Note:
- Always verify the module has the newest software available before replacing the module.
- Ensure the programming tool is equipped with the latest software and is securely connected to the data link connector. If there is an interruption during programming, programming failure or control module damage may occur.
- Stable battery voltage is critical during programming. Any fluctuation, spiking, over voltage or loss of voltage will interrupt programming. When required install the EL-49642 SPS Programming Support Tool to maintain system voltage. If not available, connect a fully charged 12 V jumper or booster pack disconnected from the AC voltage supply. DO NOT connect
a battery charger.
- Turn OFF or disable systems that may put a load on the vehicles battery such as; interior lights, exterior lights (including daytime running lights), HVAC, radio, etc.
- During the programming procedure, follow the SPS prompts for the correct ignition switch position.
- Clear DTCs after programming is complete. Clearing powertrain DTCs will set the Inspection/Maintenance (I/M) system status indicators to NO.
- Anytime the B174W Frontview Camera – Windshield is removed from its mount, the Front View Camera Module Learn procedure must be performed.
Following Replacement of Windshield
The B174W Frontview Camera – Windshield must be calibrated, refer to Front View Camera Module Learn.
Programing an Existing or New Control Module
To program a replacement or an existing B174W Frontview Camera – Windshield, perform the following procedure:
- Access the Service Programming System (SPS) and follow the on-screen instructions.
- On the SPS Supported Controllers screen, select B174W Frontview Camera – Windshield Programming and follow the on-screen instructions.
- On the SPS Supported Controllers screen, select B174W Frontview Camera – Windshield Configuration and follow the on-screen instructions.
- Clear DTCs
Note: After programming, a current DTC may be set in the B174W Frontview Camera – Windshield that is unable to be cleared. This is normal and an indicator that the B174W Frontview Camera – Windshield is in learn mode.
- Following B174W Frontview Camera – Windshield replacement and/or reprogramming, the module must be calibrated. Refer to Front View Camera Module Learn.
Unsuccessful Programming Recovery
In the event of an interrupted or unsuccessful programming event, perform the following steps:
- DO NOT turn the ignition OFF. Ensure that all B174W Frontview Camera – Windshield, DLC and programming tool connections are secure and the TIS terminal operating software is up to date.
- Attempt to reprogram the B174W Frontview Camera – Windshield.
- If the B174W Frontview Camera – Windshield can still not be programmed, turn the ignition OFF for at least one minute.
- Turn the ignition ON and attempt to reprogram the B174W Frontview Camera – Windshield. The B174W Frontview Camera – Windshield should program.
- If the B174W Frontview Camera – Windshield still cannot be programmed, replace the B174W Frontview Camera – Windshield.