Diagnostic Instructions
DTC Descriptors
A/C Evaporator Temperature Sensor Circuit Short to Ground
A/C Evaporator Temperature Sensor Circuit High Voltage/Open
Diagnostic Fault Information
Circuit  | Short to Ground  | Open/High Resistance  | Short to Voltage  | Signal Performance  | 
|---|---|---|---|---|
Evaporator Temperature Sensor Signal  | B3933 02  | B3933 05  | B3933 05  | —  | 
Low Reference  | —  | B3933 05  | —  | —  | 
Circuit Description
The evaporator air temperature sensor is a 2-wire negative temperature coefficient thermistor. The HVAC control module provides a low reference circuit and signal circuit. The HVAC control module determines the voltage drop across the sensor, which is proportional to temperature. As the air temperature increases, the sensor resistance decreases and the voltage signal decreases. As the air temperature decreases, the sensor resistance increases and the voltage signal increases.
Conditions for Running the DTC
The ignition is ON.
Conditions for Setting the DTC
The HVAC control module detects the sensor signal out of range. The signal voltage is less than 0.1 V or greater than 4.9 V for more than 50 ms.
Action Taken When the DTC Sets
The system operates using a default value.
Conditions for Clearing the DTC
Reference Information
Schematic ReferenceConnector End View ReferenceMaster Electrical Component List
Description and OperationManual HVAC Description and Operation
Electrical Information ReferenceControl Module References for scan tool information
Circuit/System Testing
Replace the K33 HVAC Control Module.
Repair Instructions
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.