(a) Measure the resistance according to the value(s) in the table below.
Text in Illustration
*a
|
Component without harness connected
(Air Fuel Ratio Sensor)
|
*b
|
for Bank 1
|
*c
|
for Bank 2
|
Standard Resistance (for Bank 1):
Tester Connection
|
Condition
|
Specified Condition
|
1 (HA1A) - 2 (+B)
|
20°C (68°F)
|
1.6 to 3.2 Ω
|
1 (HA1A) - 4 (A1A-)
|
Always
|
10 kΩ or higher
|
Standard Resistance (for Bank 2):
Tester Connection
|
Condition
|
Specified Condition
|
1 (HA2A) - 2 (+B)
|
20°C (68°F)
|
1.6 to 3.2 Ω
|
1 (HA2A) - 4 (A2A-)
|
Always
|
10 kΩ or higher
|
If the result is not as specified, replace the air fuel ratio sensor.
|