High Pressure Fuel Variable Reset
Diagnostic InstructionsDescription

This procedure resets the control module learned values of the component/system:G18 High Pressure Fuel Pump

When to Perform the Procedure

Note: Failure to perform this procedure may result in poor system performance, DTCs being set, or customer dissatisfaction.

Perform this procedure when the following component has been serviced:

  • G18 High Pressure Fuel Pump—Replaced
  • Q17 Fuel Injector—Replaced
  • Q18 Fuel Pressure Regulator—Replaced
  • Fuel Rail—Replaced
Conditions for Running the Procedure

Ignition=On

Reference Information

Scan Tool Reference

Control Module References

With Scan ToolRepair Instructions

Perform the Diagnostic Repair Verification after completing the repair:Diagnostic Repair Verification