Connector Part Information
  | 
Terminal Type ID  | Terminated Lead  | Diagnostic Test Probe  | Terminal Removal Tool  | 
|---|---|---|---|
I  | Not required  | No Tool Required  | Not Available  | 
Pin  | Size  | Color  | Circuit  | Function  | Terminal Type ID  | Option  | 
|---|---|---|---|---|---|---|
1  | —  | —  | —  | Not Occupied  | —  | —  | 
2  | 0.35  | YE  | 3165  | Mode Door Actuator Control 1  | I  | —  | 
3  | 0.35  | WH/RD  | 3166  | Mode Door Actuator Control 2  | I  | —  | 
4  | 0.35  | GY/BN  | 3167  | Mode Door Actuator Control 3  | I  | —  | 
5  | 0.35  | GN/WH  | 3168  | Mode Door Actuator Control 4  | I  | —  | 
6 - 8  | —  | —  | —  | Not Occupied  | —  | —  | 
9  | 0.35  | BK  | 1791  | Air Temperature Door Low Reference  | I  | —  | 
10  | —  | —  | —  | Not Occupied  | —  | —  | 
11  | 0.35  | GN  | 3169  | Air Temperature Door Actuator Control 1  | I  | —  | 
12  | 0.35  | WH/PK  | 3170  | Air Temperature Door Actuator Control 2  | I  | —  | 
13  | 0.35  | GY/RD  | 3171  | Air Temperature Door Actuator Control 3  | I  | —  | 
14  | 0.35  | RD/BK  | 3172  | Air Temperature Door Actuator Control 4  | I  | —  | 
15  | 0.75  | OG  | 7572  | HVAC Door Actuator Control  | I  | —  | 
16  | 0.35  | GY  | 3173  | Air Inlet Door Actuator Control 1  | I  | —  | 
17  | 0.35  | BU/WH  | 3174  | Air Inlet Door Actuator Control 2  | I  | —  | 
18  | 0.35  | BN/GN  | 3175  | Air Inlet Door Actuator Control 3  | I  | —  | 
19  | 0.35  | RD/GN  | 3176  | Air Inlet Door Actuator Control 4  | I  | —  | 
20  | 0.35  | BK/GY  | 6137  | Air Conditioning Evaporator Temperature Sensor Signal  | I  | —  |