN SENSOR (for Bank 2 Sensor 2)
(a) Measure the resistance according to the value(s) in the table below.
Text in Illustration
*a
|
Component without harness connected
(Oxygen Sensor)
|
Standard Resistance:
Tester Connection
|
Condition
|
Specified Condition
|
1 (HT2B) - 2 (+B)
|
20°C (68°F)
|
11 to 16 Ω
|
1 (HT2B) - 4 (E2)
|
Always
|
10 kΩ or higher
|
If the resistance is not as specified, replace the oxygen sensor.
|
|
|