For equivalent regional tools, refer to Special Tools.
Terminal Removal Procedure
Locate the connector position assurance (CPA) on the connector body and pull the CPA out. The CPA is on the wire harness side of connector.
Disconnect the connector from the component.
Use a small flat-bladed tool to gently pry off the dress cover by inserting the tool under the cover opposite the harness side and prying up.
Remove the cover.
Using a small flat-bladed tool, push on the side of the nose piece retainer while pushing the nose piece forward with your thumb. This will release the terminal position assurance (TPA).
Insert the J-38125-12A toolinto the corresponding terminal release cavity. The release cavities are the 2 center rows of cavities on one half of the connector.
Pressing the J-38125-12A toolin the release cavity of the terminal you are removing, gently pull the wire out of the back of the connector. Always remember never use force when pulling a terminal out of a connector.